1.Hyperfractionated radiotherapy for re-irradiation of recurrent esophageal cancer
Kazuya TAKEDA ; Haruo MATSUSHITA ; Rei UMEZAWA ; Takaya YAMAMOTO ; Yojiro ISHIKAWA ; Noriyoshi TAKAHASHI ; Yu SUZUKI ; Keiichi JINGU
Radiation Oncology Journal 2021;39(4):265-269
Purpose:
Re-irradiation is a treatment option for recurrent esophageal cancer patients with a history of radiotherapy, but there is a risk of severe late adverse effects. This study focused on the efficacy and safety of re-irradiation using hyperfractionated radiotherapy.
Materials and Methods:
Twenty-six patients who underwent re-irradiation by the hyperfraction technique using twice-daily irradiation of 1.2 Gy per fraction for recurrent esophageal cancer were retrospectively included in this study. The overall survival period after the start of secondary radiotherapy and the occurrence of late adverse effects were investigated.
Results:
Of 26 patients, 21 (81%) received re-irradiation with definitive intention and 21 (81%) underwent concurrent chemotherapy. The median re-irradiation dose was 60 Gy in 50 fractions in 25 treatment days, and the median accumulated irradiation dose in equivalent dose in 2 Gy per fraction was 85.4 Gy with an α/β value of 3. The median interval between two courses of radiotherapy was 21.0 months. The median overall survival period was 15.8 months and the 1-year and 3-year overall survival rates were 64.3% and 28.3%, respectively. Higher dose of re-irradiation and concurrent chemotherapy significantly improved survival (p < 0.001 and p = 0.019, respectively). Severe late adverse effects with the Common Terminology Criteria for Adverse Events grade 3 or higher were observed in 5 (19.2%) patients, and 2 (7.7%) of them developed a grade 5 late adverse effect.
Conclusion
High-dose re-irradiation using a hyperfractionated schedule with concurrent chemotherapy might be related to good prognosis, while the rate of late severe adverse effects is not high compared with the rates in past reports.
2.Bispectral index-guided propofol sedation during endoscopic ultrasonography
Ayana OKAMOTO ; Ken KAMATA ; Takeshi MIYATA ; Tomoe YOSHIKAWA ; Rei ISHIKAWA ; Tomohiro YAMAZAKI ; Atsushi NAKAI ; Shunsuke OMOTO ; Kosuke MINAGA ; Kentaro YAMAO ; Mamoru TAKENAKA ; Yasutaka CHIBA ; Toshiharu SAKURAI ; Naoshi NISHIDA ; Masayuki KITANO ; Masatoshi KUDO
Clinical Endoscopy 2022;55(4):558-563
Background/Aims:
Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS).
Methods:
This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room.
Results:
The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001).
Conclusions
During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.