1.Influence of Nursing Intervention on Postpartum Adverse Emotions and Breastfeeding Compliance in Primipara
Meiping ZHAO ; Youfeng WU ; Qiuhui HUO ; Jian ZHONG ; Mei LUO ; Jun YAN ; Aiqin JIANG
Journal of Kunming Medical University 2016;37(8):143-146
Objective To observe the influence of nursing intervention on postpartum depression and breastfeeding compliance in primipara.Methods From August 2013 to April 2015,146 women received cesarean section in North Jiaochang Branch of Hanzhong Central Hospital were randomly divided into intervention group and control group with 73 cases in each group.The control group was treated with routine nursing measures,and the intervention group with both routine care and nursing intervention.Self-Rating Depression Scale (SDS) and Self-Rating Anxiety Scale (SAS) were used to evaluate the negative emotions of maternal postpartum.Breastfeeding Self-Efficacy Scale (BSES) were used to evaluate the confidence of maternal breast feeding.The breast feeding compliance between the two groups was compared.The breast feeding rates of the two groups were compared in 1 week and 1 month after discharge.Results Compared with the control group,the SDS and SAS scores of the intervention group were significantly lower (P<0.05).The breastfeeding confidence of the intervention group was significantly better than the control group and the difference was statistically significant (P<0.05).The compliance of breast feeding of the intervention group was 97.26% significantly higher than that of the control group (78.08%)with a statistically significant difference (P<0.05).After one-week and one-month follow-up,the rate of breastfeeding of the intervention group was significantly higher than that of the control group (95.89% VS 83.56%;91.78% VS 72.60%,P<0.05).Concltsion The nursing intervention measures for primipara after cesarean section can significantly break bad mood,enhance maternal breastfeeding confidence,increase the rate of breastfeeding compliance and are worthy of promotion.
2.Platelet parameter determination of the patients with uterine cervical cancer and its clinical significance
Wenjuan WU ; Fangjing ZHENG ; Yikuang LIN ; Honghua LAI ; Qiuhui YE
Cancer Research and Clinic 2018;30(6):388-390,395
Objective To investigate the level of platelet parameter of uterine cervical cancer patients and its clinical significance. Methods Seventy-four cases with cervical cancer (the observation group) from Ningde Municipal Hospital, the Affiliated Hospital of Fujian Medical University from May 2014 to May 2016 were chosen as the research subjects. Seventy-four cases of healthy people were treated as the control group. According to the International Federation of Gynecology and Obstetrics (FIGO), the observation group was divided into 15 cases under stage ⅡB(the early stage group), 59 cases of ⅡBstage and above (the middle and advanced stage group). Platelet count (Plt) and mean volume of platelet were monitored and compared by using Japan automatic blood cell analyzer. Results Plt in the observation group was higher than that in the control group [(266 ±71) × 109/L vs. (215 ±42) × 109/L, respectively], and the difference was statistically significant (t = 5.322, P< 0.05). The average volume of platelet in the observation group was lower than that in the control group [(9.2±1.2) fl vs. (9.9±1.3) fl, respectively], and the difference was statistically significant (t =-3.931, P < 0.05); There was no statistical difference in the Plt and mean volume of platelet between the early stage group and the middle and advanced stage group (both P>0.05). Conclusions The determination of platelet parameter has a certain clinical significance for screening and early detection of uterine cervical cancer.
3.Evaluation of the performance of systems for whole blood C-reactive protein detection: a multi-center study
Juan CHENG ; Huaiyuan LI ; Haipeng LIU ; Yuxin WANG ; Jin XU ; Shangyang SHE ; Wei QU ; Yidong WU ; Guixia LI ; Junmei YANG ; Liya MO ; Yun XIANG ; Jiangwei KE ; Liyue KUI ; Lei ZHENG ; Hongbing CHEN ; Zhili YANG ; Xin LYU ; Hong ZHANG ; Zhenhua TANG ; Lijuan MA ; Hongquan LUO ; Xiangyang LI ; Wenli ZHANG ; Hui JIA ; Huiming YE ; Lijun TIAN ; Qiuhui PAN
Chinese Journal of Laboratory Medicine 2021;44(7):633-643
Objective:To explore the performance of the commonly used whole blood C-reactive protein (CRP) detection systems and give related recommendation on the performance requirements of detection systems.Methods:A total of 7 540 venous blood samples from 26 maternal, child and children′s hospitals were collected to conduct this multi-center study on the analytical performance of 5 commonly used whole blood CRP detection systems from March to April in 2019. The blank check, carryover, repeatability, intermediate precision, linearity, sample stability, influence of hematocrit/triglyceride/bilirubin, comparison with SIEMENS specific protein analyzer and trueness were evaluated. The 5 systems included BC-5390CRP autohematology analyzer, AstepPLUS specific protein analyzer, Ottoman-1000 Automated Specific Protein POCT Workstation, i-CHROMA Immunofluorometer equipment Reader and Orion QuikRead go detecting instrument. The 5 systems were labeled as a, b, c, d and e randomly.Results:Within the 5 systems, all values of blank check were less than 1.00 mg/L, the carryovers were lower than 1.00%. The repeatability of different ranges of CRP concentrations including 3.00-10.00, 10.00-30.00 and>30.00 mg/L were less than 10.00%, 6.00% and 5.00%, respectively, and the intermediate precision was less than 10.00%. The linearity correlation coefficients of the 5 systems were all above 0.975, while the slope was within 0.950-1.050. Whole blood samples were stable within 72 hours both at room temperature (18-25 ℃) and refrigerated temperature (2-8 ℃). The CRP results were rarely influenced by high triglyceride or bilirubin, except for the immmunoturbidimetric test based on microparticles coated with anti-human CRP F(ab) 2 fragments. When triglyceride was less than 15.46 mmol/L, the deviation of CRP was less than 10.00%. When bilirubin was less than 345.47 μmol/L, the deviation of CRP was less than 10.00%. CRP was more susceptible to Hct on the systems without Hct correction. The deviation of CRP between different Hct dilution concentration and 40% dilution concentration can reach as high as 67.48%. The correlation coefficients ( r) of 5 systems were all more than 0.975 in the range of 0-300.00 mg/L compared with Siemens specific protein analyzer. All systems passed the trueness verification using the samples with specified values of 12.89 and 30.60 mg/L. Conclusion:The performance of 5 systems can basically meet the clinical needs, but it is suggested that the whole blood CRP detection system without automatic Hct correction should be modified manually.
