1.Meta-analysis of dosemetric comparision between helical tomotherapy and intensity-modulated radiotherapy for early-stage postoperative breast cancer
Qinling CUI ; Yan SUN ; Wen ZHONG ; Yanzhi CHEN ; Yuxia ZHAO
Cancer Research and Clinic 2016;28(12):828-832
Objective To compare the dosemetry between helical tomotherapy (HT) and intensity-modulated radiotherapy (IMRT) for early-stage postoperative breast cancer and provide more valuable evidences to the clinical researches. Methods Clinical trails of dosimetric comparing between HT and IMRT for early-stage breast cancer were obtained from PubMed, Embase, Sciencedirect, CNKI, VIP and Wanfang databases, evaluated and analyzed with the Cochrane Collaboration's RevMan 5.2 software. Results 10 studies were included with a total of 135 patients. Compared to IMRT plans, HT plans provided a significantly better conformity index (P<0.000 1), mean (P<0.000 01) and maximal dose (P=0.003) of the planning target volume (PTV). HT plans had a lower heart maximal dose (P=0.005), V20 (P=0.05), V30 (P=0.003), and ipsilateral lung maximal dose (P=0.003), V20 (P=0.02), as while as had a higher contralateral breast V5 (P=0.01), mean (P=0.05) and maximal dose (P<0.000 01). There was no significantly difference between HT and IMRT plans for homogeneity index of PTV, heart V5, V10, mean dose, ipsilateral lung V5, V10, V30, mean dose, contralateral breast V10, contralateral lung mean and maximal dose (all P >0.05). Conclusion Compared to IMRT plans, HT plans have the dosimetry superiority for early-stage breast cancer with significantly better coverage and dose conformity while maintaining lower doses to high risk organs.
2.Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy
YunMeng WANG ; YuanYuan CUI ; JianKun DAI ; ShuangShuang NI ; TianRan ZHANG ; Xin CHEN ; QinLing JIANG ; YuXin CHENG ; YiChuan MA ; Tuo LI ; Yi XIAO
Korean Journal of Radiology 2024;25(10):913-923
Objective:
To prospectively compare single-shot (SS) echo-planar imaging (EPI) and field-of-view optimized and constrained undistorted single-shot multiplexed sensitivity-encoding (FOCUS MUSE) for diffusion-weighted imaging (DWI) in evaluating thyroid-associated ophthalmopathy (TAO).
Materials and Methods:
SS EPI and FOCUS MUSE DWIs were obtained from 39 patients with TAO (18 male; mean ± standard deviation: 48.3 ± 13.3 years) and 26 healthy controls (9 male; mean ± standard deviation: 43.0 ± 18.5 years). Two radiologists scored the visual image quality using a 4-point Likert scale. The image quality score, signal-to-noise ratio (SNR), contrast-tonoise ratio (CNR), and apparent diffusion coefficient (ADC) of extraocular muscles (EOMs) were compared between the two DWIs. Differences in the ADC of EOMs were also evaluated. The performance of discriminating active from inactive TAO was assessed using receiver operating characteristic curves. The correlation between ADC and clinical activity score (CAS) was analyzed using Spearman correlation.
Results:
Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated significantly higher image quality scores (P < 0.001), a higher SNR and CNR on the lateral rectus muscle (LRM) and medial rectus muscle (MRM) (P < 0.05), and a non-significant difference in the ADC of the LRM and MRM. Active TAO showed higher ADC than inactive TAO and healthy controls with both SS EPI and FOCUS MUSE DWIs (P < 0.001). Inactive TAO and healthy controls did not show a significant ADC difference with both DWIs. Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated better discrimination of active from inactive TAO (AUC:0.925 vs. 0.779; P = 0.007). The ADC was significantly correlated with CAS in SS EPI DWI (r = 0.391, P < 0.001) and FOCUS MUSE DWI (r = 0.645, P < 0.001).
Conclusion
FOCUS MUSE DWI provides better images for evaluating EOMs and better performance in diagnosing active TAO than SS EPI DWI. The application of FOCUS MUSE will facilitate the DWI evaluation of TAO.
