1.The Evaluation of MRI in Diagnosis of Osteosarcoma
Qianqian HUA ; Xuelin ZHANG ; Qun ZHONG
Journal of Practical Radiology 2000;0(12):-
Objective To evaluate the MRI features of osteosarcoma.Methods 38 cases of osteosarcoma proved pathologically were retrospectively analyzed.All of them were examined by plain MRI scan,25 cases were examined by enhanced scan.Results The diagnostic accuracy of osteosarcoma of MRI was 93.9%.There were 30 cases of the extension into the medullary cavity,18 cases of soft tissue mass,10 cases of the destruction in epiphysis and 4 cases of the invasion in articular cartilage,especially T2 weighted STIR image and enhanced MRI scans were advantageous in showing the images mentioned above and in judging of the change after treated.Conclusion MRI is very important in diagnosis and clinical therapy of osteosarcoma.
2.Biological performance of Ni-Cr porcelain alloy
Qingyi SHEN ; Guoqiang LI ; Qun ZHONG
Chinese Journal of Tissue Engineering Research 2009;13(38):7555-7558
Biological performances of Ni-Cr porcelain alloy are highly correlated with released metallic ions. Released metal ions from Ni-Cr porcelain alloy, particularly Ni, Be can induce inflammation of the adjacent periodontal tissue and oral mucosa. In vitro evidence has indicated that the immune response can be altered by various metal ions. Allergic reactions due to metallic dental restorations have been documented. Ni has especially been identified as being highly allergenic. The cytotoxicity and corrosion level of Ni-Cr porcelain alloy is increased after recasting. The Ni-Cr porcelain alloy produced according to technology requirements has good biological safety. Ni-Cr porcelain alloy released a few of metal ions which might induce allergy and density of adjacent periodontal tissues, for the stimulation effect of these metal ions. There is no evidence to suggest that Ni-Cr porcelain alloy restorations has systemic toxicity or carcinogenic/genotoxic effect to human.
4.Sixty cases of facial paralysis on acute stage treated with bleeding therapy by plum needles.
Qun GU ; Wei-Zhong YANG ; Ting-Ting CHEN
Chinese Acupuncture & Moxibustion 2012;32(8):701-702
Adolescent
;
Adult
;
Aged
;
Facial Paralysis
;
therapy
;
Female
;
Hemorrhage
;
Humans
;
Male
;
Middle Aged
;
Needles
;
Young Adult
5.Effects of Clara Cell Secretary Protein in Modulating Lung Inflammatory and Immune Responses to Respiratory Syncytial Virus Infection
yue-qun, MI ; yi-xiao, BAO ; ya-zhong, ZHU
Journal of Applied Clinical Pediatrics 1994;0(04):-
Objective To determine a possible role for Clara cell secretary protein(CCSP)during acute RSV infection.Method CCSP-deficient [CCSP (-/-)]and wild-type (WT) mice were intratracheally infected with RSV and the lung inflammatory response to RSV infection were assessed.Results RSV-F gene expression increased in the lungs of CCSP (-/-) mice compared to WT mice following RSV infection, consistent with increased viral persistence. Lung inflammation was significantly worsened in CCSP (-/-) mice compared to WT mice after RSV infection. Th2 cytokines and neutrophil chemokines increased in the lungs of CCSP (-/-) mice following RSV infection.Conclusion These findings suggest that lack of CCSP may promote the inflammatory and Th2 immune response to RSV infection.
6.Three-dimensional finite element analysis of severe wedge-shaped defective premolar restored with fiber post and composite resin
Qingyi SHEN ; Dongmei WANG ; Qun ZHONG ; Dong CHEN
Chinese Journal of Tissue Engineering Research 2014;(30):4777-4782
BACKGROUND:Someone regards that treatments such as root canal therapy and post-core restoration can increase the fracture probability of teeth. Can fiber reinforced composite post enhance the fracture resistance of the severe wedge-shaped defected premolar? Three-dimensional finite element can simplify complex dental systems into a model analyzed by computer, and conduct biomechanical research through the model analysis. OBJECTIVE:To analyze the stress distribution of sever wedge-shaped defected first premolar which restored by fiber reinforced composite post and composite resin. METHODS:We established the three-dimensional finite element models of severe wedge-shaped defected maxil ary first premolar before and after restoration with fiber reinforced composite post and composite resin. The maximum bite force was designed to 267 N that was applied at 45° angle. Then, we analyzed the distribution of maximum principal stress in finite element models. RESULTS AND CONCLUSION:The maximum principal stress was concentrated in the tip of defected region. After restoration, the distribution of maximum principal stress was similar to that of the normal premolar, and the tensile stress was distributed uniformly in the upper-central part of buccal root. It may be beneficial for improving fracture resistance ability of severe wedge-shaped-defect premolar by restoration with fiber reinforced composite post and composite resin.
