1.Development and Initial Validation of the Multi-Dimensional Attention Rating Scale in Highly Educated Adults.
Xin-Yang ZHANG ; Karen SPRUYT ; Jia-Yue SI ; Lin-Lin ZHANG ; Ting-Ting WU ; Yan-Nan LIU ; Di-Ga GAN ; Yu-Xin HU ; Si-Yu LIU ; Teng GAO ; Yi ZHONG ; Yao GE ; Zhe LI ; Zi-Yan LIN ; Yan-Ping BAO ; Xue-Qin WANG ; Yu-Feng WANG ; Lin LU
Chinese Medical Sciences Journal 2025;40(2):100-110
OBJECTIVES:
To report the development, validation, and findings of the Multi-dimensional Attention Rating Scale (MARS), a self-report tool crafted to evaluate six-dimension attention levels.
METHODS:
The MARS was developed based on Classical Test Theory (CTT). Totally 202 highly educated healthy adult participants were recruited for reliability and validity tests. Reliability was measured using Cronbach's alpha and test-retest reliability. Structural validity was explored using principal component analysis. Criterion validity was analyzed by correlating MARS scores with the Toronto Hospital Alertness Test (THAT), the Attentional Control Scale (ACS), and the Attention Network Test (ANT).
RESULTS:
The MARS comprises 12 items spanning six distinct dimensions of attention: focused attention, sustained attention, shifting attention, selective attention, divided attention, and response inhibition.As assessed by six experts, the content validation index (CVI) was 0.95, the Cronbach's alpha for the MARS was 0.78, and the test-retest reliability was 0.81. Four factors were identified (cumulative variance contribution rate 68.79%). The total score of MARS was correlated positively with THAT (r = 0.60, P < 0.01) and ACS (r = 0.78, P < 0.01) and negatively with ANT's reaction time for alerting (r = -0.31, P = 0.049).
CONCLUSIONS
The MARS can reliably and validly assess six-dimension attention levels in real-world settings and is expected to be a new tool for assessing multi-dimensional attention impairments in different mental disorders.
Humans
;
Adult
;
Male
;
Attention/physiology*
;
Female
;
Middle Aged
;
Reproducibility of Results
;
Young Adult
;
Psychometrics
2.Prognostic Significance of Endothelial Activation and Stress Index in Mantle Cell Lymphoma.
Xin-Yue ZHOU ; Zhi-Qin YANG ; Jin HU ; Feng-Yi LU ; Qian-Nan HAN ; Huan-Huan ZHAO ; Wen-Xia GAO ; Yu-Han MA ; Hu-Jun LI ; Zhen-Yu LI ; Kai-Lin XU ; Wei CHEN
Journal of Experimental Hematology 2025;33(4):1051-1056
OBJECTIVE:
To investigate the predictive value of endothelial activation and stress index (EASIX) for the prognosis of patients with mantle cell lymphoma (MCL).
METHODS:
A retrospective analysis was conducted to assess prognosis and compare the clinical features of patients diagnosed with MCL who were admitted to the Affiliated Hospital of Xuzhou Medical University from January 2010 to June 2023, had therapeutic indications and received standard treatment.
RESULTS:
A total of 66 patients were included and divided into high EASIX group and low EASIX group, according to a cutoff value of 0.97 determined by the receiver operating characteristic (ROC) curve. Multivariate Cox regression analysis showed that prealbumin <0.2 g/L, high EASIX, and ECOG PS score ≥2 were independent risk factors influencing overall survival (OS) in MCL patients. The median OS of patients in the high and low EASIX group was 13.0 and 37.5 months, and the median progression-free survival was 8.8 and 26.0 months, respectively. The proportions of patients with ECOG PS score ≥2 and prealbumin <0.2 g/L at onset significantly increased in the high EASIX group compared to those in the low EASIX group.
CONCLUSION
At the time of initial diagnosis, EASIX can serve as an independent prognostic indicator impacting OS in patients with MCL. Furthermore, patients in the high EASIX group experience a poorer prognosis and shorter survival duration compared with those in the low EASIX group.
Humans
;
Lymphoma, Mantle-Cell/pathology*
;
Prognosis
;
Retrospective Studies
;
Male
;
Female
;
Middle Aged
;
Aged
;
ROC Curve
3.Association of angiotensin Ⅱ type 1 receptor autoantibody and sperm motility in human semen.
Dao-Qin TU ; Yu-Huan YANG ; Gui-Fang YANG ; Yi-Nan ZHANG ; Yao CHEN ; Xue-Ming LI ; Yu-Hui SHI ; Xiao-Li YANG ; Feng WANG
National Journal of Andrology 2025;31(5):387-394
OBJECTIVE:
To investigate the relationship between angiotensin Ⅱ type 1 receptor autoantibody (AT1-AA) and semen parameters. Methods: The semen samples of 820 male patients who were treated in the Reproductive Medicine Center of Taiyuan Central Hospital from August 2022 to August 2023 were retrospectively analyzed. The levels of AT1-AA and Ang Ⅱ of semen were detected by ELISA, and the function of AT1-AA was detected by cardiomyocyte beating assay in suckling rats. The patients were divided into low group, median group and high group according to the OD values of AT1-AA. The differences in general data and semen parameters between different groups were analyzed. And the correlation between AT1-AA level and semen parameters in semen of all study subjects was analyzed by the method of Spearman analysis. And the relationships between AT1-AA OD value, Ang Ⅱ level and semen parameters in the AT1-AA high value group were analyzed as well.
