1.A study of the iso-center point coincidence between accelerator and radiotherapy planning system
Xiaoyang SUN ; Bo YANG ; Haowen PANG ; Guangpeng ZHANG ; Jing ZHANG ; Renjin CHEN ; Jingbo WU
Chinese Journal of Radiation Oncology 2016;25(6):625-627
Objective To study the iso-center point coincidence of two accelerators with treatment planning system (TPS) based on γ passing rates of intensity-modulated radiotherapy (IMRT) plan verification.Methods Twenty-one IMRT plans were verified by Varian accelerator and twenty by Elekta accelerator with a gamma criterion of 3 mm/3%.The passing rates were measured when the iso-center point of TPS had-2,-1,0,1,and 2 mm shift in the x or y direction.A binomial curve of γwas fit to figure out the values of the two accelerators on the x and y axes when γ value reached the maximum.The γ pass rate difference was analysed by x2 test.Results The mean values of γ-2,γ-1,γ0,γ1,and γ2 in the x direction were (92.56±3.27) %,(96.53± 1.82) %,(96.13± 1.41) %,(90.14± 2.87) %,and (82.28± 4.69) % for Varian accelerator,and (94.82± 2.04) %,(97.05± 2.02) %,(98.38± 1.33) %,(97.96± 1.44) %,and (94.49±2.34)% for Elekta accelerator.There was no significant difference in the mean value of γ0between the two accelerators (P=0.332).When γvalue reached the maximum,the values on the x and y axes were0.65 and-0.30 mm for Varian accelerator and 0.01 and 0.30 mm for Elekta accelerator,respectively.Conclusions In the same TPS,different accelerators have different degrees of coincidence of the actual field center point with the iso-center point of TPS,to which more attention should be paid in clinical practice.
2.Effect of needle arrangement on the lung dose in interstitial brachytherapy for lung cancer
Bo YANG ; Xiaoyang SUN ; Haowen PANG ; Xiangxiang SHI ; Guangpeng ZHANG ; Longjing TAN ; Renjin CHEN ; Tao TANG ; Hong WU ; Jingbo WU
Chinese Journal of Radiation Oncology 2017;26(12):1417-1420
Objective To analyze the effect of needle arrangement on the lung dose in interstitial brachytherapy for lung cancer. Methods For 15 patients undergoing interstitial brachytherapy for lung cancer, a virtual radiotherapy plan in which needle arrangement was not restricted by the ribs was designed and compared with the original plan. For the two plans, V5, V20, V30, and mean lung dose(MLD)of the whole lung were determined when the prescribed doses were 10,30, 60, and 120 Gy, respectively. The data were analyzed by Wilcoxon signed-rank test. Results The lung V5,V20, V30, and MLD were significantly smaller in the virtual plan than in the actual plan(all P<0.05). Conclusions Irregular needle arrangement prevents a further reduction in the lung dose in interstitial brachytherapy for lung cancer. In the implantation surgery, therefore, the needles should be arranged as regularly as possible.