1.The application of blink reflex in diabetes mellitns
Chinese Journal of Primary Medicine and Pharmacy 2009;16(4):592-593
Objective To study the characteristics and clinical value of blink reflex in patients with diabetes mellitus. Methods Blink reflex were measured in 40 diabetes melletus and 30 normal adults. Results The result showed that diabetic group R1, R2 and R2' wave latency was significantly longer than the control group,meanwhile their amplitudes were significantly lower than that of control. And to 112 and R2' extended significantly,which showed that the damage to the central nervous system in diabetes can affect the brain stem. With the extension of duration of diabetes BR abnormal rate gradually increased. Conclusion It was concluded that BR provide an objective and sen-sitive index for the damage of the central nervous system in diabetes.
2.Microsurgical treatment of anterior communicating aneurysms under combined neuroelectrophysiologi-cal monitoring
Jialiang LI ; Yan LI ; Wenxiang LIU ; Qi HUANG ; Pengfei MIAO ; Xiang LI ; Renshan NIU ; Yin LIU
Clinical Medicine of China 2014;(6):564-566
Objective To investigate the curative effect of microsurgical treatment of anterior communicating aneurysm via the moeifiee pterional approach uneer combinee neuroelectrophysiological monitoring. Methods The clinical eata of 35 cases of anterior communicating aneurysms were analyzee retrospectively. All the cases were treatee by the microsurgical treatment via moeifiee pterional approach uneer combinee neuroelectrophysiological monitoring. Results All the anterior communicating aneurysms were clippee completely by microsurgical treatment uneer combinee neuroelectrophysiological monitoring. The curative effect was assessee at eischarge accoreing to GOS,inclueing gooe in 29 cases(82. 9% ,29 / 35),moeerate eisability in 4 cases(11. 4% ,4 / 35),severe eisability in 1 case(2. 9% ,1 / 35),eiee in 1 case(2. 9% ,1 / 35). Conclusion Microsurgical treatment of anterior communicating aneurysms via moeifiee pterional approach uneer combinee neuroelectrophysiological monitoring is a safe ane effective methoe,which might be helpful to reeuce the ratio of postoperative eisability ane mortality,ane then improve quality of life for patients.
3.A New Quartz Crystal Microbalance Measuring Method with Expansive Frequency Range and Broadband Adaptive Response Capacity
Junpeng ZHOU ; Yu BAO ; Qing LIN ; Renshan PANG ; Lianming WANG ; Li NIU
Chinese Journal of Analytical Chemistry 2014;(5):773-778
In order to solve the problems of present quartz crystal microbalance ( QCM ) measuring instruments, such as high demand for crystal cutting technology and uncomprehensive measurements for crystal parameters, a modified quadrature demodulation-based method was proposed with broadband adaptive response capacity and high frequency resolution. Moreover, it is also capable of measuring both resonant frequencies and dissipation factor D synchronously and continuously. Experimental results at room temperature indicated that the adaptive frequency range was 1-9 MHz while the frequency resolution was less than 1 Hz, measured resonance frequency shifts of crystals in the range scale linearly with the equal thickness increments of poly acrylic acid ( PAA) membrane on the working electrode, and with the volatilization of different solvent factor D is measured continuously and effectively along the time axis. To sum up, compared with traditional ones, this new method has lower material cost and more obtained parameters.