1.Discussion on the determination of bicarbonate in hemodialysis.
Zhong LU ; Minju HUANG ; Zhixia CHEN
Chinese Journal of Medical Instrumentation 2010;34(5):368-369
During the routine tests, it's found that the testing method related to Hemodialysis mentioned in the industry standard YY0598-2006 cannot reflect the real bicarbonate concentration in Hemodialysis. To discuss the reaction principle and its interference factors deeply by studying the assay determination of bicarbonate in Hemodialysis, and it could be cited as reference for amending the quality standard or troubleshooting. The improved way of determining bicarbonate concentration in Hemodialysis is also put up.
Bicarbonates
;
analysis
;
Dialysis Solutions
;
analysis
;
standards
;
Renal Dialysis
;
methods
;
standards
2.Introduce the quality control of equipment of hemodialysis center.
Chinese Journal of Medical Instrumentation 2010;34(4):289-290
This paper introduces the quality control of equipment of hemodialysis center, which includes the wate of hemodialysis, disinfection of the equipment, maintenance, check and calibration of the equipment.
Durable Medical Equipment
;
standards
;
Quality Control
;
Renal Dialysis
;
instrumentation
3.Current status and standards for establishment of hemodialysis units in Korea.
Young Ki LEE ; Kiwon KIM ; Dae Joong KIM
The Korean Journal of Internal Medicine 2013;28(3):274-284
The number of hemodialysis patients and dialysis facilities is increasing each year, but there are no surveillance programs validating that the services and equipment of each hemodialysis unit meet specified safety and quality standards. There is a concern that excessive competition and illegal activities committed by some dialysis facilities may violate patients' right to health. Contrastingly, developed countries often have their own survey program to provide initial certification and monitoring to ensure that these clinics continue to meet basic requirements. Because hemodialysis units provide renal replacement therapy to critical patients suffering from severe chronic renal failure, appropriate legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Therefore, several standards providing minimum requirements for the area of hemodialysis unit, equipment for emergency care, physician and nurse staffs, water purification and quality management are urgently needed.
Ambulatory Care Facilities/*standards
;
Health Manpower
;
Humans
;
Renal Dialysis/*standards
;
Republic of Korea
4.Maintenance and complications of hemodialysis equipment.
Chinese Journal of Medical Instrumentation 2009;33(2):150-151
Through the hemodialysis machine and water treatment systems maintenance, the result of complications caused by dialysis can be eliminated. It also of extended the life of hemodialysis machines and improve the quality of dialysis.
Equipment Failure
;
Equipment and Supplies
;
standards
;
Humans
;
Maintenance
;
Renal Dialysis
;
adverse effects
;
instrumentation
;
Water Supply
;
standards
5.Discussion on the building of post market risk analysis method in hemodialysis device.
Honglei XU ; Xiaolong PENG ; Xiaojun TIAN ; Peilian WANG
Chinese Journal of Medical Instrumentation 2014;38(5):371-374
This paper discussed the building of post market risk analysis method in hemodialysis device from the point of government supervision. By proposing practical research methods for post market risk identification and estimation on hemodialysis device, providing technical guidance for government to put risk management of hemodialysis device into effect, and offering reference for enterprises to carry out post market risk evaluation on their products as well.
Government Regulation
;
Renal Dialysis
;
instrumentation
;
standards
;
Research Design
;
Risk Assessment
;
Risk Management
6.Effect of long intermittent hemodialysis on improving dialysis adequacy of maintenance hemodialysis patients.
Wen-di DAI ; Dong-Liang ZHANG ; Wen-Ying CUI ; Wen-Hu LIU
Chinese Medical Journal 2013;126(24):4655-4659
BACKGROUNDWith the increase in hemodialysis (HD) patients, the blood dialysis patient's quality of life (QoL) and long-term survival are still a challenge for clinicians. Recent studies have found that most of the HD patients have sleep disorders, which have a certain correlation with long-term survival and QoL. But there are few studies of Chinese in this field. This study aimed to investigate whether increasing the dialysis dose can improve sleep quality, so we treated HD patients on long intermittent hemodialysis (LIHD).
METHODSForty patients who were treated by conventional HD at the Beijing Friendship Hospital Blood Purification Center were offered the option of LIHD. The patients' laboratory data, medication use, and questionnaire answers were analyzed. Conventional HD was delivered thrice weekly with 4 hours per treatment, and LIHD was delivered thrice weekly with 8 hours per treatment. The study lasted 6 months. Questionnaires included sleep quality survey and QoL SF-36; the former includes the Athens Insomnia Scale, Pittsburgh Sleep Quality Index (PSQI), and Epworth Sleepiness Scale (ESS).