3.Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy
YunMeng WANG ; YuanYuan CUI ; JianKun DAI ; ShuangShuang NI ; TianRan ZHANG ; Xin CHEN ; QinLing JIANG ; YuXin CHENG ; YiChuan MA ; Tuo LI ; Yi XIAO
Korean Journal of Radiology 2024;25(10):913-923
Objective:
To prospectively compare single-shot (SS) echo-planar imaging (EPI) and field-of-view optimized and constrained undistorted single-shot multiplexed sensitivity-encoding (FOCUS MUSE) for diffusion-weighted imaging (DWI) in evaluating thyroid-associated ophthalmopathy (TAO).
Materials and Methods:
SS EPI and FOCUS MUSE DWIs were obtained from 39 patients with TAO (18 male; mean ± standard deviation: 48.3 ± 13.3 years) and 26 healthy controls (9 male; mean ± standard deviation: 43.0 ± 18.5 years). Two radiologists scored the visual image quality using a 4-point Likert scale. The image quality score, signal-to-noise ratio (SNR), contrast-tonoise ratio (CNR), and apparent diffusion coefficient (ADC) of extraocular muscles (EOMs) were compared between the two DWIs. Differences in the ADC of EOMs were also evaluated. The performance of discriminating active from inactive TAO was assessed using receiver operating characteristic curves. The correlation between ADC and clinical activity score (CAS) was analyzed using Spearman correlation.
Results:
Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated significantly higher image quality scores (P < 0.001), a higher SNR and CNR on the lateral rectus muscle (LRM) and medial rectus muscle (MRM) (P < 0.05), and a non-significant difference in the ADC of the LRM and MRM. Active TAO showed higher ADC than inactive TAO and healthy controls with both SS EPI and FOCUS MUSE DWIs (P < 0.001). Inactive TAO and healthy controls did not show a significant ADC difference with both DWIs. Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated better discrimination of active from inactive TAO (AUC:0.925 vs. 0.779; P = 0.007). The ADC was significantly correlated with CAS in SS EPI DWI (r = 0.391, P < 0.001) and FOCUS MUSE DWI (r = 0.645, P < 0.001).
Conclusion
FOCUS MUSE DWI provides better images for evaluating EOMs and better performance in diagnosing active TAO than SS EPI DWI. The application of FOCUS MUSE will facilitate the DWI evaluation of TAO.
4.Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy
YunMeng WANG ; YuanYuan CUI ; JianKun DAI ; ShuangShuang NI ; TianRan ZHANG ; Xin CHEN ; QinLing JIANG ; YuXin CHENG ; YiChuan MA ; Tuo LI ; Yi XIAO
Korean Journal of Radiology 2024;25(10):913-923
Objective:
To prospectively compare single-shot (SS) echo-planar imaging (EPI) and field-of-view optimized and constrained undistorted single-shot multiplexed sensitivity-encoding (FOCUS MUSE) for diffusion-weighted imaging (DWI) in evaluating thyroid-associated ophthalmopathy (TAO).
Materials and Methods:
SS EPI and FOCUS MUSE DWIs were obtained from 39 patients with TAO (18 male; mean ± standard deviation: 48.3 ± 13.3 years) and 26 healthy controls (9 male; mean ± standard deviation: 43.0 ± 18.5 years). Two radiologists scored the visual image quality using a 4-point Likert scale. The image quality score, signal-to-noise ratio (SNR), contrast-tonoise ratio (CNR), and apparent diffusion coefficient (ADC) of extraocular muscles (EOMs) were compared between the two DWIs. Differences in the ADC of EOMs were also evaluated. The performance of discriminating active from inactive TAO was assessed using receiver operating characteristic curves. The correlation between ADC and clinical activity score (CAS) was analyzed using Spearman correlation.