7.Effects of different post-core materials with different angles on fracture resistant ability of the maxillary central incisor
Yumei QIAN ; Qun ZHONG ; Shuang CHEN ; Sijiu TIE
Chinese Journal of Tissue Engineering Research 2017;21(22):3507-3512
BACKGROUND:In clinical practice,there are some patients with labial inclined anterior teeth which influence their appearance,but they refuse orthodontic treatment because of many factors such as long-term treatment.Alternatively,these patients can receive aesthetics restoration with re-directional post-core and crown.OBJECTIVE:To investigate the influence of three kinds of post-core materials on fracture resistant ability of labial inclined maxillary central incisor with different changed angles.METHODS:Seventy-five maxillary central incisors were randomly divided into three groups:group Ⅰ was restored with Co-Cr post-core and porcelain-fused-to-metal (PFM) crown,group Ⅱ was restored with 50% gold alloy post-core and PFM crown,group Ⅲ was restored with everStick fiber post and composite resin core and PFM crowns.Each group then was divided into five subgroups based on angles between the post-core and long axis of the tooth (0°,10°,20°,30°,40°).All specimens were embedded in acrylic resin and fixed in electronic universal testing machine.Force was loaded to each specimen until fracture occurred,and the maximum load values of fracture and the fracture mode were recorded.RESULTS AND CONCLUSION:The fracture resistance of group Ⅲ was superior to groups Ⅰ and Ⅱ (P < 0.05),but there was no significant difference between group Ⅰ and group Ⅱ (P > 0.05).The maximum load value of the three groups decreased as the changed angle increased.The fracture of group Ⅲ mostly appeared on the 1/3 of the root neck,while the fracture of groups Ⅰ and Ⅱ mostly appeared on the 1/3 of root central or the 1/3 of the root neck.So,the fracture resistance and fracture mode of central incisor under changed angles restored with everStick fiber post were superior to that with cast metal post-core.During re-directional restoration of labial inclined maxillary anterior teeth,everStick fiber post is recommended as a better choice to reduce the risk of catastrophic fractures.Also it suggests that excessive changed angle should be avoided to prevent root fracture.
8.Consecutive Three-dimensional Time-of-Flight MRA:Its Capacity in Determining Cerebral Arteries
Yuzhong ZHANG ; Xuelin ZHANG ; Qun ZHONG ; Renmin CHANG
Journal of Practical Radiology 1996;0(04):-
Objective To evaluate the capacity of consecutive three-dimensional time of flight(3D-TOF)MRA and velocity-encoding(Venc)three-dimensional phase-contrast MRA(3D-PC MRA)in determining cerebral arteries.Methods 15 persons being normal on MR images,consecutive 3D-TOF and 3D-PC MR angiograms were selected prospectively to evaluate the difference between two MRA techniques in determining cerebral arteries.The 38 normal sides of 43 cerebral arteriographic cases undergone MRA and DSA were selected retrospectively to evaluate the capacity of MRA technique in determining cerebral arteries with DSA criterion.Results The branch grades of ACA,MCA or PCA demonstrated by 3D-TOF technique were not respectively different from that by 3D-PC.But the former imaging quality was much better than that of the later.The branch grades of ACA,MCA or PCA shown by MRA were respectively different from those by DSA.These grades of ACA,MCA shown by MRA were one less than those by DSA,and that of PCA shown by MRA was a few different from that by DSA.Conclusion The capacity of consecutive 3D-TOF MRA in demonstrating cerebral arteries is less than that of DSA,but it is enough to most cerebral vascular diseases.
9.Quality standard study on Pteris multifida.
Jian-qun LIU ; Jian LIU ; Wei JIANG ; Guo-yue ZHONG
China Journal of Chinese Materia Medica 2015;40(10):1855-1859
The quality control method and standard were established to control the quality of Pteris multifida in this paper. The tests of water content, total ash, acid-unsoluble ash and ethanol-soluble extractives of P. multifida were carried out according to the methods recorded in appendix of Chinese Pharmacopeia (2010 edition, volume 1) . The TLC method was established by using rhoifolin as references, and a mixture of CHCl3 -MeOH-HAc (6: 1: 1) as the developing solvent system on GF254 thin layer plate. The contents of rhoifolin was determined by HPLC on a Diamonsil C18 (4.6 mm x 250 mm, 5 μm) column, using acetonitrile-water (containing 0.15% formic acid) (16: 84) as mobile phase at a flow rate of 1.0 mL x min(-1). The column temperature was 30 degrees C and the detection wave-length was 350 nm. As a result, pterosin C 3-O-β-D-glucosidede and the other constituents were well separated on TLC detected under the UV light at 254 nm . The methodology validation for the assay of rhoifolin presented that it was in good linear correlation in the ranges of 0.025 5-5.1 μg with the regression equations of Y = 1 092.4X + 9.503 5 (r = 0.999 8), and the average recoveries were 100.3% (RSD 1.3%). The content range of rhoifolin from 16 different batches of Pteris multifida was 0.08-5.06 mg x g(-1). The water content, total ash, acid-unsoluble ash and ethanol-soluble extractives of 16 samples varied in the ranges of 7.35% - 12.96%, 6.90% - 16.33%, 2.07% -11.38% and 13.29% -23.87%, respectively. The suggesting limes in the quality standard for water content, total ash, acid-unsoluble ash, ethanol-soluble extractives and rhoifolin content were ≤ 12% , ≤ 15% , ≤ 8.5% , ≥ 14% and ≥ 0.040%, respectively. The result proved that the established quality of control method was specific and accurate, which can be used for the quality control of P. multifida.
China
;
Chromatography, High Pressure Liquid
;
Chromatography, Thin Layer
;
Drugs, Chinese Herbal
;
chemistry
;
isolation & purification
;
standards
;
Pteris
;
chemistry
;
Quality Control