RESULTSAfter conversion to LIHD the dialysis efficiency (Kt/V) significantly increased than before (P < 0.05) and clearance rate of urea nitrogen also increased from 67 to 78% (P < 0.01). After conversion, median values for Hb increased from 108.95 to 126.55 g/L (P < 0.01); albumin increased from 38.85 to 40.05 g/L (P < 0.01). Phosphorus decreased from 2.69 to 1.54 mmol/L (P < 0.01), but there was no alteration in blood calcium; phosphorus and calcium-phosphate product levels were under more control, but parathyroid hormone (iPTH) level did not change after conversion to LIHD. After conversion, blood pressure (BP) was better controlled than before and the mean number of antihypertensive drugs prescribed declined from 2.9 to 0.5 (P < 0.01). There was a significant reduction in the use of erythropoietin-stimulating agent of 5250 U/w (P < 0.01). Sleep quality significantly improved in the 2 months after conversion to LIHD, and the PSQI score decreased from 10.80 to 5.45 and the ESS score decreased from 12.05 to 5.30 (P < 0.01). However, sleep quality started to decline after 2 months on LIHD. QoL SF-36 score increased from 410.92 to 592.53 (P < 0.01).
CONCLUSIONLIHD offers an effective improvement in dialysis adequacy for Chinese maintenance HD patients, but it improves sleep quality only briefly which may be related to loss of serum calcium and parathyroid dysfunction.
Adult ; Calcium ; blood ; Female ; Humans ; Kidney Failure, Chronic ; blood ; therapy ; Male ; Middle Aged ; Phosphorus ; blood ; Quality of Life ; Renal Dialysis ; standards
7.Impact of Health Insurance Type on the Quality of Hemodialysis Services: A Multilevel Analysis.
Jin Hee JUNG ; Soon Man KWON ; Kyoung Hoon KIM ; Seon Kyoung LEE ; Dong Sook KIM
Journal of Preventive Medicine and Public Health 2010;43(3):245-256
OBJECTIVES: This study aims to compare quality indicators for the hemodialysis services between patients with health insurance and those with medical aid. METHODS: This study used data from sampled hospitals that provided a hemodialysis service. A total of 2287 patients were selected, and the information for hemodialysis service has been granted from medical record reviews. A multi-level regression analysis was used to examine the differences in process and outcome indicators for hemodialysis between patients with health insurance and those with medical aid. Process indicators were defined as: frequency of hemodialysis, hemodialysis time, erythropoietin (EPO) use, measurement of hemodialysis dose at least once a month, measurement of phosphate at least once every three months, and measurement of albumin at least once every three months. Outcome indicators were defined as: hemodialysis adequacy, anemia management, blood pressure management, and calcium, phosphate and nutrition management. The total scores for outcome indicators ranged from 0 (worst) to 4 (best). RESULTS: There was a significant difference in the measurement of hemodialysis dose at least once a month between patients with health insurance and those with medical aid (OR 0.66, 95% CI=0.43-0.99). However, frequency of hemodialysis, hemodialysis time, EPO use, measurement of phosphate at least once every three months, measurement of albumin at least once every three months, hemodialysis adequacy management, Hb> or =11 g/dL, blood pressure within the range of 100-140/60-90 mmHg, calcium x phosphate< or =55 g2/dL2 and albumin> or =4 g/dL were not significantly different between the groups. CONCLUSIONS: There were no significant differences in outcome indicators for hemodialysis between the groups. Further studies are warranted into the mechanism that results in no differences in the outcome indicators for hemodialysis.
Aged
;
Female
;
Humans
;
Insurance, Health/*classification
;
Male
;
Medical Audit
;
Middle Aged
;
*Quality Indicators, Health Care
;
*Quality of Health Care
;
Renal Dialysis/*standards
;
Republic of Korea
8.Spurious Elevation of Glucose Concentration during Administration of High Dose of Ascorbic Acid in a Patient with Type 2 Diabetes on Hemodialysis.
Soo Kyoung KIM ; Jong Ryeal HAHM ; Ho Su KIM ; Sungsu KIM ; Tae Sik JUNG ; Jung Hwa JUNG ; Hye Ryun LEE ; Deok Ryong KIM
Yonsei Medical Journal 2013;54(5):1289-1292
We describe herein a case of life-threatening hypoglycemia due to spurious elevation of glucose concentration during the administration of ascorbic acid in a type 2 diabetic patient. A 31-year-old female was admitted for proliferative diabetic retinopathy treatment and prescribed high dose ascorbic acid. During hospitalization, she suddenly lost her consciousness and her glucose concentration was 291 mg/dL, measured using self-monitoring blood glucose (SMBG) device, while venous blood glucose concentration was 12 mg/dL. After intravenous injection of 50% glucose solution, the patient became alert. We reasoned that glucose measurement by SMBG device was interfered by ascorbic acid. Physicians should be aware of this interference; high dose ascorbic acid may cause spurious elevation of glucose concentration when measuring with SMBG devices.
