1.Immortalization of human fallopian tube epithelial cells
Wen GAO ; Rongyu ZANG ; Yan WANG ; Lina YANG ; Yang LIU ; Zihao QI ; Sheng YIN ; Gong YANG
China Oncology 2013;(4):241-247
10.3969/j.issn.1007-3969.2013.04.00X
2.Analysis of sonography videourodynamic studies in characteristics of patients with female bladder outlet obstruction
Rongyu TANG ; Ning XIAO ; Huasheng ZHAO ; Lianhua CHEN ; Qi TANG ; Weijian LIN ; Jianfeng WANG
Chinese Journal of Urology 2021;42(5):385-387
In this study, sonography video urodynamic studies (SVUDS), which combined synchronically urodynamic studies with trans-perineal and trans-abdominal sonography, were used to detect female bladder outlet obstruction (FBOO). The dynamic changes of urethra and surrounding pelvic floor structure during storage and voiding phase were observed by SVUDS and the causes of FBOO were analyzed. And the findings were as follows: 13 patients showed organ prolapse, there was an urethral angulation deformity during urination; 5 cases had abnormal urination as the urethral opening was not good in the middle of urination period; 4 cases had urethral stricture, as the proximal end of the obstruction dilated during urination, and the obstruction site showed no relaxation; 1 case had primary bladder neck obstruction with an incomplete opening of the bladder neck during urination; 3 cases had idiopathic bladder outlet obstruction and the sphincter of bladder neck and urethra opened well during urination.
3.Suggestions for checking quality of occupational health examination
Chinese Journal of Industrial Hygiene and Occupational Diseases 2021;39(3):226-227
To project the basis of occupational health examination quality assessment, and put forward advices for cheking: the quality and safety of occupational health examination, assessment requirements, the key points on-site, utilization of the quality assessment results. Total quality control (TQC) contains basic quality, link quality, final quality and front, middle, back of the quality in occupational health examination.
4.Suggestions for checking quality of occupational health examination
Chinese Journal of Industrial Hygiene and Occupational Diseases 2021;39(3):226-227
To project the basis of occupational health examination quality assessment, and put forward advices for cheking: the quality and safety of occupational health examination, assessment requirements, the key points on-site, utilization of the quality assessment results. Total quality control (TQC) contains basic quality, link quality, final quality and front, middle, back of the quality in occupational health examination.
5.Establishment of the quality management system for occupational diseases diagnosis
Peng LI ; Dawei LIN ; Yan ZHAO ; Jianfang ZOU ; Rongyu QI
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(4):298-301
The quality management system of occupational diseases diagnosis is belonged to one part of the hospital quality management system. It must be adhered to the quality management concept of comprehensive, full staff and whole process. To establish and improve the quality management system should be included: (1) Formulated a quality management manual for occupational disease diagnosis, including organization construction, rules and regulations, responsibilities, work flow, operating procedures and clinical pathways, standard instrument, etc. (2) Managed the document of occupational diseases diagnosis. (3) The continuous improvement of quality management. The quality management of occupational diseases diagnosis focuses on the mastery and implementation of the manual by employees, which is reflected in the continuous improvement of daily work, internal assessment and external assessment.
6.Establishment of the quality management system for occupational diseases diagnosis
Peng LI ; Dawei LIN ; Yan ZHAO ; Jianfang ZOU ; Rongyu QI
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(4):298-301
The quality management system of occupational diseases diagnosis is belonged to one part of the hospital quality management system. It must be adhered to the quality management concept of comprehensive, full staff and whole process. To establish and improve the quality management system should be included: (1) Formulated a quality management manual for occupational disease diagnosis, including organization construction, rules and regulations, responsibilities, work flow, operating procedures and clinical pathways, standard instrument, etc. (2) Managed the document of occupational diseases diagnosis. (3) The continuous improvement of quality management. The quality management of occupational diseases diagnosis focuses on the mastery and implementation of the manual by employees, which is reflected in the continuous improvement of daily work, internal assessment and external assessment.
