2.Clinical study on relationship between protein tyrosine kinase JAK2 V617F mutation and high altitude polycythemia.
Lin-hua JI ; Zhan-quan LI ; Sen CUI
Chinese Journal of Hematology 2012;33(4):319-320
Adult
;
Aged
;
Altitude
;
Humans
;
Janus Kinase 2
;
genetics
;
Male
;
Middle Aged
;
Point Mutation
;
Polycythemia
;
genetics
3.The characteristics and clinical application of the ArcCHECK diode array for volumetric-modulated arc therapy verification
Chengqiang LI ; Guangjun LI ; Chuanxian JI ; Jianghong XIAO ; Chang GUO ; Hong QUAN ; Sen BAI
Chinese Journal of Radiation Oncology 2013;(3):253-257
Objective To evaluate the characteristics and clinical suitability of the ArcCHECK diode array for volumetric-modulated arc therapy (VMAT) verification.Methods The intrinsic sensitivity,short and long term reproducibility,dose and dose rate dependence,dose per pulsed dependence,field sizes dependence and directional response of the diodes were measured.The results of the diodes were compared with the measurement results of an ionization chamber and calculated results of treatment planning system.Gamma index was used to analyze the dose difference between the calculation and measurement for random selected 211 verified VMAT plans.Results The ArcCHECK performed well for all tests except directional dependence,which varies from a minimum of-3.9% (seen only when the beam was incident on the diode at 180°) to a maximum of 7.7% (approximately at 255°).Average gamma analysis passing rates with 3 mm/3% for 113 nasopharyngeal cancer,48 cervical cancer and 50 rectal cancer patients VMAT plans were 93.5%,95.7% and 97.5%,respectively,statistical significance has been found between either two of the groups (t=-12.69-4.88,all P< 0.01).Conclusions With proposed calibration method,the ArcCHECK diode array is very suitable for VMAT pretreatment verification,the complexity of VMAT plan is the main factor affecting the passing rate.
4.Effect of respiratory movement on cone beam computed tomography images.
Chang GUO ; Renming ZHONG ; Guangjun LI ; Chuanxian JI ; Chengqiang LI ; Hong QUAN ; Sen BAI
Journal of Biomedical Engineering 2014;31(2):314-318
To investigate the impact of respiratory movement to determine the target volume on cone beam CT (CBCT) for lung tumor, we used CIRS dynamic thorax phantom (Model-CIRS008) to simulate the sinusoidal motion of lung tumor. With a constant amplitude, the ratio of the time of near-end-expiratory and near-end-inspiratory (E/I) changed when it was scanned with CBCT. We analyzed the contrast changes of target by extracting the CT value of each pixel on the center line of the target movement direction. The targets were contoured with region growing method and compared with the motion volume generated by the tumor trajectory method. The result showed that the contrast of near-end-expiratory increased and the contrast of near-end-inspiratory decreased with increasing E/I. The contoured volume generated by region growing method decreased with increasing E/I. When E/I = 4, the amplitude A = 1 cm, diameter of 1 cm and 3 cm target volumes were reduced by 48.2% and 22.7%. The study showed that CBCT was not suitable to be used to accurately determine the range of lung tumor movement. The internal target volume (ITV) may be underestimated in CBCT images.
