1.Progress in research on causes and management of screw perforation after locking plate fixation of proximal humerus fracture
Qiuke WANG ; Ming ZHANG ; Yunfeng CHEN
Chinese Journal of Orthopaedic Trauma 2017;19(7):641-644
Proximal humerus fractures are clinically common upper limb injury,accounting for about 4% to 5% of all human fractures.At present,displaced proximal humerus fractures are often treated by locking plate fixation,but complications may follow.Of them,a locking screw piercing the humeral head has the highest incidence and is thus the most common reason for surgery.Such a screw tends to cause claws of the glenoid cavity,leading to severe pain.Therefore,it is an unavoidable challenge how to effectively prevent postoperative screw piercing for orthopedic surgeons who use locking plating to treat proximal humerus fractures.In this paper,the progress in research will be reviewed on the causes and management of screw perforation after locking plate fixation of proximal humerus fracture.
2.Therapeutic efficacy of percutaneous compression plate internal fixation in treatment for elderly patients with interchanteric fractures
Chuanzhi ZHANG ; Li LIU ; Zhiping KUANG ; Honghui CAO ; Qiuke XIAO ; Jiajun WANG ; Weizhong LU
Journal of Regional Anatomy and Operative Surgery 2013;(6):615-616,619
Objective To explore the therapeutic efficacy of percutaneous compression plate internal fixation in the treatment for elder-ly patients with interchanteric fractures. Methods All 17 patients with interchanteric fractures from March 2012 to January 2013 were trea-ted with percutaneous compression plate internal fixation(Fracture classification:type A1. 2 with 3cases,A1. 3 with 4cases,A2. 1 with 6 ca-ses,A2. 2 with 3 cases,A2. 3 with 1 case). After operation,the patients did functional exercises at the early stage. Then the efficacy were e-valuated and analyzed. Results Operation time was 30~80 min,with average time 50 min, blood loss was (40~100) mL,with average volume 60 mL,time of X-ray exposure was 12~22 s,with average time 20 s. All 17 patients were followed up for 3~18 months. Postoperative function were evaluated according to Harris Hip Score,15 cases were excellent,and 2 cases were good,the excellent and good rate was 100%. Conclusion Percutaneous compression plate internal fixation is suitable for the elderly patients of interchanteric fractures,with shorter oper-ation time,less blood loss,reliable fixation and less complications.
3.Pre-contouring long helical plate of proximal humerus internal locking system aided by 3D-printing technique in minimally invasive plate osteosynthesis for metadiaphyseal fractures of the proximal humerus: a cadaveric study and clinical experience
Qiuke WANG ; Moran HUANG ; Yunfeng CHEN ; Lei WANG
Chinese Journal of Orthopaedic Trauma 2018;20(11):940-945
Objective To identify the anatomic advantages of pre-contouring long helical plate of proximal humerus internal locking system (PHILOS) aided by 3D-printing technique in minimally invasive plate oseoynthesis (MIPO) for metadiaphyseal fractures of the proximal humerus.Methods Firstly in a cadaveric study,12 fresh frozen samples of upper extremity were divided into 2 equal groups:6 in a Synbone group and 6 in a 3D-printing group.Long 10-hole PHILOS plates were pre-contoured helically according to Synbone humerus models in the Synbone group but according to 3D-printing humerus models in the 3D-printing group.All these helical plates were fixed onto the cadaveric humerus using MIPO technique respectively.The horizontal distances between the radial nerve and the lateral side of the plate were measured at the point where the radial nerve penetrates the muscular septum,at the 6th hole on the plate and at the distal end of the plate;the distance between the medial side of the distal plate and the upper arm neurovascular bundle was also measured.Finally,the full lengths of all these cadaveric humeri were measured.Secondly,on the basis of the anatomic study,16 patients with metadiaphyseal fracture of the proximal humerus were treated at Department of Orthopedic Surgery,The Sixth People's Hospital of Shanghai from February 2013 to March 2016,using the same MIPO technique and the same long 10-hole PHILOS plates pre-contoured helically on the 3D printing models which were mirrored on the humerus on the healthy side of the patients.They were 4 men and 12 women,aged from 59 to 87 years (mean,71.0 years).By the AO/OTA classification,10 cases were type B and 6 type C.The fracture line involved the proximal humerus in 7 cases.Postoperative complications were followed up.At the final follow-up,the shoulder function was assessed according to the Constant-Murley score and the elbow function according to the Mayo Elbow Performance Score (MEPS).Results By the anatomic measurement,the full length of cadaveric humerus averaged 30.17 ± 1.93 cm in the Synbone group and 29.75 ± 2.17cm in the 3D-printing group,showing no significant difference (P > 0.05).The horizontal distances between the radial nerve and lateral side of the plate at the point where the radial nerve penetrates the muscular septum,at the 6th hole on the plate and at the distal end of the plate in the Synbone and 3D-printing groups were,respectively,11.50 ± 0.92 mm versus 17.87 ± 1.88 mm,6.90 ± 1.78 mm versus 14.83 ± 1.50 mm,and 5.14 ± 1.14 mm versus 8.36 ± 1.27 mm,all showing significant differences between the 2 groups (P < 0.05%).The distance between the medial side of the distal plate and the upper arm neurovascular bundle was 6.25 ± 0.95 mm in the Synbone group and 6.88 ± 1.21 mm in the 3D-printing group,showing an insignificant difference between the 2 groups (P > 0.05).The clinical observation found no iatrogenic nerve injury.The 16 patients were followed up for an average of 25.3 months (range,from 24 to 38 months).All fractures got united uneventfully.At the final follow-up,their Constant-Murley scores averaged 77.6 points and their MEPS 96.5 points.Conclusion The risk of iatrogenic injury to the radial nerve can be lowered when 3D-print technique is applied for helical pre-contouring of long PHILOS plate in the MIPO for metadiaphyseal proximal humeral fractures,leading to satisfactory clinical results.
