1.Ultrasound-guided percutaneous ablation treatment for current hepatoblastoma: initial single-center experience
Pengliang LI ; Jia LUO ; Xiaoer ZHANG ; Baoxian LIU ; Luyao ZHOU ; Guangliang HUANG ; Quanyuan SHAN ; Xiaoyan XIE
Journal of Chinese Physician 2017;19(6):813-816
Objective To summarize the first experience with ultrasound-guided percutaneous ab lation treatment (PAT) for recurrent hepatoblastoma (HB) after liver resection in children.Methods From August 2013 to April 2015,PAT was used to treat 6 children with a total of 9 recurrent HB,including 5 patients with 8 tumors in the liver and 1 patient with 1 tumor in the lung.The mean size of ablated tumors was (1.5 ± 0.8) cm,and the tumor size range was 0.7 cm to 3.1 cm.Results Four patients were performed percutaneous radiofrequency ablation (RFA) for recurrent HB;and 2 patients were performed percutaneous ethanol injection (PEI).Ablation success was achieved in all patients (6/6,100%).The complete ablation rate after the first ablation session was 88.9% (8/9) on a tumor-by-tumor basis.Only 1 patient developed a fever with temperature > 39 ℃;it was resolved by conservative therapy.During the follow-up period of 5-30 months,3 patients died to tumor progression.The 1-and 2-year overall survival rates after ablation were 83.3% and 41.7%,respectively.Conclusions PAT is a safe and promising therapy for children with recurrent HB after liver resection,and further investigation in large-scale randomized clinical trials is required to determine its role in the treatment of this disease.
2.Application of contrast-enhanced ultrasonography in pediatric abdominal disease
Quanyuan SHAN ; Xiaoyan XIE ; Huadong CHEN ; Hong JIANG ; Xiaohua XIE ; Luyao ZHOU
Chinese Journal of Ultrasonography 2018;27(1):36-42
Objective To investigate the security,applicability and diagnostic capacity of intravenous contrast-enhanced ultrasound (CEUS) in a pediatric population. Methods A total of 53 pediatric patients (8 months to 18 years old) received 66 intravenous applications of ultrasound contrast agent SonoVue.Side effects were documented.Histology,reference imaging or clinical diagnosis were compared with CEUS diagnostic results. Results Adverse effects occurred in 1/66 applications (1.5% ). For 44 focal liver lesions,the sensitivity was 100%,the specificity was 95.65%,the positive predictive value was 95.45% and the negative predictive value was 100%.The diagnostic accuracy was 97.73%.All 22 other lesions were diagnosed correctly.Conclusions It is safe and feasible to use intravenous CEUS in children.CEUS is worthy of promotion in pediatric patients with abdominal diseases.