Cone-Beam Computed Tomography
;
Humans
;
Lung Neoplasms
;
diagnostic imaging
;
Movement
;
Phantoms, Imaging
;
Respiration
5.Impact of the image quality of conebeam CT on the accelerator for the Bowtie filter
Wei JIANG ; Sen BAI ; Liangqiang ZHOU ; Guangjun LI ; Qiangfeng XU ; Hong QUAN
Chinese Journal of Radiation Oncology 2010;19(6):548-551
Objective To estimate the impact of the image quality of conebeam CT on the accelerator for the Bowtie filter. Methods This study used the system of conebeam CT on the accelerator,and scaned the phantom of Catphan 500 in the multiplicate scanning conditions with and without the Bowtie filter. The scanning conditions were : voltage :120 kV, 100 kV, 80 kV, electricity:25 mA, 40 mA, 64 mA,time of exposure :40 MHz, collimator: M20, L20, scanning angle :358°. We transmitted the scanning data in the treatment planning systems of Philips Pinnacle 8. 0, and estimated the influence of the image quality.Results With and without the Bowtie filter, all of the images had high geometric precision, and the maximum difference of the nominal and actual distance at the horizontal, vertical and arrowy directions in the transection were 0. 50% and 0. 56% ( t = 0. 44, P > 0. 05 ), 0. 44% and 0. 48% ( t = 1.01, P > 0. 05 ),0. 50% and 0. 56% (t = 1.06,P >0. 05 ), respectively. The spatial resolution was 0. 167 cm, immutably.The ununiformity with the Bowtie filter was decreased of 28.0% -76.0% (t=2.53,P<0. 05)、2.8%-50.0% (t= 3.02,P<0.01 ) than those without the Bowtie filter, and the contrast-to-noise ratio was increased of 4.0% -41.6% (t=2.70,P<0.05)、4.0% -50.0% (t=2.14,P<0.05), using the collimators of M20 and L20, respectively. The Bowtie filter could display clearly the edge of scanning phantom, and improve the CT number of the image edge of phantom. And the linearity of CT number was also improved. Couclusions With the Bowtie filter, the image uniformity, the precision and linearity of CT number and the contrast-to-noise ratio were improved obviously, the edge artifacts were decreased, and the geometric precision and the spacial resolution did not change.
6.Clinical study of bone imaging in 117 cases with primary hyperparathyroidism
Rui-sen, ZHU ; Qiong, LUO ; Han-kui, LU ; Li-bo, CHEN ; Quan-yong, LUO
Chinese Journal of Nuclear Medicine 2010;30(1):38-41
Objective To analyze the characteristics of bone scintigraphy in 117 cases with primary hyperparathyroidism (PHPT).Methods Of these 117 cases (50 males and 67 females),there were 116 parathyroid adenomas and 1 parathyroid cancer.Mean age was 61.1(12-86) years old.All had ~(99)Tc~m-methylene diphosphonate (MDP) bone scintigraphy.The bone images could be classified into 4 categories.Category Ⅰ:normal;category Ⅱ:localized abnormal,which could be subcategorized as Ⅱ A with skull and mandible involvement,and Ⅱ B with Ⅱ A characteristics plus metabolic derangement;category Ⅲ:systemic,whole-body incmased tracer uptake;category Ⅳ:systemic plus localized metabolic derangement.Data were analyzed statistically with X~2 and t-test (isolated samples).Results According to the scintigraphic findings,there were 47 cases(40.17%)of category Ⅰ,35 cases(29.91%) category Ⅱ (21/35cases Ⅱ A and 14/35 cases Ⅱ B),30 cases (25.64%) category Ⅲ,and 5 cases (4.27%) category Ⅳ.Combining categories Ⅱ、Ⅲ and Ⅳ together,there were 70 abnormal cases.These patients had history of abnormal bone images such as bone fracture (39 cases,55.71%),calculus (8 cases,11.43%),bone fracture plus calculus(7 cases,10.00%),osteoporosis (51 cases,72.86%) or ostalgia(26 cases,37.14%);however,in the 47 cases of category Ⅰ,only 1 (2.13%),0,0,10(21.28%)and 10 cases (21.28%),respectively,were found.Therefore.these case history characteristics were statistically significant (X~2=11.152,P=0.01).The tumor size,parathyroid hormone (PTH),blood calcium,blood phosphorus in the patients of abnormal PHPT categories Ⅱ to Ⅲ were(14.52±13.72)cm~3,(731.67±618.40)ng/L,(3.05±0.29) mmol/L and (0.71±0.14) mmol/L,respectively.with statistically significant difference compared to category Ⅰ:(0.78±1.33) cm~3,(112.04±62.98)ng/L,(2.56±0.42) mmol/L and (1.03±0.36)mmol/L(t=-5.724,-5.741,-7.274 and -6.451;all P<0.01).Conclusions (1)Bone scintigraphy was normal in 40% of PHPT patients.(2)The bone images of PHPT could be classified into 4 categories and each could reflect the duration and severity of the disease status on bone.(3)The bone imaging characteristic could be useful for differential diagnostic purposes.
7.Study on resource and varieties of Guoshangye.
Xian-You QU ; Shong-Yun QIN ; De-Quan YANG ; Quan-Sen LI ; Fang-Sheng PENG
China Journal of Chinese Materia Medica 2006;31(2):110-114
OBJECTIVETo investigate the varieties, resoures and identification authentication of Guoshangye used in Tuja and Miao's folk.
