1.Factor Analysis of Nurses Observation Scale for Inpatinent Evalu ation
Feifei LI ; Philips MICHAEL ; Zhongfu JI ; Qiling WU ; Jing WAN
Chinese Journal of Clinical Psychology 2001;9(1):17-20
Objective: To improve clinical utility of the Nurses Observation Sca le for Inpatient Evaluation (NOSIE-30) in China. Methods: Based on the original scale, which only provides names and ranked scores for items, we developed clear definitions for each item and anchoring descriptions for score rating. 164 firs t-episode schizophrenic patients were evaluated with this scale every two weeks after admission. A total of 994 evaluations were completed. The collected data w ere randomly divided into two independent data sets. The number and content of t he subscales were revised based on principal component factor analysis and item analysis of the first data set. The revised scale was then evaluated and compare d with the original 7-subscale version of the instrument using the second data s et. Results: Factor analysis found that the factor structu re of the revised scal e was markedly different from that of the original instrument. Item analysis res ulted in elimination of 30 original items and redistribution of the remaining 26 items into 5 subscales. Comparison of the revised scale with the original instr ument revealed better psychometric properties for the former than the latter.Conclusion: The subscale scores of the original 7-subscale v ersion of NOSIE-30 did not reflect independent symptom clusters in Chinese schizophrenic inpatients. T o improve the usefulness of the scale in China, the present study recommended a better revised scale with re-definition of items into 5 subscales.
2.Clinical and imaging characteristics of bilateral medial medullary infarction in elderly patients
Xuemei WANG ; Yanling WANG ; Yijie SHI ; Hongpeng ZHANG ; Qiling JI ; Xiaokun GENG ; Huishan DU
Chinese Journal of Geriatrics 2019;38(3):255-259
Objective To investigate the clinical features of bilateral medial medullary infarction (BMMI)in elderly patients.Methods Clinical and imaging data of 8 elderly BMMI patients with different morphology on diffusion-weighted magnetic resonance imaging (DWI-MR) were retrospectively analyzed.All patients were diagnosed by MRI,while 4 patients received CTA and vascular ultrasound testing,and the other 4 patients received vascular ultrasound testing.Results All 8 cases(100.0%) had acute-onset BMMI.Patients showed varying degrees of acroparalysis(7/8,87.5 %),dizziness (5/8,62.5 %),dysarthria(6/8,80.0 %),dysphagia(3/8,37.5 %),deep or superficial sensory dysfunction(5/8,62.5 %),consciousness disorders (2/8,25.0 %),dyspnea (2/8,25.0 %),and tinnitus(1/8,12.5 %).Lesions in most patients were located in the upper part of medulla oblongata(7/8,87.5 %).In the transverse direction of DWI,the lesions as the inverted V shape were seen in 3 cases (37.5%),the V shape(12.5%)in 1 case,the Y shape(37.5%)in 3 cases,and the heart shape(12.5%) in 1 case.All 8 patients were complicated with posterior cerebral artery stenosis or occlusion,of whom patients with heart-or Y-shaped lesions showed progressive exacerbation.After treatment,4 cases (50.0 %) recovered,3 cases (37.5 %) improved,and 1 case (12.5 %) unrecovered before discharge from the hospital.Conclusions Most elderly BMMI patients have concurrent posterior circulation artery stenosis,and patients with heart-or Y-shaped lesions on MR-DWI show rapid progression and have a poor prognosis.Cranial examination with MR-DWI is helpful for early clinical diagnosis of BMMI,prediction of disease progression and effective prevention of complications.
