1.Comparison of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer
Wei, QIU ; Yanjun, HUA ; Zequan, XU ; Qiang, WU
Chinese Journal of Experimental Ophthalmology 2017;35(6):544-547
Background The measurement of corneal Q value is essential for corneal refractive surgery and calculation of intraocular lens during cataract surgery.Topolyzer was often used for the measurement of Q value,and recently Topcon KR-1W and iTrace were applied in ophthalmology.However,whether the measured values are interchangeable is unclear.Objective This study was to assess the difference and consistency of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer.Methods Corneal Q values were measured on 100 right eyes of 100 healthy subjects under the approval of Ethic Committee of the Sixth Hospital Affiliated to Shanghai Jiaotong University and informed consent of each subject from November to December in 2014 with Topcon KR-1W,iTrace and Topolyzer.Three valid measurements were obtained for each device,and the average values from each device were calculated.The difference of the outcomes among the instruments was compared by repeated measures analysis of variance (ANOVA),and the consistency among the outcomes from different apparatus was analyzed by Bland-Altman plots.Results The mean corneal Q values were-0.184-±0.112,-0.117±0.167 and-0.269±0.117 from Topcon KR-1W,iTrace and Topolyzer,respectively,with a significant difference among them (P < 0.001).The measured Q value by Topcon KR-1W was 0.085±0.010 larger than that by Topolyzer,and the Q values by iTrace was 0.152± 0.014 larger than that by Topolyzer,while the Q values obtained by Topcon KR-1W was 0.067±0.016 smaller than that by iTrace (all at P<0.05).The 95% confidence interval of the values between Topcon KR-1W and iTrace,Topcon KR-1W and Topolyzer,iTrace and Topolyzer were-0.106 to-0.028,0.060 to 0.109 and 0.118 to 0.186,respectively.Bland-Altman plots showed that 6%,6% and 5% values were outside of 95% agreement of limit (LoA) between Topcon KR-1W and iTrace,iTrace and Topolyzer or KR-1W and Topolyzer,respectively,with the maximal differences of 0.28,0.43 and 0.38.Conclusions Corneal Q values measured by Topcon KR-1W and iTrace are larger than those measured by Topolyzer.Due to the poor agreements among the corneal Q values by the 3 kinds of devices,they are not interchangeable in clinical applications for the measurement of corneal Q value.
2.Effect of speech therapy on mental health of patients with aphasia
Xu HE ; Jun HONG ; Jian-hua LIN ; Ling QIU
Chinese Journal of Rehabilitation Theory and Practice 2002;8(11):694-695
ObjectiveTo investigate the effect of speech therapy on mental health of patients with aphasia. MethodsCRRCAE and SCL-90 were used to assess the speech and mental state in 28 aphasia patients. All aphasia patients were treated by using speech therapy and the changes before and after treatment were compared. ResultsThe scores in listening comprehension, repetition, naming, reading,reading comprehension, writing and counting were distinctly higher at post-treatment than that at pre-treatment. All SCL-90 factor's levels at post-treatment were distinctly reduced than that at preat post-treatment(P<0.01).Conclusions Speech therapy can improve the language function,as well as mitigate the mental symptoms.
3.Application of Simple Biopsy Clip by Ultrasound-Guided Percutaneous on Renal Biopsy in Children
qiu-qin, XU ; xiao-zhong, LI ; mei-hua, ZHANG ; hua, KUAI
Journal of Applied Clinical Pediatrics 1992;0(05):-
Objective To analyze the safety and diagnostic value of ultrasound-guided biopsy with simple biopsy clip in children.Methods Under simple biopsy clip 52 cases were performed percutaneous renal biopsy.Then the curative rate and the incidence rate of complications were evaluated.Results Of 52 cases,49 cases(94.23%) gained enough renal tissue specimen for histological evaluation;Three failed cases occurred at early stage,nothing was found at later stage.The main complication was macroscopic hematuria occurred only once or twice after the operation and perirenal hematoma in 1.92% of the cases.No other severe complications were found.Conclusions The biopsy clip is convenient and sterile,and can guide the biopsy device exactly and safely.The use of 18-gauge biopsy gun and the automated biopsy device in children can decrease the complication rate,which can be easily performed.
4.Cytotoxicity in Vitro of a Noval Ni-free ZrCuFeAlAg Bulk Metallic Glass.