RESULTS:
AT1-AA was present in semen with good function. There was no significant difference in the general data of patients in different AT1-AA levels (P>0.05). In the comparison of semen parameters among the groups with different levels of AT1-AA, there were differences in sperm concentration, PR concentration, NP%, and ALH among the three groups (P<0.05). And AT1-AA OD value was positively correlated with total sperm count, sperm concentration, PR concentration, and NP%, and negatively correlated with semen volume (P<0.05). In the AT1-AA high value group, the OD value of AT1-AA in semen was negatively correlated with inactive sperm, and positively correlated with total motility ([PR+NP]%), curve rate, mean path rate, and ALH. However, there was no correlation between the level of Ang Ⅱ in semen and semen parameters (P>0.05).
CONCLUSION
The presence of AT1-AA in semen may be associated with the promotion of sperm motility.
Male
;
Humans
;
Autoantibodies
;
Sperm Motility
;
Semen
;
Retrospective Studies
;
Receptor, Angiotensin, Type 1/immunology*
;
Animals
;
Rats
;
Angiotensin II
;
Adult
;
Sperm Count
;
Semen Analysis
;
Receptor, Angiotensin, Type 2/immunology*
4.Analysis of Animal Models of Hepatic Ascites Based on Clinical Evidence Characteristics of Traditional Chinese and Western Medicine
Yu HUAN ; Shilei QIN ; Shumei JI ; Shuo NAN ; Yilong HU ; Ting ZUO ; Mingsan MIAO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(15):200-205
Hepatic ascites is one of the common and difficult complications in the decompensated stage of liver cirrhosis, and its incidence is increasing. In clinical practice, the prognosis of patients with hepatic ascites after surgery is worse, and the disease is recurrent. Traditional Chinese medicine (TCM) has certain advantages in treating hepatic ascites. However, there is no uniform standard for the preparation of animal models of hepatic ascites in accordance with TCM evidence. Therefore, this paper summarized the literature on animal models of hepatic ascites and analyzed the existing animal models of hepatic ascites based on the clinical diagnostic criteria of hepatic ascites in TCM and western medicine. The results show that the commonly used modeling methods for hepatic ascites mainly include the single-factor method, composite factor induction method, surgical method, and immunization method. Most of them are guided by western medicine theories, and their pathogenic mechanisms are mostly consistent with those of western medicine and are different from TCM evidence. Therefore, it is suggested that TCM intervening factors should be imposed in the process of model preparation, so as to prepare an animal model of hepatic ascites that meets the clinical evidence characteristics of TCM and western medicine.
5.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
6.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
7.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
8.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
9.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.
10.Clinical Analysis of Neonates with Umbilical Cord Wrapped Around the Neck for 4 or More Loops
Xizi WU ; Guo AI ; Nan YU ; Yihong YANG ; Qin ZHOU
Journal of Practical Obstetrics and Gynecology 2024;40(9):723-728
Objective:To investigate the high risk factors,diagnostic accuracy of ultrasonography and pregnan-cy outcomes of umbilical cord wrapped around the neck for≥4 loops.Methods:The clinical data of 64 pregnant women with umbilical cord around the neck for≥4 loops(the group with umbilical cord around the neck≥4 loops)in Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology from January 2011 to February 2024 were retrospectively analyzed.At the same time,80 cases with umbilical cord around the neck for 1-2 loops(the group with umbilical cord around the neck 1-2 loops)were randomly selected as the controls.General information,clinical manifestations,ultrasound diagnosis and other data of the two groups were collected.The risk factors of umbilical cord around the neck≥4 loops and diagnostic accuracy of ultrasonography were ana-lyzed with univariate and multivariate Logistic regression analysis,and the pregnancy outcomes were compared between the two groups.Results:①The incidence of pregnancy,abortion,delivery and history of cesarean sec-tion were lower in the group with umbilical cord around the neck ≥4 loops than those in the group with umbilical cord around the neck 1-2 loops.The incidence of consciously abnormal fetal movement,abnormal umbilical ar-tery systolic/diastolic(S/D)ratio,abnormal fetal heart rate monitoring(NST)and fetal distress were higher in the group with umbilical cord around the neck≥4 loops than those in the group with umbilical cord around the neck 1-2 loops,and the differences were statistically significant(P<0.05).②Multivariate Logistic regression analysis showed that polyhydramnios and excessively long cord were independent risk factors for umbilical cord around the neck≥4 loops(OR>1,P<0.05).③When the time between ultrasound diagnosis and the operation was 2 days,the consistency rate between ultrasound diagnosis of umbilical cord around the neck≥4 loops and intrao-perative diagnosis was the highest,and the difference was statistically significant with>3 days(46.2%vs.6.30%,P<0.05).Compared with umbilical cord around the neck 3 loops,ultrasound diagnosis of umbilical cord loops around the neck at 4 or 5 loops had a higher consistency rate with intraoperative diagnosis,and the differ-ence was statistically significant(P<0.05).④The incidence of premature delivery,neonatal asphyxia and admis-sion to neonatology in the group with umbilical cord around the neck ≥4 loops were higher than those in the group with umbilical cord around the neck 1-2 loops,and the difference was statistically significant(P<0.05);and the gestational week and birth weight of newborns were significantly lower(P<0.05).Conclusions:Polyhydramnios and excessively long cord are high risk factors for umbilical cord around the neck≥4 loops.The closer the ultra-sound diagnosis is to the time before cesarean section and the more times the umbilical cord is around the neck in ultrasonic diagnosis,the higher the diagnostic accuracy.Fetal outcomes with umbilical cord around the neck≥4 loops are worse.

Result Analysis
Print
Save
E-mail