4.Pediatric reference intervals for plasma and whole blood procalcitonin of in China: a multicenter research
Zhan MA ; Fangzhen WU ; Jiangtao MA ; Yunsheng CHEN ; Guixia LI ; Jinbo LIU ; Hongbing CHEN ; Huiming YE ; Xingyan BIAN ; Dapeng CHEN ; Jiangwei KE ; Haiou YANG ; Lijuan MA ; Qiuhui PAN ; Hongquan LUO ; Xushan CAI ; Yun XIE ; Wenqi SONG ; Lei ZHANG ; Hong ZHANG
Chinese Journal of Laboratory Medicine 2022;45(6):581-588
Objective:To establish the biology reference interval (RI) of peripheral blood procalcitonin (PCT) for children between 3 days and 6 years old in China.Methods:Totally 3 353 reference individuals with apparent health or no specific diseases were recruited in 18 hospitals throughout the country during October 2020 to May 2021. Reference individuals were divided into four groups: 3-28 days, 29 days - 1 year, 1-3 years and 4-6 years. Vein blood or capillary blood were collected by percutaneous puncture from every reference individual. The PCT level in serum and the capillary whole blood were assayed by Roche Cobas e601 and Norman NRM411-S7 immunoanalyzer. Outliers were deleted and 95th percentiles of every group were provided as RIs. Man-Whitney U test or Kruskal-Wallis test were used performed to assess the difference among different gender, age or method groups. Results:The difference of PCT distribution between male and female is not statistically significant, but the difference between serum and capillary whole blood is statistically significant. The differences between age groups are significant too. For Roche e601, serum PCT RI of 3-28 days group is <0.23 μg/L, 29 days - 6 years are <0.11 μg/L. For NRM411, Serum PCT RI of 3-28 days group is <0.21 μg/L, 29 days - 1 year: <0.09 μg/L, 1 - 6 years: <0.10 μg/L. For whole blood PCT, RI of 3-28 days group is <0.26 μg/L, 29 days - 6 years is <0.15 μg/L.Conclusions:Serum and capillary whole blood PCT have different RIs, however, capillary whole blood PCT testing is valuable in pediatric application. Children in 3-28 days show higher PCT levels than other age group. To establish the RIs and understand the differences among different groups are essential for the interpretation and clinical application of peripheral blood PCT testing results.
5.Establishment of hierarchical management standard in patients with chronic obstructive pulmonary disease from the perspective of pharmacists based on Delphi method
Ruobin ZHANG ; Qiuhui WU ; Xinrui CAO ; Congling CHEN ; Jinping ZHANG
China Pharmacy 2024;35(7):860-865
OBJECTIVE To develop a standard of hierarchical management for patients with chronic obstructive pulmonary disease (COPD) from the perspective of pharmacists. METHODS The triangle hierarchical management model was used as the framework. Through literature research, the indicators of the hierarchical management standard for COPD patients were preliminarily compiled. A questionnaire was designed and administered to 18 experts, and Delphi method was conducted in two rounds to determine the contents of the standard. RESULTS The response rates for both rounds of expert consultation were 100%, with both authority coefficients of experts of 0.903 and Kendall coordination coefficiens of 0.279 and 0.189 for each indicator. The final established standard of hierarchical management for COPD patients included 25 stratified indicators and 17 pharmaceutical hierarchical management indicators. There were 9, 8 and 8 indicators in the high-risk, medium-risk, and stable layers, respectively, considering three aspects: disease, medication, and self-management level. The corresponding first-level, second- level, and third-level pharmaceutical management included 6, 6 and 5 indicators, respectively, including inhalation technical guidance, medication adherence guidance, treatment monitoring, and follow-up, etc. CONCLUSIONS The standard of hierarchical management for COPD patients established by Delphi method is scientific and reliable, which can provide a reference for pharmacists to carry out hierarchical management of COPD patients in China.