1.THE IMPACT OF THREE GORGE DAM (TGD) CONSTRUCTION ON THE SCHISTOSOMIASIS TRANSMISSION IN JIANGHAN PLAIN——THE RELATIONSHIP BETWEEN AGRICULTURE STRUCTURE AND SCHISTOSOMIASIS TRANSMISSION
Chinese Journal of Schistosomiasis Control 1992;0(06):-
A typical lake region with serious schistosomiasis endemic areas was selected as the study field. In the study,the 10 years (1985 - 1994) data about the agriculture sturcture and schistosomiasis prevalence was collected and analyzed. The results showed significant posi-tive correlationships among the infection rate,the total area of snail habitat and paddy field. The infection rate of human had a close relation to the infection rate of domestic animals.
2.Imaging findings of primary synodal sarcoma of the lung
Yubao GUAN ; Yingying GU ; Ling CHEN ; Qingsi ZENG ; Xiaotao ZHENG ; Huai CHEN ; Chaoliang ZHANG ; Renli CEN
Chinese Journal of Radiology 2009;43(8):813-816
r diagnosing the disease to combine pathology, immunohistochemistry and SYT-SSX gene detection.
3.Parameters of quantitative multi-slice CT imaging technology in pulmonary
Huai CHEN ; Qingsi ZENG ; Yubao GUAN ; Yi GAO ; Jinping ZHENG ; Xinran HOU
Chinese Journal of Medical Imaging Technology 2010;26(2):351-354
Objective To evaluate the relevance of MSCT pulmonary function parameters and pulmonary function test (PFT) parameters, and to define the reference value of MSCT pulmonary function parameters. Methods Thirty male volunteers received clinical PFT and MSCT scan. MSCT scan was perfomed at the end of the maximum inspiratory and maximum expiratory. All data were analyzed with the lung analysis software of computer-aided inspection system correlatedly with pulmonary function parameters. Results The lung volume at full inspiratory volume (Vin) and full expiratory volume (Vex) in MSCT scan had good correlation with total lung capacity (TLC) and residual volume (RV) (r=0.90, P<0.01; r=0.74, P<0.01). Vex/Vin was correlated with RV/TLC (r=0.74, P<0.01), and Vin-Vex was correlated with MVC (r=0.85, P<0.01). In inspiration, the average lung density was (-879.51±32.82) HU, the density per unit volume was (0.12±0.03) g/cm3, while in expiratory they were (-688.14±62.38) HU and (0.31±0.06) g/cm3. Conclusion MSCT pulmonary function tests with the analysis software of computer-aided inspection system have good correlation with PFT.
4.Quantitative assessment of pulmonary function using low dose multi-slice spiral CT in smoker
Huai CHEN ; Qingsi ZENG ; Jinping ZHENG ; Yubao GUAN ; Chaoliang ZHANG ; Renli CEN
Chinese Journal of Radiology 2012;46(5):405-409
ObjectiveTo evaluate the clinical feasibility of low dose MSCT for quantitative assessment of pulmonary function in smokers.MethodsOne hundred and forty-six patients with chronic objective pulmonary disease ( COPD ) including 109 smokers ( 74.6% ) and 37 non-smokers ( 25.3% )underwent pulmonary function test and low-dose MSCT scan.All data were analyzed using computer-aided lung anlysis software.Pulmonary function parameters from low-dose MSCT were compared between smokers and non-smokers and also compared with pulmonary function test in non-smokers ( Pearson test).Results In smokers,the average volume at full inspiratory phase (Vin) was (5125 ± 862 ) ml,mean lung attenuation was ( - 902 ± 26 ) HU,mean lung density was (0.0984 ± 0.0260 ) g/cm3,emphysema volume was (2890 ±1370) ml.The average volume at full expiratory phase (Vex) was (2756 ±1027) ml,mean lung attenuation was ( -811 ±62) HU,mean lung density was (0.1878 ±0.0631 ) g/cm3,emphysema volume was (685 ±104) ml.In non-smokers,the average Vin was (3734 ± 759) ml,mean lung attenuation was ( -876 ±40) HU,mean lung density was (0.1244 ±0.0401 )g/cm3,emphysema volume was ( 1503 ± 1217) ml.The average Vex was ( 1770 ± 679 ) ml,mean lung attenuation was ( - 765 ± 56 ) HU,mean lung density was (0.2360 ± 0.0563 ) g/cm3,emphysema volume was ( 156 ± 45 ) ml.There were significant differences between smokers and non-smokers (P <0.01 ).The Vex/Vin was correlated with residual volume/total lung capacity ( RV/TLC,r =0.60,P<0.01 ),and Vin was correlated with TLC ( r =0.58,P < 0.01 ),Vex with RV ( r =0.59,P<0.01 ).Pixel index ( PI ) -950in was correlated with FEV 1% pre and FEV1/FVC% ( r =- 0.53,- 0.62,respective,P < 0.01 ),Pl-950ex was correlated with FEV1 % pre and FEV1/FVC% ( r =-0.71,-0.77,respective,P<0.0l).ConclusionLow-dose MSCT can be a potential imaging tool for quantitative pulmonary function assessment in smokes.
5.Application of Monte Carlo sampling method in iodized salt monitoring.
Chinese Journal of Epidemiology 2002;23(4):262-264
OBJECTIVETo explore a sampling method which could reflect iodine deficiency disorders (IDD) status at provincial level and discover risk areas with non-iodized salt problem.
METHODBaseline data of Iodized salt from Gansu and Fujian provinces were analyzed with Monte Carlo method both at county and prefecture levels respectively. True positive rate and false positive rate were also calculated.
RESULTSWith data from 7 - 8 villages or 4 - 5 townships counties at risk could be discovered. The true positive rate was around 80% and false positive rate was around 20%. At prefecture level, when randomly selecting and checking 3 counties, the samples would satisfy the discovery of all the risk areas with non-iodized salt problem.
CONCLUSIONSWe suggested that the sampling method of iodized salt investigation in national IDD surveillance as follows: to randomly choose 3 counties at each prefecture, 4 townships at each county, 2 villages at each township and 10 salt samples by household survey. The coverage rate of iodized salt in a province could be calculated by post-weighted method with population number.
China ; Drug Monitoring ; methods ; Humans ; Iodine ; deficiency ; pharmacology ; Monte Carlo Method ; Sodium Chloride, Dietary ; pharmacology
6.Study on the neonate umbilical cord blood thyroid stimulating hormone level in the universal iodized salt areas and its application.
Chinese Journal of Epidemiology 2002;23(4):250-253
OBJECTIVETo investigate the neonatal umbilical cord blood thyroid stimulating hormone (TSH) level in the universal iodized salt areas and put forward the cut-point, then analyze its application.
METHODSSeven provinces were selected where the pregnant women having satisfied urinary iodine levels, then the urinary samples of pregnant women and the neonates cord blood were collected for urine iodine and TSH tests, and the relative factors were also recorded.
RESULTSTotal 1 524 urine and cord blood samples were collected from pregnant women and their new borns respectively. The median urinary iodine of pregnant women was 246.0 micro g/L, and the median TSH was 3.58 mU/L. The TSH level among seven areas and the neonatal delivery type varied significantly.
CONCLUSIONSThe neonatal cord blood TSH was influenced by several factors and could not be controlled, thus not be suitable as a iodine deficiency disorders surveillance indicator.
Delivery, Obstetric ; Female ; Fetal Blood ; drug effects ; metabolism ; Humans ; Iodine ; pharmacology ; urine ; Pregnancy ; Thyrotropin ; blood