1.Expression and clinical value of Pokemon in hepatocellular carcinoma
Quanle ZHANG ; Xizhi XING ; Fengyan LI ; Yanhong QIN ; Liying ZHANG
Journal of International Oncology 2015;42(12):903-906
Objective To detect the serum expression level of Pokemon and explore its clinical value combines with AFP,AFP-L3 or DCP in hepatocellular carcinoma (HCC).Methods In this study,the serum levels of Pokemon,AFP,AFP-L3 and DCP in 30 patients with HCC,34 patients with benign liver diseases and 30 healthy controls were examined by enzyme-linked immunosorbent assay.Then,the clinical significance of Pokemon expression level was analyzed.In the end,the diagnostic evaluation of four serum biomarker alone detection was used to analyze the sensitivity,specificity,the area under the curve and Youden index in the diagnosis of HCC.Results The serum expression level of Pokemon in patients with HCC was (22.63 ± 6.82) ng/ml,which was significantly higher than that in the group with benign liver diseases and healthy controls [(3.54±1.26)ng/ml,t =8.594,P<0.001;(1.95 ±0.57)ng/ml,t =10.021,P<0.001].The expression level of Pokemon in HCC patients was correlated to tumor size (t =2.678,P =0.021) and TNM stag (t =2.578,P =0.034).The serum expression levels of AFP,AFP-L3 and DCP in patients with HCC were (774.56 ± 96.52) ng/ml,(26.37 ± 2.54) ng/ml and (93.49 ± 30.45) mAU/ml,which were significantly higher than those in the group with benign liver diseases [(22.21 ± 3.57) ng/ml,(7.05 ± 2.71) ng/ml,(34.68 ± 10.13) mAU/ml] and healthy controls [(14.65 ± 4.45) ng/ml,(3.84 ± 1.09) ng/ml,(25.87 ± 9.01)mAU/ml,F=58.46,P=0.000;F=12.47,P=0.000;F=23.41,P=0.000].The sensitivity and specificity of Pokemon,AFP,AFP-L3,DCP in the diagnosis of HCC were 84.6% and 87.5%,52.5% and 78.9%,95.0% and 80.0%,77.1% and 87.5%,respectively.Conclusion The enhanced Pokemon serum level,with its sensitivity and specificity higher than AFP,points out Pokemon may be a potentially useful biomarker to diagnose HCC.
2.Application of blood pressure measurement in patients with atrial fibrillation using upper- arm electronic sphygmomanometer
Jing YU ; Ruiying MAO ; Yingying LIU ; Shouling WU ; Xiaokun LIU ; Qi ZHANG ; Quanle HAN
Chinese Journal of Practical Nursing 2016;32(5):343-347
Objective To investigate the feasibility of the upper- arm electronic sphygmomanometer for evaluating the blood pressure in patients with atrial fibrillation. Methods Consecutive hospitalized patients with atrial fibrillation for coronary angiography were selected, and the application of upper- arm electronic sphygmomanometer and mercury sphygmomanometer of blood pressure were applied and in the process of coronary angiography, the radial artery invasive blood pressure was recorded and the correlation was analyzed. Results Mercury sphygmomanometer and radial artery invasive blood pressure measurement had a good consistency on systolic blood pressure, diastolic blood pressure, pulse pressure, mean arterial pressure in atrial fibrillation patients, the differences were not statistically significant (P>0.05). Upper- arm electronic sphygmomanometer and radial artery invasive blood pressure measurement had some consistency (pulse rate range, pulse rate of 70-90 beats / min) on systolic blood pressure, diastolic blood pressure, pulse pressure, mean arterial pressure in atrial fibrillation patients, the differences were not statistically significant (P>0.05). Upper-arm electronic sphygmomanometer and mercury sphygmomanometer had some consistency (pulse rate range, pulse rate of 70-90 beats / min) on systolic blood pressure, diastolic blood pressure, pulse pressure, mean arterial pressure in atrial fibrillation patients, the differences were not statistically significant (P>0.05). The correlation between mercury sphygmomanometer and radial artery invasive blood pressure measurement were found on systolic blood pressure, diastolic blood pressure, pulse pressure, mean arterial pressure in atrial fibrillation patients (r=0.71-0.78, P<0.05),which were better than those of upper- arm electronic sphygmomanometer and radial artery invasive blood pressure measurement (r=0.53-0.70, P <0.05). Conclusions The upper- arm electronic sphygmomanometer can be used for the assessment of blood pressure in patients with atrial fibrillation.
