1.Analysis of pathogenic bacteria, drug resistance and risk factors in patients with vaginitis in Zhangjiakou area
Chinese Journal of Primary Medicine and Pharmacy 2013;20(12):1842-1844
Objective To investigate characteristics of pathogen distribution and drug resistance,and to analyze risk factors of the infection in patients with vaginitis in Zhangjiakou area.Methods Vaginal secretion specimen from 368 patients with vaginitis were collected and then processed by germiculture,identification and drug sensitivity tests.Risk factors of infection were identified among age,marriage history,first sexual intercourse age,education,childbearing history,abortion history,contraception,householding et al by single factor x2 analysis and Logistic regression analysis.Results Blastomyces albicans,ureaplasma urealyticum,escherichia coli,enterococcus faecalis and gardner vaginal bacteria listed top 5 of composition of infection rate in patients with vaginitis.Blastomyces albicans was sensitive to multiple antifungal agent; escherichia coli and gardner vaginal bacteria were resistant to multiple antibiotics but sensitive to imipenem;ureaplasma urealyticum was resistant to multiple antibiotics but sensitive to josamycin and clarithromycin;enterococcus faecalis was strongly resisted to SMZ and erythromycin.Age ranging from 31 ~40y,application of IUD,positive abortion history and first sex intercourse before 23y were identified as risk factors for infection in patients with vaginitis.Conclusion Infection characteristics and risk factors could be utilized as indicators in considering treatment programs for patients with vaginitis.
2.Electrocardiographic characteristics and radiofrequency catheter ablation of ventricular tachycardia and frequent ventricular premature contractions originating from left ventricular outflow tract
Hong CHEN ; Weiwei ZHANG ; Rongqin LI ; Zhanquan LI ; Ran CUI
Chinese Journal of Primary Medicine and Pharmacy 2008;15(7):1075-1076
Objective To investigate the electrocardiographic(ECG) characteristics and assess the safety of radiofrequency catheter ablation (RFCA) of ventricular tachyeardia (VT), and frequent ventricular premature con- tractious(VPCs) originating from left ventricular outflow tract(LVOT). Methods Twelve-lead ECG analysis and RFCA were performed in 9 patient with VT or VPCs originating from LVOT. Results The sites to be successfully ablated were in left valsalva sinus in 6 patients,and subaortic valve in 3 patient. ECG revealed tall R wave in leads Ⅱ, Ⅲ ,aVF, V5 and V6. QS morphology in both leads aVR and aVL,QS morphology in lead Ⅰ in most cases. R wave in lead Ⅰ was relative tall, the R/S wave amplitude in lead V1 was over 0.62 ,and precordia R wave transition was irregular. All 9 patients were successfully ablated. No death or recurrenced case during follow-up. Conclusion Ventricular taehycardia and frequent ventricular premature rcontractions originating from left ventricutar outflow tract could be known by some specific ECG characteristics and could be radically treated safely by RFCA.
3.Artificial hydrothorax combined with one-lung ventilation to aid percutaneous ablation treatment of liver carcinoma in the hepatic dome
Guanghui GUO ; Erjiao XU ; Rongqin ZHENG ; Qingjin ZENG ; Kai LI
Chinese Journal of Ultrasonography 2015;24(11):959-962
Objective To evaluate the clinical value of artificial hydrothorax combined with one-lung ventilation to aid ablation treatment of liver carcinoma in the hepatic dome.Methods Twenty-one patients with liver carcinoma located in the hepatic dome and affected by the lung gas were enrolled.Double lumen endobronchial intubation anesthesia was used and thoracical tube was used to apply artificial pleural effusion.The lesions'ultrasound image were recorded for the patients without artificial hydrothorax,or with artificial hydrothorax only and artificial hydrothorax combined with one-lung ventilation.Ultrasound images were reviewed and scored as 1-5 according to the clarity and completeness of the lesion.Ablation efficacy and adverse reactions were recorded in the follow-up.Results Twenty-one patients were successfully applied artificial hydrothorax and one lung ventilation.The average normal saline used for artificial hydrothorax were (738± 260)ml.The ultrasound score for not using artificial hydrothorax,using artificial hydrothorax only and artificial hydrothorax combined with one lung ventilation were 1.13 ± 0.35 (1-2),3.00 ± 0.85 (2-5) and 4.53 ± 0.64(3-5),respectively,statistical difference was found between each method(P <0.05).Artificial hydrothorax combined with one-lung ventilation had much higher ultrasound score than the other 2 methods.No complication related to artificial hydrothorax or one-lung ventilation was found.CT/MRI at one month after ablation showed that all the lesions were completely ablated.In the follow-up for 2-14 months on average,1 case of local tumor progression and 1 case of intrahapetic relapse were found.Conclusions Artificial hydrothorax combine one-lung ventilation could effectively enhance ultrasound image for the lesions in the dome whose acoustic window was affected by lung gas.