Huifang PANG ; Cong XU ; Hua QIN ; Demin LI ; Peiyuan LI ; Bo WANG ; Shujuan ZHANG ; Qiu ZHAO
Journal of Biomedical Engineering 2015;32(2):380-386
This paper is to evaluate the biocompatibility and cytotoxicity of a new Ni-free Zr-based bulk metallic glass (BMG), Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3, by comparing it with conventional Ti6Al4V alloy. According to ISO 10993-5: 1999 and GB/T 16886.5-1997 standards, Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3, pure Zr and Ti6Al4V materials were extracted with surface area of sample/volume of medium ratio being 1 cm2/mL and 0.5 cm2/mL, respectively. The viabilities of MG-63 cells (Human osteosarcoma cell line) cultured in the BMG medium extracts for 1, 3 and 5 days were determined by CCK-8 assay. The cellular morphology of MG-63 cells cultured on the surface of samples for 3 days was tested through laser scanning confocal microscopy (LSCM) and scanning electron microscopy (SEM). The relative growth rate (RGR) of MG-63 cells cultured in Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3 and pure Zr were both more than 85%, indicating that the cytotoxicity of BMG was relatively low and met the national biomedical material eligibility standard. There was insignificant difference in the morphology of MG-63 cells cultured in the BMG medium extracts and the control group through LSCM and SEM, which showed the BMG had excellent biological compatibility. The Zr-based bulk metallic glass Zr60.14 Cu22.31 Fe4.85 Al9.7 Ag3 and the conventional Ti6Al4V alloy both had no obvious cytotoxicity to MG-63 cells. These results provided evidence that the new Zr-based bulk metallic glass could be potential replacement material for the orthopedic surgical implant.
Alloys
;
Biocompatible Materials
;
Cell Line
;
Glass
;
Humans
;
Microscopy, Electron, Scanning
;
Nickel
;
Titanium
;
Zirconium
5.Clinical assessment of modified early warning score and SMART-COP on predicting mechanical ventilation in patients with severe influenza A H1N1
Jianru XU ; Liqun SHI ; Jun QIAN ; Hua LIU ; Bin QIU ; Xudong HAN ; Xiaoying HUANG
Chinese Journal of Infectious Diseases 2011;29(4):232-235
Objective To evaluate the predictive value of modified early warning score (MEWS) and SMART-COP score on mechanical ventilation in patients with severe influenza A H1N1. Methods Fifty cases diagnosed with severe influenza A H1N1 were retrospectively analyzed. The MEWS and SMART-COP score were calculated. The area under the receiver operating characteristic (ROC) curve (AUC) was evaluated using ROC curve. MEWS, SMART-COP score and AUC were analyzed by Z test. Results The AUCs of MEWS and SMART-COP score for predicting mechanical ventilation were 0. 923 and 0. 889, respectively, which were not significantly different (Z=0. 548, P =0. 584).Conclusion Both of MEWS and SMART-COP score are predictive factors of mechanical ventilation in the patients with severe influenza A H1N1.
6.A survey on status of diabetes-related knowledge among general physicians in Shanghai Pudong New Area
Chunyan ZHAO ; Yafang NI ; Xiaonan RUAN ; Hui HUANG ; Hua QIU ; Xu LI ; Weiqun LIU ; Bo FENG
Chinese Journal of General Practitioners 2010;9(4):274-275
To evaluate the status of diabetes-related knowledge and training requirement among general physicians,a questionnaire survey was conducted in 676 general physicians from 32 primary medical institutions and 5 secondary hospitals of Shanghai Pudong New Area.48.2% (261/541) of the surveyees had bachelor degree and most of them worked in secondary hospitals or primary medical institutions in affluent areas.The awareness rate of diabetic knowledge among the surveyeos was 51.6%,and there were significant differences in the awareness rate of diabetes-related knowledge between different levels of hospitals and physicians with different academic background.Only 26.6% of physicians received diabetes-related continuing education or training,there was a popular request for professional training from the surveyed physicians.