3.Risk Factors Analysis for Prevalence of Acute Myocardial Infarction in Young and Middle-aged Population
Quanle HAN ; Ruiying MAO ; Jing YU ; Shouling WU ; Jingsheng GAO ; Qi ZHANG ; Meiling WU ; Qinghua ZHANG ; Xiaoming LIU ; Xiaoming SHANG ; Xiaokun LIU
Chinese Circulation Journal 2016;31(7):632-635
Objective: To study the risk factors for prevalence of acute myocardial infarction (AMI) in young and middle-aged population. Methods: A prospective cohort study was conducted in 110100 subjects at the age of (18-98) years who received physical examination in Kailuan Group from 2012-06 to 2014-10. Based on the limitations of male≤53 years and female≤63 years, a total of 62367 subjects were enrolled in our study. The subjects were followed-up for 2 years by the end point event of AMI to analyze the risk factors ofAMI occurrence. Results: According to AMI occurrence at the follow-up period, the subjects were divided into 2 groups: AMI group, n=56 and Control group, n=62152. Compared with Control group, AMI group had increased BMI, SBP, DBP and elevated blood levels of LDL-C, TG; AMI group also showed the higher ratios of subjects with the history of diabetes and taking anti-hypertension medication. Cox proportional hazard regression analysis indicated that age (RR=1.37), male (RR=60.54), LDL-C (RR=1.12), and TG (RR=5.93) were the risk factors forAMI occurrence in young and middle-aged population, allP<0.05. Conclusion: Age, male gender, blood levels of LDL-C, and TG were the risk factors for AMI occurrence in young and middle-aged population.
4.Clinical comparative analysis of domestic 16-row and imported 8-row mobile CT head scans
Zhiqiang ZHANG ; Quanle ZHENG ; Haifeng WANG ; Lei YANG ; Fei LI ; Boyun DING ; Li ZHANG ; Shunyi ZHOU ; Yaxin JING ; Zhenfang WANG ; Fei GAO ; Qiusheng DAI ; Ruxiang XU
Chinese Journal of Neuromedicine 2020;19(4):376-380
Objective:To compare the efficacy and safety of domestic 16-row and imported 8-row mobile CT in clinics.Methods:A total of 1469 patients accepted domestic 16-row mobile CT head scans (1604 times) from March 2017 to August 2018 in Bayi Brain Hospital Affiliated to 7 th Medical Center of General Hospital of People's Liberation Army and Langfang Aidebao Hospital; and 15510 patients accepted imported 8-row mobile CT head scans (24994 times) from January 2016 to August 2018 in Bayi Brain Hospital Affiliated to 7 th Medical Center of General Hospital of People's Liberation Army. All patients underwent horizontal plain and enhanced head scans, cerebral CT angiography (CTA), and helical 3D imaging; and the imaging quality, operating power consumption, computed tomography dose index volume (CTDIvol) and stability within scanning volume ranges under different scanning modes of the two CT scans were compared. Results:(1) Imaging quality: the horizontal scanning of domestic 16-row mobile CT could clearly display low-density tissues such as the eyeball, optic nerve, brain stem, sulcus and cerebral gyrus; the imaging quality of both CT scans in patients with traumatic subdural hematoma and ischemic stroke completely met the clinical diagnosis and treatment standards. (2) Operating power consumption: the per-hour operating power consumption of domestic 16-row mobile CT ([0.286±0.018] kW·h) was obviously lower than that of imported 8-row mobile CT ([0.485±0.028] kW·h). (3) Radiological hazard: the CTDIvol of the horizontal scanning volume range in domestic 16-row mobile CT ([36.270±0.281] mGy) was significantly lower than that in the imported 8-row mobile CT ([82.520±0.441] mGy, P<0.05); the CTDIvol of enhanced axis scan volume range in the domestic 16-row mobile CT ([36.270±0.335] mGy) was significantly lower than that in the imported 8-row mobile CT ([70.728±0.424] mGy, P<0.05); the CTDIvol in the volume of CTA imaging of domestic 16-row mobile CT ([20.600±0.087] mGy) was significantly lower than that in the imported 8-row mobile CT ([29.300±0.335] mGy, P<0.05). The domestic 16-row mobile CT was designed with shock absorbers and guides; domestic 16-row mobile CT had small load, a low center of gravity, and good stability as compared with imported 8-row mobile CT. Conclusion:In terms of head scanning applications, the imaging quality of domestic 16-row mobile CT and imported 8-row mobile CT is in full compliance with clinical diagnostic standards, but the energy consumption and radiation risk of domestic 16-row mobile CT is significantly lower than imported 8-row mobile CT, enjoying good stability as compared with imported 8-row mobile CT.