4.Analysis of the Application of Second Class of Psychotropic Drugs in Outpatient Department of Our Hospi-tal during 2012-2015
Junqing ZHANG ; Rongqin LI ; Niansheng WANG ; Gong ZHANG
China Pharmacy 2016;27(17):2323-2325
OBJECTIVE:To provide reference for rational use of second class of psychotropic drugs in the clinic. METHODS:The second class of psychotropic drugs in outpatient department of our hospital during 2012-2015 were analyzed retrospectively in respects of the number of common drugs prescription,distribution of gender/age/disease diagnosis,DDDs and DUI,etc. RE-SULTS:During 2012-2015,second class of psychotropic drugs in outpatient department of our hospital accounted for 25.09%of to-tal prescription amout. The drugs with high use frequency were alprazolam,clonazepam,lorazepam and estazolam,accounting for 93.10% of total prescription amount of second class of psychotropic drugs. The proportion of male to female was 1∶1.50;the pa-tients aged 19-35 years old took up the biggest proportion,accounting for 34.62%. The proportion of schizophrenia prescription was the highest,accounting for 45.17%. DDDs of alprazolam was the highest,being 742 141.67;its DUI was 1.075;DUI of oth-er drugs was lower than 1.0. CONCLUSIONS:The use of second class of psychotropic drugs is basically reasonable in our hospi-tal. Guiding principles of Clinical Application of Psychotropic Drugs should be implemented strictly and continously to avoid abuse of second class of psychotropic drugs.
5.Comparative analysis on the performance evaluation of hospitals between China and some countries
Rongqin JIANG ; Jingxian LI ; Dan HU ; Aichen GE ; Jiaying CHEN
Chinese Journal of Health Policy 2016;9(12):62-67
This study aimed at comparing the United States, Britain, Australia, the Netherlands and China’s national performance evaluation, and sum up the experience to provide a theoretical basis for the China’s development of hospital performance evaluation system. The study found that China needs to consider the patient's perspective, to establish a fixed third-party performance evaluation agencies, establish an effective incentive mechanism and feedback mechanism and combine a variety of assessment methods in the development of hospital performance evaluation index system.
6.The reasons of focal liver lesions that difficult to detect by conventional ultrasound analysed by ultrasound-CT/MR fusion imaging
Shufang YUAN ; Kai LI ; Rongqin ZHENG ; Zhongzhen SU ; Erjiao XU
Chinese Journal of Ultrasonography 2014;23(3):235-238
Objective To analyze the reasons of focal liver lesions that difficult to detect by conventional ultrasound ultrasound-CT/MR fusion imaging.Methods 101 lesions which were confirmed by pathology or clinical diagnosis standards were recruited in the research.All of them were difficult to detect by conventional ultrasound but CT/MR display clearly.Ultrasound-CT/MR fusion imaging was used to observe the size,location and internal echo of the lesions,as well as the background of the surrounding liver parenchyma.Results All cases were successfully registrated,the registration time were 2-6min [(4.1 ±0.6)min].For these 101 lesions,93.1%(94/101) of which the diameter ≤20 mm,56.4% (57/101) were located in hepatic segments near the diaphragm (such as S2,S4,S7,S8),78.2% (79/101) were internal isoecho,and 79.2%(80/101) in the background of liver cirrhosis.Conclusions The important reasons that focal liver lesions detected difficult by conventional ultrasound includes:lesion size,location,internal echo and the hepatic background.
7.Role of teaching resource database in blood disease testing technology teaching reform
Hongyan LI ; Zhenjiang HOU ; Qian XU ; Rongqin DAI
Chinese Journal of Medical Education Research 2013;(7):690-692
This paper introduced the necessity, background, principle, content, function of construction of teaching resource database of blood disease testing technology and its role played in teach-ing reform. Construction of teaching resource database made up for the insufficiency of blood disease test-ing technology in teaching time and resource, explored more scientific learning mode and teaching meth-ods and strengthened the cooperation between part-time teachers and professional teachers of blood dis-ease testing technology courses.