4.Study of Extracts from Bushen Huoxue Decoction in Promoting Proliferation of Rat Bone Marrow Mesenchymal Stem Cells
Yongquan HUANG ; Yiwen LUO ; Bin WANG ; Nianhong HU ; Dongfeng CHEN ; Xunchao ZHANG ; Yan CAI ; Wangyang LI ; Mincong HE ; Qiuke HOU ; Zhiming XU ; Yamei LIU
Journal of Guangzhou University of Traditional Chinese Medicine 2015;(1):86-91
Objective To screen the active components of Bushen Huoxue Decoction ( BSHXD) involved in promoting the proliferation of bone marrow mesenchymal stem cells ( MSCs). Methods BSHXD and its subdivisions were extracted with petroleum ether, ethyl acetate, water-free ethanol and water respectively. MSCs were isolated and cultured by the bone marrow adherent method. At the third passage, MSCs were identified by the specific surface markers with immunofluorescence, and their osteogenic and adipogenic differentiation were tested by alizarin red staining and oil red “O” staining. After treated with the extracts of BSHXD and its subdivisions at gradient concentrations for 24 hours, cell viability was detected by methyl thiazolyl tetrazolium (MTT) assay for the screening of active components and optimal concentration. MTT assay was used to describe the growth curve of MSCs treated with the most effective components, and cell cycle was analyzed by flow cytometry. Results Compared with the blank control group, the extracts of BSHXD and its subdivisions could protect MSCs from death to various degrees. Of all the extracts, the ethyl acetate extract of Bushen Division ( BSD) , ethyl acetate extract of BSHXD, ethyl acetate extract of Huoxue Division ( HXD) had the strongest effect, and the effect was dose-dependent, 100 μg/mL being the optimal active concentration while having no any cytotoxic reaction. The results of MTT assay revealed that BSD extracts promoted the proliferation of MSCs significantly and was the most effective component, and then came BSHXD. The results of flow cytometry indicated that BSD extract had the most strongest effect on increasing the amount of MSCs at proliferative phase, and then came BSHXD. Conclusion BSD ethyl acetate extract is the active component of BSHXD for promoting the proliferation of MSCs, showing an effect on increasing the proportion of MSCs at proliferative phase.
5.Locking plate plus endosteal fibular allograft augmentation for proximal humeral fractures with comminuted medial column
Tuerxun MAIMAITIAILI ; Langqing ZENG ; Ye LU ; Shengbao CHEN ; Yu ZHU ; Yuchen WANG ; Qiuke WANG ; Yifei LIU ; Yunfeng CHEN
Chinese Journal of Orthopaedic Trauma 2017;19(11):928-934
Objective To evaluate the clinical and radiographic outcomes of locking plate plus endosteal fibular allograft augmentation for unstable proximal humeral fractures with comminuted medial column.Methods We retrospectively analyzed the 48 patients who had been treated by locking plate plus endosteal fibular allograft augmentation and fully followed up for unstable proximal humeral fractures with comminuted medial column between June 2014 and March 2016.They were 12 men and 36 women,with an average age of 64.3 years (from 33 to 87 years).By the Neer classification,7 cases were two-part fractures,21 three-part fractures and 20 four-part fractures.Postoperative assessments included Constant-Murley scores,shoulder scores of Quick Disabilities of the Arm,Shoulder and Hand (Quick DASH),Short Form Health Survey (SF12),humeral head height loss,change in humeral neck shaft angle,postoperative complications and revision rate.Results Their follow-ups averaged 16.7 months (from 12 to 30 months).Their final follow-ups showed a mean Constant score of 83.3 (from 67 to 98),a mean DASH shoulder score of 18.9 (from 6.6 to 49.9),and a mean SF12 of 82.8 (from 56 to 98).Postoperatively,the humeral head height loss averaged 1.2 mm (from 0.1 to 3.4 mm) and the neck-shaft angle 3.1° (from 0.1° to 9.1°).Complications happened in 5 cases (10.4%):loss of reduction in one and screw penetration out of the articular surface in 4.Conclusion Locking plate along with endosteal fibular strut allograft augmentation is a promising technique for the treatment of proximal humeral fractures with comminuted medial column because fibular strut allograft may enhance mechanical stability of the humeral head,maintain fracture reduction,reduce humeral head height loss and complications to ensure good clinical outcomes.
6.Research progress on animal models for the evaluation of diarrhea-predominant irritable bowel syndrome
Jiahe ZHANG ; Wang ZHU ; Danting SHEN ; Xiling YANG ; Fengbin LIU ; Qiuke HOU
Acta Laboratorium Animalis Scientia Sinica 2024;32(2):238-247
Irritable bowel syndrome(IBS)is one of the most common functional gastrointestinal disorders,of which diarrhea-predominant IBS(IBS-D)accounts for the largest proportion.The pathogenesis of IBS-D is complicated and diverse,and there is currently a lack of clinically effective drugs.The establishment of animal models is an essential tool for further studies of the disease mechanisms,evaluation of clinical efficacy,and drug development,and the preparation and evaluation standards of models are important factors affecting the quality of the research.Based on the currently accepted pathogenesis of IBS-D and the previous modeling experience of our research group,this review systematically summarizes the evaluation method used in animal models of IBS-D in terms of diarrhea observation,visceral sensitivity tests,and intestinal motility tests,to provide a reference for future studies.