7.Study on histocompatibility of pinealocyte microencapsules
Hua LIAO ; Dachuan XU ; Lei YU ; Xiaozhong QIU ; Xiaojing LIU ; Meixian HUANG
Chinese Journal of Pathophysiology 2000;0(10):-
AIM: To explore the histocompatibility of pinealocyte microencapsules in vivo. METHODS: The pineal glands of neonatal rats were removed under operating microscope and pinealocytes were isolated through collagenase and trypsin digestion. Pinealocytes were cultured for one week in vitro and collected immediately after digesting was encapsulated in APA microencapsules. The cells and empty capsules were transplanted into abdominal cavity or intermuscular space respectively and retrieved at the 15th or 30th day after operation. Morphological observation, HE staining, cell counting, and HPLC technique were used to analyze the shape, proliferation and function, the degree of inflammation fibrosis of retrieved microencapsules. RESULTS: The retrieve rate of cell capsule from abdominal cavity was about 85 % . The retrieved capsules had integrated profile mostly although some were damaged. The amount of macrophages attached to capsule wall and the thickness of wall increased gradually following the period of transplantation. However, the retrieve rate, wall thickness had no difference between retrieved cell and empty capsules at the same time. Secretion ability of pinealocytes in capsule retrieved at 15th day after operation decreased rapidly and those retrieved at 30th day after operation lossed secretion function. CONCLUSION: APA microencapsules had histocompatibility relatively in vivo and protected pinealocytes in capsule from immunologic rejection of the host. The survival time was about 20 days. During this period cells in capsule maintained activity and MT secretion ability.
8.Effects of cobalt chloride mimetic hypoxia on the proliferation, apoptosis and migration of human pancreatic cancer cell line PANC1
Liang ZHU ; Shengnan XU ; Huifang PANG ; Huizhen ZHAO ; Hua QIN ; Peiyuan LI ; Demin LI ; Qiu ZHAO
Chinese Journal of Pancreatology 2012;12(2):111-114
ObjectiveTo investigate the influence of cobalt chloride ( CoCl2 )-mimetic hypoxia on theproliferation,apoptosis and migration of human pancreatic cancer cell fine PANC1.MethodsPANC1 cells were treated with 0(control),100,200,400,800 μmol/L CoCl2 respectively for 24 h.Real-time RT-PCR and Western blot were used to determine hypoxia induced factor ( HIF)-1o mRNA and protein expression respectively,and cell counting kit-8(CCK-8) assays,flow cytometry and cell scratch test were used to examine the proliferation,apoptosis and migration of PANC1 cells,respectively.ResultsIn the control group and 100,200,400 and 800 μmol/L CoCl-2 groups,the expressions of HIF-1t mRNA were 1,1.08 ±0.12,1.12 ± 0.09,1.04±0.11,0.66 ±0.07,and the expressions of VEGF mRNA were 1,2.69±0.35,4.81 ±0.54,2.19 ± 0.21,0.79 ± 0.08,while the expressions of HIF-1 α protein were 0.23 ± 0.03,0.36 ± 0.04,1.15 ± 0.11,1.08 ± 0.09,0.44 ± 0.04; and the expressions of VEGF protein were 0.14 ± 0.02,0.12 ± 0.01,0.95 ±0.09,0.87 ±0.09,0.55 ±0.06; and cell viability rates were 100%,(98.43 ±2.88)%,(76.15 ± 0.70)%,(53.87 ±0.77)%,(35.23 ±0.67)% ; while cell apoptotic rates were (5.2 ±1.12)%,(5.74 ± 1.07)%,(6.82 ± 1.85)%,(12.09 ±3.53)%,(31.88 ±6.95)% ; the cell migration distance of PANC1 cells were (43.24 ±3.67)%,(59.46 ±5.39)%,(80.56 ±8.05)%,(63.89 ±5.96)%,(9.09 ± 1.59 ) %.Compared with those of control group,the expressions of VEGF mRNA,VEGF and HIF-1 α protein,cell migration distance showed a two-way variation ( ascending first and descending later) (P <0.05 ),and the expression of HIF-1α mRNA and cell proliferation rate was decreased in a dose-dependent manner,while the cell apoptosis was increased in a dose-dependent manner.Conclusions CoCl2 significantly inhibits the proliferation and promotes apoptosis of PANC1 cells at certain level.CoCl2 has a two-way effect on the migration of PANC1 cells,and it may be related to the direct injury of high concentration of CoCl2 on cells.
