1.Recent advances in molecular targeted therapy and expression of iodine uptake relative protein in papillary thyroid carcinoma with BRAFV600E mutation
Chinese Journal of Endocrinology and Metabolism 2013;29(7):624-626
Type-B RAF (BRAF) gene is one of the most popular genes of thyroid carcinoma in recent studies,and its mutation has significant relationships with the occurrence,development,treatment,and prognosis of papillary thyroid carcinoma(PTC).The influence of BRAFV600E mutation on the expression of iodine uptake relative proteins in PTC cells and the value of molecular targeted therapy with BRAFV600Einhibitors in the clinical treatment of PTC in the future were summarized in this review.
2.A Preliminary Study on Anti-inflammatory Effects of Rhamnocitrin from Oxytropis falcata Bunge
Qiuli GU ; Conglin HUANG ; Li ZHANG ; Hua JIANG
Chinese Journal of Information on Traditional Chinese Medicine 2014;(12):48-50
Objective To observe the anti-inflammatory effects of rhamnocitrin in Oxytropis falcata Bunge;To provide experimental evidence for searching the anti-inflammatory active component of Oxytropis falcata Bunge. Methods Kunming mice or Wistar rats were randomly divided into model group, naproxen group and rhamnocitrin high-, medium-, low-dose groups, and corresponding medicines were administered by gavage for 7 days. Animal inflammatory models were established respectively by the mice ear swelling induced by dimethylbenzene, the mice abdominal capillary permeability induced by acetic acid, the rat paw edema created by injection of albumen and the rat granuloma induced by cotton pellet wool. The effects of rhamnocitrin on acute and chronic inflammatory animal models were observed. Results Different doses of rhamnocitrin groups could reduce the animal ear swelling, abdominal capillary permeability, paw edema and granuloma. Compared with the model group, there were obvious differences in rhamnocitrin groups (P<0.05). High dose rhamnocitrin group and naproxen group showed relatively strong inhibition effects on swelling, with statistical significance (P<0.05). Conclusion Rhamnocitrin has anti-inflammatory effects and is an important biological component of Oxytropis falcata Bunge.
3.The comparative study of 4D-CTA with DSA in AVM
Jie ZHANG ; Xianwang YE ; Qiuli HUANG ; Fei TENG
Journal of Practical Radiology 2015;(7):1075-1077,1081
Objective To compare the clinical diagnostic value of 320 row four-dimensional CT angiography (4D-CTA)and digital subtraction angiography (DSA)in untreated arteriovenous malformation (AVM)patients.Methods Thirty-six patients with AVM diagnosed by DSA were included in this study.Two independent readers blind to the results of all examinations evaluated the find-ings of DSA and 4D-CTA of each patient.All results were then documented using a standardized scoring sheet.Results The diagno-sis results of 4D-CTA for AVM lesions in all 36 patients were accurately consistent with those of DSA,including the position,size and vascular structure.There were 14 cases with the largest diameter <3 cm,20 cases 3-6 cm,2 cases >6 cm.Lesions involved only the anterior circulation in 13 cases,only the posterior circulation in 13 cases,and both the anterior and posterior circulation in 10 cases.Conclusion 4D CTA has excellent diagnostic accuracy in the detection of AVM lesions,including size,location,feeding ar-teries and draining veins,with similar value as DSA in the clinical diagnose and evaluation of AVM.
4.Application of automatic tube current modulation technology combined with iterative reconstruction for MSCT in lower extremity arterial imaging
Guangpin MAO ; Qiuli HUANG ; Yuning PAN ; Chengyi HUANG ; Yuemin ZHANG ; Xibo HU ; Yanyong RAN
Chinese Journal of Radiological Medicine and Protection 2016;36(3):230-234
@@
5.Coronary computed tomographic angiography at low concentration of contrast media and low tube voltage in obese patients
Yuning PAN ; Aijing LI ; Xiaomin CHEN ; Dawei REN ; Jian WANG ; Zhaoqian CHEN ; Qiuli HUANG
Chinese Journal of Radiological Medicine and Protection 2016;36(1):67-73
Objective To explore the feasibility of coronary computed tomographic angiography (CCTA) for obese patients with lower tube voltage (100 kV) and lower contrast media concentration (270 mgI/ml) using iterative reconstruction.Methods A total of 48 patients with body mass index greater than 30 kg/m2 were included and randomly divided into 2 groups according to random number table method.The images of the control group were obtained using iodine 370 mgI/ml, a tube voltage of 120 kV, and traditional filtered back projection (FBP) image reconstruction.Patients in the test group were injected with isotonic low concentration contrast media (270 mgI/ml), scanned with a lower tube voltage (100 kV), and adaptive iterative noise reduction image reconstruction algorithm (AIDR-3D) was used.Two experienced physicians scored the image quality in a double-blind way.Independent sample t-test was used to compare the effective dose (E), average CT values, signal to noise ratio (SNR), contrast to noise ratio (CNR), the figure of merit (FOM), image quality scores and the total iodine intake.Side effect was also evaluated.Results The subjective scores for control group and test group were not significantly different (P > 0.05).The scores of two physicians were consistency (Kappa =0.88, P < 0.05).The average CT values, SNR and CNR for the two groups were not significantly different (P > 0.05), but the FOM of the test group was significantly higher than that of the control group (t =-9.250,-8.604,-9.158,-5.341, P < 0.05).Effective dose in the test group was (1.61 ± 0.41) mSv, lower than that of the control group (t =8.373, P < 0.01).The total iodine and iodine injection rate in the test group were both lower than in the control group (t =7.628, 8.480, P < 0.01).The incidence of contrast mediarelated discomfort in the test group was lower than control group (x2 =18.70, 6.25, P < 0.05).Conclusions For obese patients, isotonic low concentration of contrast media and low-dose CCTA could be feasible, which substantially reduce the radiation dose and iodine intake without sacrificing image quality.Trial registration Chinese clinical trial registry, ChiCTR-DPD-15007510.