METHODThrough field investigations and comparing the collected specimens and literatures, the classification and identification of the species were studied.
RESULT AND CONCLUSIONOrigin of Guoshangye plant was from Pholidota yunnanensis, Bulbophyllum andersonii, B. odoratissimum, B. kamgtimgemse, ect. their morphological characters were identified. Due to limited resource of Guoshangye, the development and protection should be paid more attention.
Analgesics ; pharmacology ; Animals ; Antitussive Agents ; pharmacology ; Conservation of Natural Resources ; Drugs, Chinese Herbal ; isolation & purification ; pharmacology ; History, 19th Century ; History, Medieval ; Humans ; Orchidaceae ; anatomy & histology ; chemistry ; classification ; Pharmacognosy ; history ; Plant Roots ; anatomy & histology ; chemistry ; Plants, Medicinal ; anatomy & histology ; chemistry ; classification
8.An application of the approach combining wavelet transform and energy entropy to remove electrocardiography interference in diaphragmatic electromyographic.
Quan ZHOU ; Zhi YANG ; Zhengping FAN ; Xiaodong LI
Journal of Biomedical Engineering 2013;30(1):16-21
Diaphragmatic electromyographic (EMGdi) signal is a weak biological signal, which contains some significant physiological information of our body respiration system and is susceptible to strong electrocardiography (ECG) signal interference. Based on wavelet transform and theory of information entropy, a new wavelet energy entropy threshold algorithm to remove ECG interference is proposed in this paper. On the base of analysis of wavelet coefficients of each scale, the method sees the information of each scale as a single signal source, equalizes it byzones, and then divides the energy entropy into two categories (i. e., high energy entropy and low energy entropy) through the distribution characteristics of energy entropy of each zone to conduct absolute mean value threshold. In addition, the denoised signal is reconstructed by wavelet coefficients processed. The experimental results showed that the method removed the ECG signal in EMGdi effectively and reserved the available characteristics of EMGdi better.
Algorithms
;
Artifacts
;
Diaphragm
;
physiology
;
Electrocardiography
;
methods
;
Electromyography
;
methods
;
Entropy
;
Humans
;
Signal Processing, Computer-Assisted
;
Wavelet Analysis
9.Extraction and characterization of total DNA from Dendrobium.
Rui PENG ; Hong-yuan SONG ; Quan-sen LI ; Yu WANG
China Journal of Chinese Materia Medica 2003;28(12):1129-1131
OBJECTIVETo explore the quality of DNA with three methods of DNA extraction and the influence on RAPD-PCR.
METHODthe electrophoresis of total DNA, UV spectrophotometry and RAPD analysis were carried out on DNA extracted from three different methods.
RESULTThe DNA concentration and yields were different, which greatly influenced the result of RAPD-PCR.
CONCLUSIONThe higher quality DNA from Dendrobium can be obtained with the method of CTAB-free extraction medium before total DNA was isolated.
Cetrimonium Compounds ; DNA, Plant ; isolation & purification ; Dendrobium ; classification ; genetics ; Electrophoresis ; Plants, Medicinal ; classification ; genetics ; Quality Control ; Random Amplified Polymorphic DNA Technique ; Spectrophotometry, Ultraviolet
10.Castleman disease on neck: clinical report and literature review
Abdumijiti Renaguzi ; LI Shi-hao ; HUANG Zi-xian ; QIN Ze-man ; HUANG Zhi-quan
Journal of Prevention and Treatment for Stomatological Diseases 2017;25(2):110-114
Castleman disease is a rare and complicated disease. A case of Castleman disease (CD) in a 40-year-old woman on the neck was reported and literature review was made to understand the occurrence, clinical characteristics, diagnosis and differential diagnosis, treatment, and prognosis of Castleman disease. Because of the rarity of CD, its occurrence in the general population and the typical clinical manifestations are still lacked. There are two types of CD, namely localized CD and multicentric CD, both of them are not easy to be diagnosised. CT scans in preoperative is helpful for the clinical diagnosis, while histopathological examination and lymph node biopsy are beneficial for the early diagnosis. The treatment result is based on the histopathological examination and lymph node biopsy. The prognosis is different with the type of CD. For the localized CD, the prognosis is usually good, while for the multicentric CD is bad. Both of localized CD and multicentric CD have a certain reoccurrence rate.