3.Application of 5-point positioning point-contact pedicle navigation template in the case of scoliosis and complex pedicle
Lihang WANG ; Tingsheng LU ; Qiling CHEN ; Shudan YAO ; Xingwei PU ; Linsong JI ; Guoquan ZHAO ; Beiping OUYANG ; Bin ZHANG ; Zaisong YANG ; Chunshan LUO
Chinese Journal of Tissue Engineering Research 2024;28(18):2859-2864
BACKGROUND:The pedicle navigation template has many advantages,but there are still some problems.For example,poor soft tissue dissection leads to poor adhesion of the pedicle navigation template,resulting in screw path deviation;careful dissection of soft tissue to fit the pedicle navigation template leads to prolonged surgery time and increased bleeding;the design of the pedicle navigation template cannot predict the vertebral rotation and the impact of body position changes,resulting in the poor fitting. OBJECTIVE:To explore the utility of a new 5-point positioning point-contact pedicle navigation template in the case of scoliosis and complex pedicle. METHODS:A total of 20 patients with scoliosis and complicated pedicle admitted to the Department of Spinal Surgery,Guizhou Hospital,Beijing Jishuitan Hospital from February 2020 to February 2023 were selected for scoliosis orthopedics.During the operation,the 5-point positioning point-contact pedicle navigation template was used to guide the screws.According to the inclusion and exclusion criteria,34 cases were matched as the empirical nail placement group,and conventional barehanded nail placement was performed.The time of placement,the amount of bleeding,the number of fluoroscopies,the number of manual diversions,the level and accuracy of pedicle screws,the complications of placement,and the rate of correction of main curvature were compared between the two groups. RESULTS AND CONCLUSION:(1)There were no significant differences in sex,age,coronal Cobb's angle of the main curvature,bending Cobb's angle of the main curvature,pedicle variation,apex rotation,fusion segment,number of screws,level of screws,accuracy of screws,and rate of correction of main curvature between the navigation template group and the empirical nail placement group(P>0.05).(2)Compared with the empirical nail placement group,the navigation template group had more advantages in time of placement(P=0.034),amount of bleeding(P=0.036),number of fluoroscopies(P=0.000)and number of manual diversions(P=0.021).(3)There were 0 cases of screw-related complications in both groups.(4)In conclusion,the 5-point positioning point-contact 3D printing pedicle navigation template has a claw-like structure.It can firmly adapt to various deformities of the lamina articular process,avoid drift,and accurately place the screws.It has a point-like contact lamina structure to avoid extensive and complete dissection of the posterior structure,and reduce bleeding,operation time,and trauma.Pre-designed screw entry points and directions can reduce the number of fluoroscopy and operation time.Segmental design can avoid discomfort due to changes in anesthesia position.The operation is simple and the accuracy of screw placement is high.
4.Application of a new point contact pedicle navigation template as an auxiliary screw implant in scoliosis correction surgery.
Lihang WANG ; Qian TANG ; Qiling CHEN ; Tingsheng LU ; Shudan YAO ; Xingwei PU ; Linsong JI ; Chunshan LUO
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(6):700-705
OBJECTIVE:
To explore the effectiveness of a new point contact pedicle navigation template (referred to as "new navigation template" for simplicity) in assisting screw implantation in scoliosis correction surgery.
METHODS:
Twenty-five patients with scoliosis, who met the selection criteria between February 2020 and February 2023, were selected as the trial group. During the scoliosis correction surgery, the three-dimensional printed new navigation template was used to assist in screw implantation. Fifty patients who had undergone screw implantation with traditional free-hand implantation technique between February 2019 and February 2023 were matched according to the inclusion and exclusion criteria as the control group. There was no significant difference between the two groups ( P>0.05) in terms of gender, age, disease duration, Cobb angle on the coronal plane of the main curve, Cobb angle at the Bending position of the main curve, the position of the apical vertebrae of the main curve, and the number of vertebrae with the pedicle diameter lower than 50%/75% of the national average, and the number of patients whose apical vertebrae rotation exceeded 40°. The number of fused vertebrae, the number of pedicle screws, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were compared between the two groups. The occurrence of implant complications was observed. Based on the X-ray films at 2 weeks after operation, the pedicle screw grading was recorded, the accuracy of the implant and the main curvature correction rate were calculated.
RESULTS:
Both groups successfully completed the surgeries. Among them, the trial group implanted 267 screws and fused 177 vertebrae; the control group implanted 523 screws and fused 358 vertebrae. There was no significant difference between the two groups ( P>0.05) in terms of the number of fused vertebrae, the number of pedicle screws, the pedicle screw grading and accuracy, and the main curvature correction rate. However, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were significantly lower in trial group than in control group ( P<0.05). There was no complications related to screws implantation during or after operation in the two groups.
CONCLUSION
The new navigation template is suitable for all kinds of deformed vertebral lamina and articular process, which not only improves the accuracy of screw implantation, but also reduces the difficulty of operation, shortens the operation time, and reduces intraoperative bleeding.
Humans
;
Orthopedic Procedures
;
Pedicle Screws
;
Retrospective Studies
;
Scoliosis/surgery*
;
Spinal Fusion/methods*
;
Spine
;
Surgery, Computer-Assisted/methods*