6.Application value of low radiation dose coronary angiography using 320-slice volume CT
Yuning PAN ; Qiuli HUANG ; Dawei REN ; Anle WU ; Xianwang YE ; Jie ZHANG ; Xiaomin CHEN ; Jian WANG
Chinese Journal of Radiological Medicine and Protection 2012;32(4):420-424,435
Objective To evaluate the image quality and radiation dose of prospective electrocardiography-triggered coronary 320-slice volume CT angiography with different kV, and the feasibility of coronary scan with < 1 mSv radiation dose.Methods Eighty consecutive patients were randomly divided into two groups equally.The tube voltage according to paradigm was 100 kV in group A and 120 kV in group B.All raw data in group A was reconstructed by the software AIDR in CT system to create a new group named as A1. Such parameters as the mean intraluminal attenuation (SI),noise (SD),signal-to-noise ratio (SNR),contrast-to-noise ratio (CNR),effective radiation dose(E) and image quality score measured in group A were compared with those in group B.The values such as SI,SD,SNR,CNR,image quality scores were compared between group A and group A1.The significance of group B and group A1 was compared in SI,SD,SNR,CNR,image quality scores as well.Results E in group A was significantly lower than that in group B[ E =(0.67 ± 0.18) mSv in group A vs.E =(3.08 ± 1.04) mSv in group B].The value of E in group A was decreased by 78% compared to group B(t =- 14.30,P<0.05 ).There was no significant difference in mean image quality scores between two groups(4.57 ± 0.57in groupA vs.4.59 ± 0.59 in group B,t=-1.17,P>0.05).The values of SI,SD,SNR,CNR in group A were (570.8 ±131.5)HU,25.1 ±6.9,24.5 ±9.1,19.8 ±6.1.And the values of SI,SD,SNR,CNR in group B were (460.6 ± 14.3) HU,15.1 ±3.6,31.7 ±7.7,29.3 ±6.8.The values of SI and SD in group A were significantly higher than those in group B(t =4.49,8.18,P <0.05). The values of SNR and CNR in group A were lower than those in group B (t =-4.24,-6.19,P<0.05).The valuesofS1,SD,SNR,CNR,image quality scores in group Al were (557.9 ±24.5) HU,21.1 ±6.0,27.7±10.0,23.4±7.8,4.60 ± 0.56.There was no difference in the SI and the image quality scores between group A and group A1 ( t =1.09,- 1.90,P > 0.05).Conclusions 320-slice volume CT with 100 kV tube voltage and prospective ECG-triggered technique can reduce the radiation dose to less than 1 mSv and obtain optimal images in diagnosis of coronary arterial diseases.
