1.The model of mouse lung tumor short-term induction test for assaying the carcinogencity induced by extracts of birch wood dust.
Peng HE ; Desheng WU ; Qinan DONG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2002;20(2):116-118
OBJECTIVETo assay the carcinogencity of water and organic extracts of birch wood dust.
METHODSOne stage and two stage model of mouse lung tumor by short-term induction test were used.
RESULTSIn the one stage experiment, no significant difference of the incidence of mice lung tumors was observed between different dosage groups of water extracts and organic extracts. In the two stage experiment, the tumor incidence and the average number of tumor per mouse in three dosage groups treated with the water extracts(1, 2, 4 g/kg) were 4.08% and 0.04, 8.33% and 0.15, 14.30% and 0.24 respectively with dose increment. There was a significant dose-response relationship between them(P < 0.05), and the tumor incidence and the average number of tumor per mouse in 4 g/kg group were significantly higher than those in the control group and 1 g/kg group and its one stage group(P < 0.05). The tumor incidence and the average number of tumor per mouse induced by organic extracts were higher with increasing dose, but no significant difference among groups was found (P > 0.05).
CONCLUSIONBoth extracts of birch wood dust may be initiators, and carcinogenic effect of the water extract is stronger than that of the organic extract.
Animals ; Betula ; Disease Models, Animal ; Dust ; Lung Neoplasms ; etiology ; Mice ; Plant Extracts ; toxicity ; Wood
2.Simultaneous Determination of 9 Components in Huoxiang Zhengqi Oral Liquid by HPLC
Jinfeng CHEN ; Dale GUO ; Ziliang DONG ; Qinan YU ; Tao PENG ; Zhangyu LI ; Jiawen YU ; Qing LU ; Chen YAO ; Yun DENG ; Shaorong QIN
China Pharmacy 2019;30(21):2957-2962
OBJECTIVE: To establish a method for simultaneous determination of nine components in Huoxiang zhengqi oral liquid, and to improve and perfect the quality standard of Huoxiang zhengqi oral liquid. METHODS: The contents of nine components in 10 batches of Huoxiang zhengqi oral liquid were determined by HPLC, such as licorice coumarin, isorlicin, liquiritinapioside, narirutin, liquiritin, saponins, hesperidin, magnolol and honokiol. The determination was performed on Kromasil Eternity XT-5-C18 column with mobile phase consisted of acetonitrile-0.05% phosphoric acid solution (gradient elution) at the flow rate of 1 mL/min. The detection wavelength was set at 220 nm, and column temperature was 25 ℃. The sample size was 10 μL. RESULTS: The linear range of licorice coumarin, isorlicin, liquiritinapioside, narirutin, liquiritin, saponins, hesperidin, magnolol and honokiolin were 0.000 5-0.007 5, 0.000 8-0.025 0, 0.006 1-0.976 0, 0.001 6-0.250 0, 0.007 8-0.025 0, 0.000 4- 0.062 7, 0.008 6-0.276 0, 0.010 0-0.500 0, 0.010 0-0.500 0 mg/mL (r=0.999 2-1.000 0). The detection limits were 0.001 3, 0.000 1, 0.004 7, 0.005 0, 0.012 0, 0.001 3, 0.007 8, 0.007 7 0, 0.005 8 μg/mL, and the quantitative limits were 0.013 0, 0.000 8, 0.047 0, 0.050 0, 0.120 0, 0.013 0, 0.078 0, 0.070 0, 0.058 0 μg/mL, respectively; RSD of precision, stability and repeatability tests were less than 3.0% (n=6). Average recovery rates were 98.67%, 101.85%, 98.97%, 103.05%, 100.00%, 97.78%, 97.91%, 100.13%, 101.95%; RSDs were 1.14%, 2.18%, 0.40%, 0.17%, 1.38%, 0.85%, 1.38%, 0.10%, 1.35% (n=6). CONCLUSIONS: The established method is accurate and reliable, which can provide reference for the establishment of the overall quality control evaluation system and the improvement of quality standard for Huoxiang zhengqi oral liquid.