8.Experimental study of 3DUS-US single-modality automatic image fusion technology based on electromagnetic positioning
Liujun LI ; Xuqi HE ; Erjiao XU ; Kai LI ; Jiaxin CHEN ; Rongqin ZHENG ; Zhongzhen SU
Chinese Journal of Ultrasonography 2015;(7):618-621
Objective To evaluate the feasibility and accuracy of three-dimensional ultrasound-ultrasound (3DUS-US)automatic image fusion technology based on electromagnetic positioning.Methods The experimental phantom was constructed to acquire ultrasonic images by agarose gel and additives,which was used as the experimental object.3DUS imaging with free-hand and real-time ultrasound imaging automatic registrations were performed based on electromagnetic positioning.To investigate the effect of 3DUS-US image fusion under different scanning speed by free-hand,the fast and slow groups were designed. In addition,a junior operator and a senior operator performed 3DUS-US automatic registrations,and recorded the operating time and registration error,respectively.The repeatability between two operators was analyzed.Results The macroscopic appearance,stability and ultrasonic image of the phantom met the demand of this research.The success rate of 3DUS-US automatic image fusion technology was 100%(40/40).The slow group's registration error distance was (1 .44 ± 0.64)mm,which was obviously lower than the fast group's (2.56±0.53)mm,the difference was statistically significant (P <0.001).There were no statistically differences of the registration error and operating time between the two operators (P =0.508,P = 0.5 1 7 ).Conclusions The technology of 3DUS-US automatic registration based on electromagnetic positioning was feasible and accurate,which is worth applying into the clinical treatment.
9.A preliminary study of three-dimensional ultrasound images automatic registration based on hepatic vessel
Zhongzhen SU ; Liujun LI ; Kai LI ; Erjiao XU ; Jue WANG ; Rongqin ZHENG
Chinese Journal of Ultrasonography 2014;23(10):865-868
Objective To evaluate the feasibility and accuracy of three-dimensional ultrasound (3DUS) automatic image fusion based on hepatic vessel in clinical application.Methods Forty pairs of 3D ultrasound volumetric images from 10 healthy volunteers were acquired and enrolled in the study,including 10 pairs of each following lobe of the liver:left lateral lobe,left medial lobe,right anterior lobe and right posterior lobe.3DUS automatic registrations were performed based on hepatic vessel.The technical successful rate and accuracy of the image fusion using the 3DUS data from four hepatic lobes were observed and compared.Results Thirty-six pairs of volumetric data were successfully fused together by automatic registration.The technical successful rate was 90% (36/40) and the registration error distance was 1.48 mm (0.98-2.76 mm).There were no statistical differences in the successful rate for the four different hepatic lobes (P =0.891),but the registration error of right anterior lobe was less than left lateral lobe of liver (P =0.014).Conclusions The new technology of 3DUS automatic registration based on hepatic vessel was feasible and reliable,and it has a wide prospect in future clinical application.
10.Planning of the hepatocellular carcinoma's ablation by three-dimensional ultrasound:a preliminary study
Peishan GUAN ; Kai LI ; Rongqin ZHENG ; Liujun LI ; Zhongzhen SU ; Erjiao XU ; Jue WANG
Chinese Journal of Ultrasonography 2015;(5):407-411
Objective To discusse the feasibility and application value of the computer-assisted liver cancer ablation planning based on the three dimensional ultrasound.Methods Forty three-dimensional ultrasound images of 39 patients with 40 tumors'maximum diameter between 21 to 70 mm were collected and then acquired image segmentation and visualzation.The computer-assisted liver cancer ablation planning based on three dimensional ultrasound was comparied with the artificial ablation planning based on two dimensional ultrasound to find out the differences in the success rate,damage rate,time-consuming and the number of insertions between these two methods.Results Compared with the artificial ablation planning based on two dimensional ultrasound,the computer-assisted liver cancer ablation planning had a higher success rate(92.31% vs 53.85%,P =0.000),lower damage rate(7.50% vs 25.00%,P =0.034),shorter time-consuming(44.0 s vs 263.0 s,P =0.000)and less insersion times(3 vs 4,P =0.009).Conclusions The computer-assisted liver cancer ablation planning based on three dimensional ultrasound is more efficient and safety than the traditional way.