7.Feasibility study of low concentration iso_osmolar contrast agent and low tube voltage for rabbit hepatic computed tomography perfusion scanning
Yandong LIAN ; Yiyong ZENG ; Zhaoqian CHEN ; Yuning PAN ; Aijing LI ; Wenting LAN ; Fenfang FU ; Qiuli HUANG
Chinese Journal of Radiological Medicine and Protection 2017;37(8):630-634
Objective To investigate the feasibility of low-c oncentration iso_osmolar contrast agent together with low tube voltage and iterative reconstruction algorithm in rabbit liver computed tonography (CT) perfusion imaging.Methods A total of 15 bealthy New Zealand rabbits were scanned twice of liver CT perfusion scans each with 24 hours interval.The first scan (routine group) was acquired at 100 kV and 100 mAs with ultravist (370 mg/ml),while the second (double low group) was acquired at 80 kV and 100 mAs with iodixanol (270 mg/ml) at 24 hours after the first scan.The obtained images were reconstructed with filtered back projection (FBP) and adaptive iterative dose reduction (AIDR-3D)algorithms in the controlled and experimental groups,respectively.The perfusion parameters including hepatic artery perfusion(HAP),portal vein perfasion(PVP),hepatic perfusion index(HPI),and total liver perfusion(TLP) and image quality as image quality score,average CT value of abdomen aorta,signalto-noise ratio(SNR),carrier-to-noise ratio(CNR),and figure of merit(FOM) were compared used pair ttest or Mann-Whitney U-test between the two groups wherever appropriate.The effective radiation dose and iodine intake were also recorded and compared.Results The image quality and perfusion parameters had no significantly different between the two groups except for FOM.The effective radiation dose and iodine intake were 38.79% and 27.03% lower in the double low group.Conclusions Low concentration iso _osmolar contrast agent (iodixanol,270 mg/ml) together with low tube voltage (80 kV) helps to reduce radiation dose and iodine intake without compromising perfusion parameters and image quality in liver CT perfusion imaging.
8.Endovascular interventional treatment for iliofemoral artery stenosis or occlusion due to arterial atherosclerosis
Anle WU ; Qiuli HUANG ; Kankan SONG ; Xiaomin CHAI ; Jianguo SHI ; Feng YU ; Jieqin JU
Journal of Interventional Radiology 2009;18(11):819-822
Objective To investigate the feasibility and efficacy of iliofemoral endovascular therapy for the treatment of chronic ischemia of lower extremities due to arterial atherosclerosis. Methods During the period of September 2005-January 2009 percutaneous endovascular angioplasty and stent implantation were performed in 15 consecutive patients with CTA-proved chronic occlusive iliofemoral artery disease. The patients included 11 males and 4 females with a mean age of (72.1 ± 5.9) years (ranged from 61 to 82 years). Before the procedure, all patients underwent clinical and imaging assessments, including Fontaine classification, ankle-brachial pressure index (ABI), and lower limb computed tomography angiography (CTA). According to the length, morphology and location of the occlusive segment, different types of stents were employed together with pereutaneous transluminal angioplasty (PTA) to treat the occluded lilac or superficial femoral artery. At the end of the procedure, distal angiogram was performed to assess the success of the procedure and to exclude thromboembolism or dissection complications. After PTA, the residual stenosis < 30% and/or pressure gradient < 10 mmHg were defined as technical success. Clinical success was identified when patient's clinical symptoms were improved by one or more grade according to Fontaine classification. Results Technical success was totally achieved in all patients with no occurrence of complication. Recanalization of the occluded artery was performed preferably by retrograde ipsilateral femoral artery approach in 5 patients and by contralateral access using the crossover aorta technique in 10 patients. PTA was performed in all patients after stent release to open the occluded vessel to its normal diameter. The mean length of the lilac arterial segment covered with 8 stents was (7.6 ± 1.4) cm (ranged from 6 cm to 10 cm). The mean diameter ± SD of the iliac stents was 9.5 mm ± 1.4 mm (ranged from 8 mm to 12 mm). The mean length of 5 superficial artery implanted stents was (4.5 ± 1.1) cm (ranged from 4 cm to 6 cm). The mean ABI before treatment and six months after treatment was 0.64 (range 0.41 to 0.89) and 0.76 (range 0.50 to 0.95), respectively. The difference in ABI between pre-interventional and post-interventional procedure was statistically significant (t = -4.64, P < 0.01). Clinical improvements according to Fontaine classification were obtained in all patients, in whom technical success was achieved (100%). Conclusion Endovascular interventional procedure is a safe and effective treatment for iliofemoral arterial occlusive disease due to arterial atherosclerosis. PTA combined with subsequent stent implantation can well improve the patient's quality of life as well as the hemodynamics of lower extremities, which is very important for preserving the diseased limb for a long period of time.