Adult
;
Ascorbic Acid/administration & dosage/adverse effects/contraindications/*therapeutic use
;
Blood Glucose
;
Blood Glucose Self-Monitoring/instrumentation/standards
;
Diabetes Mellitus, Type 2/blood/drug therapy
;
Female
;
Humans
;
Hypoglycemia/*diagnosis
;
Renal Dialysis
9.New Decision Criteria for Selecting Delta Check Methods Based on the Ratio of the Delta Difference to the Width of the Reference Range Can Be Generally Applicable for Each Clinical Chemistry Test Item.
Sang Hyuk PARK ; So Young KIM ; Woochang LEE ; Sail CHUN ; Won Ki MIN
Annals of Laboratory Medicine 2012;32(5):345-354
BACKGROUND: Many laboratories use 4 delta check methods: delta difference, delta percent change, rate difference, and rate percent change. However, guidelines regarding decision criteria for selecting delta check methods have not yet been provided. We present new decision criteria for selecting delta check methods for each clinical chemistry test item. METHODS: We collected 811,920 and 669,750 paired (present and previous) test results for 27 clinical chemistry test items from inpatients and outpatients, respectively. We devised new decision criteria for the selection of delta check methods based on the ratio of the delta difference to the width of the reference range (DD/RR). Delta check methods based on these criteria were compared with those based on the CV% of the absolute delta difference (ADD) as well as those reported in 2 previous studies. RESULTS: The delta check methods suggested by new decision criteria based on the DD/RR ratio corresponded well with those based on the CV% of the ADD except for only 2 items each in inpatients and outpatients. Delta check methods based on the DD/RR ratio also corresponded with those suggested in the 2 previous studies, except for 1 and 7 items in inpatients and outpatients, respectively. CONCLUSIONS: The DD/RR method appears to yield more feasible and intuitive selection criteria and can easily explain changes in the results by reflecting both the biological variation of the test item and the clinical characteristics of patients in each laboratory. We suggest this as a measure to determine delta check methods.
Alanine Transaminase/blood
;
Alkaline Phosphatase/blood
;
Aspartate Aminotransferases/blood
;
Bilirubin/blood
;
Blood Urea Nitrogen
;
Chemoembolization, Therapeutic
;
Clinical Chemistry Tests/methods/*standards
;
Creatine/blood
;
*Decision Trees
;
Humans
;
Reference Values
;
Renal Dialysis
;
Uric Acid/blood
10.New Decision Criteria for Selecting Delta Check Methods Based on the Ratio of the Delta Difference to the Width of the Reference Range Can Be Generally Applicable for Each Clinical Chemistry Test Item.
Sang Hyuk PARK ; So Young KIM ; Woochang LEE ; Sail CHUN ; Won Ki MIN
Annals of Laboratory Medicine 2012;32(5):345-354
BACKGROUND: Many laboratories use 4 delta check methods: delta difference, delta percent change, rate difference, and rate percent change. However, guidelines regarding decision criteria for selecting delta check methods have not yet been provided. We present new decision criteria for selecting delta check methods for each clinical chemistry test item. METHODS: We collected 811,920 and 669,750 paired (present and previous) test results for 27 clinical chemistry test items from inpatients and outpatients, respectively. We devised new decision criteria for the selection of delta check methods based on the ratio of the delta difference to the width of the reference range (DD/RR). Delta check methods based on these criteria were compared with those based on the CV% of the absolute delta difference (ADD) as well as those reported in 2 previous studies. RESULTS: The delta check methods suggested by new decision criteria based on the DD/RR ratio corresponded well with those based on the CV% of the ADD except for only 2 items each in inpatients and outpatients. Delta check methods based on the DD/RR ratio also corresponded with those suggested in the 2 previous studies, except for 1 and 7 items in inpatients and outpatients, respectively. CONCLUSIONS: The DD/RR method appears to yield more feasible and intuitive selection criteria and can easily explain changes in the results by reflecting both the biological variation of the test item and the clinical characteristics of patients in each laboratory. We suggest this as a measure to determine delta check methods.
Alanine Transaminase/blood
;
Alkaline Phosphatase/blood
;
Aspartate Aminotransferases/blood
;
Bilirubin/blood
;
Blood Urea Nitrogen
;
Chemoembolization, Therapeutic
;
Clinical Chemistry Tests/methods/*standards
;
Creatine/blood
;
*Decision Trees
;
Humans
;
Reference Values
;
Renal Dialysis
;