1.Effect of ultrasonic agitation on push-out bond strength and adaptation of root-end filling materials.
Murilo Priori ALCALDE ; Rodrigo Ricci VIVAN ; Marina Angélica MARCIANO ; Jussaro Alves DUQUE ; Samuel Lucas FERNANDES ; Mariana Bailo ROSSETO ; Marco Antonio Hungaro DUARTE
Restorative Dentistry & Endodontics 2018;43(2):e23-
OBJECTIVES: This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. MATERIALS AND METHODS: Sixty maxillary canines were divided into 6 groups (n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. RESULTS: Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA (p < 0.05). US improved the push-out bond strength for all the cements (p < 0.05). CONCLUSIONS: The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.
Calcium
;
Dentin
;
Dihydroergotamine*
;
Endodontics
;
Hand
;
Microscopy, Electron, Scanning
;
Miners
;
Pemetrexed
;
Retrograde Obturation
;
Tooth
;
Transducers
;
Ultrasonics*
;
Ultrasonography
2.Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canal
Pedro de Souza DIAS ; Augusto Shoji KATO ; Carlos Eduardo da Silveira BUENO ; Rodrigo Ricci VIVAN ; Marco Antonio Hungaro DUARTE ; Pedro Henrique Souza CALEFI ; Rina Andréa PELEGRINE
Restorative Dentistry & Endodontics 2023;48(1):e4-
Objectives:
This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG).
Materials and Methods:
A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure.Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%.
Results:
The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue.
Conclusions
Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments’ clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.
3.Impact of different agitation methods on smear layer cleaning of mesial canals with accentuated curvature
Abel Teves CORDOVA ; Murilo Priori ALCALDE ; Michel Espinosa KLYMUS ; Leonardo Rigoldi BONJARDIM ; Rodrigo Ricci VIVAN ; Marco Antonio Hungaro DUARTE
Restorative Dentistry & Endodontics 2024;49(2):e12-
Objectives:
This study evaluated the impact of different methods of irrigant agitation on smear layer removal in the apical third of curved mesial canals of 3 dimensionally (D) printed mandibular molars.
Materials and Methods:
Sixty 3D-printed mandibular second molars were used, presenting a 70° curvature and a Vertucci type II configuration in the mesial root. A round cavity was cut 2 mm from the apex using a trephine of 2 mm in diameter, 60 bovine dentin disks were made, and a smear layer was formed. The dentin disks had the adaptation checked in the apical third of the teeth with wax. The dentin disks were evaluated in environmental scanning electron microscope before and after the following irrigant agitation methods:G1(PIK Ultrasonic Tip), G2 (Passive Ultrasonic Irrigation with Irrisonic– PUI), G3 (Easy Clean), G4 (HBW Ultrasonic Tip), G5 (Ultramint X Ultrasonic tip), and G6 (conventional irrigation-CI) (n = 10). All groups were irrigated with 2.5% sodium hypochlorite and 17% ethylenediaminetetraacetic acid.
Results:
All dentin disks were 100% covered by the smear layer before treatment, and all groups significantly reduced the percentage of the smear layer after treatment. After the irrigation protocols, the Ultra-X group showed the lowest coverage percentage, statistically differing from the conventional, PIK, and HBW groups (p < 0.05). There was no significant difference among Ultramint X, PUI-Irrisonic, and Easy Clean (p > 0.05). None of the agitation methods could remove the smear layer altogether.
Conclusions
Ultramint X resulted in the most significant number of completely clean specimens.