9.Hemodynamics assessment by perfusion computed tomography in a canine model of portal hypertension
Yuanwei LIN ; Weijian CHEN ; Qiuli HUANG ; Yunjun YANG ; Pan LIANG ; Boyang YANG ; Hongqing WANG ; Dexin LIN ; Qiyu ZHANG ; Bing XIONG
Chinese Journal of General Surgery 2011;26(5):402-405
Objective To evaluate perfusion computed tomography in the assessment of portal vein pressure changes in an experimental dog model of liver cirrhosis and portal hypertension.Methods The canine model of cirrhosis and portal hypertension was induced by portal vein stenosis with combination of systemic thioacetamide(TAA) feeding in drinking water.All of the Beagles in control group and cirrhotic group underwent hepatic perfusion on a spiral CT scanner.The parameters of hepatic perfusion were calculated by the method of deconvolution.The portal vein pressure was measured by a laparotomy surgery.Results ① In control group, the portal vein pressure was ( 14.5 ± 2.2) cm H2O, while it was (23.1 ± 2.8) cm H2O in PHT group, there was significant difference in the portal vein pressure between the two groups (P<0.05).② The blood flow(BF) was (112 ±14) ml·100 g-1·min-1 in controls, while ( 96 ± 11) ml·100 g-1·min-1 in PHT group; the blood volume ( BV ) in control group and PHT group was (10 ±3) ml·100 g-1 and (11 ± 5) ml· 100 g-1, respectively; the mean transit time( MTT) was (7.1 ± 2.0) s and (10.4 ± 3.5) s, respectively; the hepatic arterial fraction (HAF) was ( 24 ± 5) % and ( 37 ± 6)% , respectively; the hepatic arterial perfusion (HAP) was(27 ±6) ml·100 g-1·min-1 and (35 ±5) ml·100 g-1·min-1, respectively; the portal venous perfusion (PVP) was (85 ± 13) ml·100 g-1·min-1 and (61 ±11) ml·100 g-1·min-1, respectively.There was significant difference in all parameters between the two groups except the parameter BV(P < 0.05).③ In PHT group, the PVP and BF were negatively correlated with the portal vein pressure, while positively correlated with MTT and HAF.Portal vein pressure was negatively correlated with PVP, the equation, Y = 36.624 -0.219X, was deduced with linear regression analysis, by which the portal vein pressure in PHT Beagles was ( 23.2 ± 2.4) cm H2O, which was correlated with the observed by laparotomy value (23.1 ± 2.8) cm H2O (r = 0.843, P < 0.05).Conclusion CT perfusion is a new non-invasive and effective method for assessment of portal vein pressure.
10.Drug resistance characteristics and spatial clustering of Mycobacterium tuberculosis in Qinghai Province from 2016 to 2019
WANG Xingbin ; JIANG Mingxia ; MA Yongcheng ; ZHANG Zuhao ; HUANG Qiuli ; WANG Ling ; LIU Kuangyi ; ZHANG Yaxin ; WANG Zhaofen
China Tropical Medicine 2023;23(8):815-
Abstract: Objective To analyze the resistance and spatial distribution of Mycobacterium tuberculosis (MTB) to six commonly used anti-tuberculosis drugs in Qinghai Province from 2016 to 2019, so as to provide a reference for tuberculosis treatment and drug-resistant tuberculosis control. Methods A total of 1 182 identified strains of Mycobacterium tuberculosis in Qinghai Province from 2016 to 2019 were collected, and 6 anti-tuberculosis drugs were subjected to drug susceptibility tests and strain confirmed by the proportional method. By means of ArcMap10.7 and SaTScan10.1 software, map visualization, spatial autocorrelation analysis and spatial scanning of MTB drug resistance were performed to identify MTB drug resistance clusters in Qinghai Province. Results From 2016 to 2019, the total drug resistance (TDR) rate of 1 182 Mycobacterium tuberculosis strains in Qinghai Province was 23.77% (281/1 182), with a mono-resistance (MR) rate of 11.08% (131/1 182), a poly-resistance (PDR) rate of 3.89% (46/1 182), a multi-drug resistance (MDR) rate of 8.80% (104/1 182), and an extensive drug resistance (XDR) rate of 0.85% (10/1 182). The rates of MDR, XDR and TDR all showed a decreasing trend year by year (P<0.01). The drug resistance spectrum displayed 21 combinations. The TDR rate and MDR rate in the retreatment patients were higher than those of the initial treated patients, and the difference was statistically significant (χ2
TDR=22.784, χ2MDR=45.082, P<0.01). In terms of demographic characteristics, the TDR rate in males was higher than that in females, and the middle-aged group was higher than other age groups, and the differences were statistically significant (χ2=7.541, 10.825, P<0.05). The results of global spatial autocorrelation analysis showed that there was no statistical significance in the autocorrelation and obvious spatial clustering of MTB drug resistance in Qinghai Province from 2016 to 2019 (P>0.05), which indicated a random distribution. The results of spatiotemporal scanning showed that there was a kind of clustering area, but the clustering effect was not significant (P>0.05), indicating a random distribution. Conclusions The TDR of MTB in Qinghai Province from 2016 to 2019 showed a downward trend year by year. In comparison with the national average, the rate of multi-drug resistance and extensive drug resistance was still high, and most of the multi-drug resistance resulted from rifampicin and isoniazid. The drugresistant population mainly consisted of retreatment, males, and young and middle-aged pop