9.The expression and significance of serum CA-125 in patients with Budd-Chiari Syndrome
Delei CHENG ; Hao XU ; Rong HUA ; Huan QIU ; Weifu LYU ; Maoheng ZU ; Qingqiao ZHANG
Chinese Journal of Hepatobiliary Surgery 2014;20(9):639-643
Objective To investigated the serum level of carcinoma antigen 125 (CA-125) and its clinical significance in patients with Budd-Chiari syndrome.Methods We reviewed medical records and laboratory tests of patients with BCS first diagnosed in our hospital between August 2011 and April 2013.235 patients were included as experiment group,while 120 healthy adult volunteers were randomly selected as control group.The serum level of CA-125 were detected by electrochemilumescence immunization assay in this single-center retrospective control study.Results The average serum level of CA-125 in experiment group is higher than that of control group [(147.9 ±246.6) kU/L vs (16.0 ±7.2) kU/L,P <0.001].In experiment group,the relative coefficient for serum CA-125 with ascites,alanine aminotransferase,aspartate aminotransferase,albumin and Rotterdam BCS scores was 0.79,0.45,0.29,-0.393 and 0.71,respec tively,P <0.001.As of October 2013,we found that the 68 BCS patients with serum CA-125 level 5-fold higher than the upper limit of normal (> 175 kU/L) presented much lower survival rates and asymptomatic survival rates than the rest 167 BCS patients after intervention therapy:(95.6% and 79.8%) vs (98.8% and 92.0%),P < 0.05.Conclusions The serum level of CA-125 in BCS patients have positive correlation with ascites volume,liver injury degree and Rotterdam BCS scores.Serum CA-125 evaluation appears to be a valuable examination option in BCS as CA-125 levels negatively correlate with worse prognosis,thus could be applied as an efficient tool for prognostication.
10.Premature ovarian failure treated with acupoint catgut implantation and artificial periodic therapy: a randomized controlled trial.
Wei-Dong LI ; Hua-Qun XU ; Jing-Qiang TANG ; Hai-Song QIU
Chinese Acupuncture & Moxibustion 2014;34(1):29-33
OBJECTIVETo compare the difference in the clinical efficacy on premature ovarian failure (POF) between the acupoint catgut implantation combined with artifical periodic therapy and the simple artificial periodic therapy and explore its effect mechanism.
METHODSSixty-five patients of POF were randomized into the two groups. In a western medication group, 32 cases were treated with the artificial periodic therapy with the oral administration of medroxyprogesterone acetate tablets. In a catgut implantation + western medication group, 33 cases were treated with the acupoint catgut implantation combined with artificial periodic therapy. The acupoints of Neiguan (PC 6), Zusanli (ST 36), Guanyuan (CV 4) and Sanyinjiao (SP 6) were selected. The treatment was lasted for half a year and the follow-up visit was for another half a year in the two groups. Kupperman index was used to assess the improvements in the clinical symptoms. The levels of serum sexual hormones such as follicle stimulating hormone (FSH) and estradiol (E2) were evaluated of the patients in the two groups before and after treatment. The efficacy was compared between the two groups.
RESULTSThe scores of the clinical symptoms were all significantly improved after treatment and in the follow-up in the two groups (P < 0.01, P < 0.05). In the 6-month follow-up visit after treatment, the result in the catgut implantation + western medication group was better than that in the western medication group (8.17 +/- 1.19 vs 13.68 +/- 1.08, P < 0.01). FSH was reduced after treatment in the two groups (all P < 0.01) and E2 was increased (all P < 0.05). The curative and remarkably effective rates were 75.8% (25/33) and 81.8% (27/22) after treatment and in the follow-up visit in the catgut implantation + western medication group, which were better than 67.9% (19/28) and 53.6% (15/28) in the western medication group separately (P < 0.05, P < 0.01).
CONCLUSIONThe acupoint catgut implantation combined with artificial periodic therapy achieve the remarkable improvements in the clinical symptoms of POF in the patients and the better results as compared with the simple western medication therapy. The combined therapys efficacy is stable and the long-term efficacy is apparently superior. The effect mechanism is related to the improvements in the serum sexual hormone levels.
Acupuncture Points ; Acupuncture Therapy ; Adolescent ; Adult ; Catgut ; utilization ; Female ; Follicle Stimulating Hormone ; metabolism ; Humans ; Primary Ovarian Insufficiency ; metabolism ; therapy ; Prostheses and Implants ; Treatment Outcome ; Young Adult