Results:
Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated significantly higher image quality scores (P < 0.001), a higher SNR and CNR on the lateral rectus muscle (LRM) and medial rectus muscle (MRM) (P < 0.05), and a non-significant difference in the ADC of the LRM and MRM. Active TAO showed higher ADC than inactive TAO and healthy controls with both SS EPI and FOCUS MUSE DWIs (P < 0.001). Inactive TAO and healthy controls did not show a significant ADC difference with both DWIs. Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated better discrimination of active from inactive TAO (AUC:0.925 vs. 0.779; P = 0.007). The ADC was significantly correlated with CAS in SS EPI DWI (r = 0.391, P < 0.001) and FOCUS MUSE DWI (r = 0.645, P < 0.001).
Conclusion
FOCUS MUSE DWI provides better images for evaluating EOMs and better performance in diagnosing active TAO than SS EPI DWI. The application of FOCUS MUSE will facilitate the DWI evaluation of TAO.
5.Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy
YunMeng WANG ; YuanYuan CUI ; JianKun DAI ; ShuangShuang NI ; TianRan ZHANG ; Xin CHEN ; QinLing JIANG ; YuXin CHENG ; YiChuan MA ; Tuo LI ; Yi XIAO
Korean Journal of Radiology 2024;25(10):913-923
Objective:
To prospectively compare single-shot (SS) echo-planar imaging (EPI) and field-of-view optimized and constrained undistorted single-shot multiplexed sensitivity-encoding (FOCUS MUSE) for diffusion-weighted imaging (DWI) in evaluating thyroid-associated ophthalmopathy (TAO).
Materials and Methods:
SS EPI and FOCUS MUSE DWIs were obtained from 39 patients with TAO (18 male; mean ± standard deviation: 48.3 ± 13.3 years) and 26 healthy controls (9 male; mean ± standard deviation: 43.0 ± 18.5 years). Two radiologists scored the visual image quality using a 4-point Likert scale. The image quality score, signal-to-noise ratio (SNR), contrast-tonoise ratio (CNR), and apparent diffusion coefficient (ADC) of extraocular muscles (EOMs) were compared between the two DWIs. Differences in the ADC of EOMs were also evaluated. The performance of discriminating active from inactive TAO was assessed using receiver operating characteristic curves. The correlation between ADC and clinical activity score (CAS) was analyzed using Spearman correlation.
Results:
Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated significantly higher image quality scores (P < 0.001), a higher SNR and CNR on the lateral rectus muscle (LRM) and medial rectus muscle (MRM) (P < 0.05), and a non-significant difference in the ADC of the LRM and MRM. Active TAO showed higher ADC than inactive TAO and healthy controls with both SS EPI and FOCUS MUSE DWIs (P < 0.001). Inactive TAO and healthy controls did not show a significant ADC difference with both DWIs. Compared with SS EPI DWI, FOCUS MUSE DWI demonstrated better discrimination of active from inactive TAO (AUC:0.925 vs. 0.779; P = 0.007). The ADC was significantly correlated with CAS in SS EPI DWI (r = 0.391, P < 0.001) and FOCUS MUSE DWI (r = 0.645, P < 0.001).
Conclusion
FOCUS MUSE DWI provides better images for evaluating EOMs and better performance in diagnosing active TAO than SS EPI DWI. The application of FOCUS MUSE will facilitate the DWI evaluation of TAO.
6.Progress in Survival Prognosis of Segmentectomy for Early-stage Non-small Cell Lung Cancer.
Sunyin RAO ; Lianhua YE ; Xin CUI ; Qinling SUN ; Run CAO ; Shouyong XIAO ; Jichen YANG ; Wei WANG ; Guangqiang ZHAO ; Yunchao HUANG
Chinese Journal of Lung Cancer 2020;23(9):830-836
Surgery is currently the most appropriate treatment for early-stage non-small cell lung cancer (NSCLC). Increasing unilateral or bilateral multiple primary lung cancer being found, segmentectomy has attracted wide attention for its unique advantages in the treatment for such tumors. Ground glass opacity dominant early-stage NSCLC is associated with a good prognosis and can be cured by segmentectomy, however, the treatment of solid-dominant NSCLC remains controversial owing to the invasive nature. With the in-depth study on the lymph node metastasis pathway, radiological characteristics and molecular biology of NSCLC, a large part of solid nodules with certain characteristics can also be cured by segmentectomy. This paper reviews the research status and progress about the indication of segmentectomy.
.