7.Diagnostic value of a combined serology-based model for minimal hepatic encephalopathy in patients with compensated cirrhosis
Shanghao LIU ; Hongmei ZU ; Yan HUANG ; Xiaoqing GUO ; Huiling XIANG ; Tong DANG ; Xiaoyan LI ; Zhaolan YAN ; Yajing LI ; Fei LIU ; Jia SUN ; Ruixin SONG ; Junqing YAN ; Qing YE ; Jing WANG ; Xianmei MENG ; Haiying WANG ; Zhenyu JIANG ; Lei HUANG ; Fanping MENG ; Guo ZHANG ; Wenjuan WANG ; Shaoqi YANG ; Shengjuan HU ; Jigang RUAN ; Chuang LEI ; Qinghai WANG ; Hongling TIAN ; Qi ZHENG ; Yiling LI ; Ningning WANG ; Huipeng CUI ; Yanmeng WANG ; Zhangshu QU ; Min YUAN ; Yijun LIU ; Ying CHEN ; Yuxiang XIA ; Yayuan LIU ; Ying LIU ; Suxuan QU ; Hong TAO ; Ruichun SHI ; Xiaoting YANG ; Dan JIN ; Dan SU ; Yongfeng YANG ; Wei YE ; Na LIU ; Rongyu TANG ; Quan ZHANG ; Qin LIU ; Gaoliang ZOU ; Ziyue LI ; Caiyan ZHAO ; Qian ZHAO ; Qingge ZHANG ; Huafang GAO ; Tao MENG ; Jie LI ; Weihua WU ; Jian WANG ; Chuanlong YANG ; Hui LYU ; Chuan LIU ; Fusheng WANG ; Junliang FU ; Xiaolong QI
Chinese Journal of Laboratory Medicine 2023;46(1):52-61
Objective:To investigate the diagnostic accuracy of serological indicators and evaluate the diagnostic value of a new established combined serological model on identifying the minimal hepatic encephalopathy (MHE) in patients with compensated cirrhosis.Methods:This prospective multicenter study enrolled 263 compensated cirrhotic patients from 23 hospitals in 15 provinces, autonomous regions and municipalities of China between October 2021 and August 2022. Clinical data and laboratory test results were collected, and the model for end-stage liver disease (MELD) score was calculated. Ammonia level was corrected to the upper limit of normal (AMM-ULN) by the baseline blood ammonia measurements/upper limit of the normal reference value. MHE was diagnosed by combined abnormal number connection test-A and abnormal digit symbol test as suggested by Guidelines on the management of hepatic encephalopathy in cirrhosis. The patients were randomly divided (7∶3) into training set ( n=185) and validation set ( n=78) based on caret package of R language. Logistic regression was used to establish a combined model of MHE diagnosis. The diagnostic performance was evaluated by the area under the curve (AUC) of receiver operating characteristic curve, Hosmer-Lemeshow test and calibration curve. The internal verification was carried out by the Bootstrap method ( n=200). AUC comparisons were achieved using the Delong test. Results:In the training set, prevalence of MHE was 37.8% (70/185). There were statistically significant differences in AMM-ULN, albumin, platelet, alkaline phosphatase, international normalized ratio, MELD score and education between non-MHE group and MHE group (all P<0.05). Multivariate Logistic regression analysis showed that AMM-ULN [odds ratio ( OR)=1.78, 95% confidence interval ( CI) 1.05-3.14, P=0.038] and MELD score ( OR=1.11, 95% CI 1.04-1.20, P=0.002) were independent risk factors for MHE, and the AUC for predicting MHE were 0.663, 0.625, respectively. Compared with the use of blood AMM-ULN and MELD score alone, the AUC of the combined model of AMM-ULN, MELD score and education exhibited better predictive performance in determining the presence of MHE was 0.755, the specificity and sensitivity was 85.2% and 55.7%, respectively. Hosmer-Lemeshow test and calibration curve showed that the model had good calibration ( P=0.733). The AUC for internal validation of the combined model for diagnosing MHE was 0.752. In the validation set, the AUC of the combined model for diagnosing MHE was 0.794, and Hosmer-Lemeshow test showed good calibration ( P=0.841). Conclusion:Use of the combined model including AMM-ULN, MELD score and education could improve the predictive efficiency of MHE among patients with compensated cirrhosis.