2.Optimizing Imaging Quality and Radiation Dose by the Age-Dependent Setting of Tube Voltage in Pediatric Chest Digital Radiography.
Hui GUO ; Wen Ya LIU ; Xiao Ye HE ; Xiao Shan ZHOU ; Qun Li ZENG ; Bai Yan LI
Korean Journal of Radiology 2013;14(1):126-131
OBJECTIVE: The quality and radiation dose of different tube voltage sets for chest digital radiography (DR) were compared in a series of pediatric age groups. MATERIALS AND METHODS: Forty-five hundred children aged 0-14 years (yr) were randomly divided into four groups according to the tube voltage protocols for chest DR: lower kilovoltage potential (kVp) (A), intermediate kVp (B), and higher kVp (C) groups, and the fixed high kVp group (controls). The results were analyzed among five different age groups (0-1 yr, 1-3 yr, 3-7 yr, 7-11 yr and 11-14 yr). The dose area product (DAP) and visual grading analysis score (VGAS) were determined and compared by using one-way analysis of variance. RESULTS: The mean DAP of protocol C was significantly lower as compared with protocols A, B and controls (p < 0.05). DAP was higher in protocol A than the controls (p <0.001), but it was not statistically significantly different between B and the controls (p = 0.976). Mean VGAS was lower in the controls than all three protocols (p < 0.001 for all). Mean VGAS did not differ between protocols A and B (p = 0.334), but was lower in protocol C than A (p = 0.008) and B (p = 0.049). CONCLUSION: Protocol C (higher kVp) may help optimize the trade-off between radiation dose and image quality, and it may be acceptable for use in a pediatric age group from these results.
Adolescent
;
Age Factors
;
Analysis of Variance
;
Child
;
Child, Preschool
;
Humans
;
Infant
;
Infant, Newborn
;
Pediatrics/*standards
;
Prospective Studies
;
*Radiation Dosage
;
Radiation Protection/standards
;
Radiographic Image Enhancement/*standards
;
Radiography, Thoracic/*standards
3.Computed tomographic characteristics of acute thoracolumbar intervertebral disc disease in dogs.
Changyun LIM ; Oh Kyeong KWEON ; Min Cheol CHOI ; Jihye CHOI ; Junghee YOON
Journal of Veterinary Science 2010;11(1):73-79
Forty canine patients with a presumptive diagnosis of the intervertebral disc herniation at the thoracolumbar region were imaged. A neurological examination was performed and all patients were classified under four grades by the examination. The degrees of attenuation of the herniated disc material were measured in Housefield units (HU) in each image. The ratio of the area to herniated disc material and the height to disc material were measured. The clinical grade was correlated with the area ratio of the herniated disc material to the spinal cord, but not correlated with the height ratio of that. In the patients with epidural hemorrhage at surgery, HUs of the herniated disc material was lower than those with no epidural hemorrhage at surgery. Non-contrast computed tomography scans of the spine can be useful in diagnosing acute intervertebral disc disease in chondrodystrophoid breeds, evaluating patient status and identifying concurrent epidural hemorrhage.
Animals
;
Dog Diseases/*pathology/radiography
;
Dogs
;
Intervertebral Disk Displacement/radiography/*veterinary
;
Lumbar Vertebrae/*pathology/radiography
;
Retrospective Studies
;
Thoracic Vertebrae/*pathology/radiography
;
Tomography, X-Ray Computed/methods/standards/*veterinary
4.Reasonable applications of automatic exposure control in computed radiography.
Xian-cheng CUI ; Zhi WANG ; Yong HAO ; Liang YIN ; Jun LUO ; Wen-chao SUN
Chinese Journal of Medical Instrumentation 2005;29(1):57-59
This paper is to explore the reasonable applications of automatic exposure control in computed radiography, and to improve the quality of CR images. It is very important to select a suitable KV value in automatic exposure control in computed radiography. At the same time, a suitable ionization chamber, correct density compensation and necesary post-processing should be selected.
Adolescent
;
Adult
;
Aged
;
Automation
;
Child
;
Child, Preschool
;
Female
;
Head
;
diagnostic imaging
;
Humans
;
Image Processing, Computer-Assisted
;
Infant
;
Lumbar Vertebrae
;
diagnostic imaging
;
Male
;
Middle Aged
;
Quality Control
;
Radiation Dosage
;
Radiographic Image Enhancement
;
methods
;
Radiography, Thoracic
;
Tomography, X-Ray Computed
;
methods
;
standards
5.Ministry of Health Clinical Practice Guidelines: Chronic Obstructive Pulmonary Disease.
Tow Keang LIM ; Cynthia B CHEE ; Patsy CHOW ; Gerald Sw CHUA ; Soo Kiang ENG ; Soon Keng GOH ; Kwee Keng KNG ; Wai Hing LIM ; Tze Pin NG ; Thun How ONG ; S T Angeline SEAH ; Hsien Yung TAN ; K H TEE ; Vimal PALANICHAMY ; Meredith T YEUNG
Singapore medical journal 2018;59(2):76-86
The Ministry of Health (MOH) has updated the Clinical Practice Guidelines on Chronic Obstructive Pulmonary Disease (COPD) to provide doctors and patients in Singapore with evidence-based treatment for COPD. This article reproduces the introduction and executive summary (with recommendations from the guidelines) from the MOH Clinical Practice Guidelines on COPD, for the information of SMJ readers. Chapters and page numbers mentioned in the reproduced extract refer to the full text of the guidelines, which are available from the Ministry of Health website: https://www.moh.gov.sg/content/moh_web/healthprofessionalsportal/doctors/guidelines/cpg_medical.html. The recommendations should be used with reference to the full text of the guidelines. Following this article are multiple choice questions based on the full text of the guidelines.
Adult
;
Aged
;
Evidence-Based Medicine
;
Humans
;
Middle Aged
;
Palliative Care
;
Prevalence
;
Pulmonary Disease, Chronic Obstructive
;
diagnosis
;
therapy
;
Pulmonary Medicine
;
standards
;
Quality Improvement
;
Radiography, Thoracic
;
Risk Factors
;
Singapore
;
Steroids
;
therapeutic use