1.The development and transplantation of LCD module-based interface for medical diagnosis instrument.
Huisheng ZHANG ; Xinyu LIU ; Qiaoliang LI ; Jie RAO ; Xiaofei ZHANG ; Xiaoxuan WANG ; Shumei LIN ; Li YIN ; Siping CHEN ; Tianfu WANG
Chinese Journal of Medical Instrumentation 2012;36(6):400-406
Based on LCD Module and Visual C++ development environment, this paper proposes a new method which can quickly develop the human-machine interface .We define a LCD module programming interface by designing Serial Communication Class(SCS). On this basis,we achieve the transplantation on an Embedded ARM Platform to fulfil the requirements of Medical Diagnostic Instruments (MDI). Experimental results show that this method has advantages of short development cycle and high level transplantation which has broad application prospects in the field of Medical Diagnosis Instrument.
Diagnosis, Computer-Assisted
;
instrumentation
;
Equipment Design
;
Liquid Crystals
;
Robotics
;
instrumentation
;
methods
;
Software
;
User-Computer Interface
2.Predictive value of non-enhanced CT combined with clinical indicators in severe acute pancreatitis
Qiaoliang CHEN ; Dandan XU ; Junjie YANG ; Weisen YANG ; Yan GU ; Yeqing WANG ; Guohua FAN ; Guojian YIN ; Liang XU
Chinese Journal of Emergency Medicine 2023;32(10):1333-1339
Objective:To establish and validate a nomogram model for early prediction of the risk of acute pancreatitis (AP) progressing to severe acute pancreatitis (SAP).Methods:CT signs and clinical laboratory parameters of 361 AP patients admitted to our Hospital from January 2016 to July 2022 were retrospectively collected. There were 221 males (61.2%) and 140 females (38.8%). According to the Atlantic score, all patients were divided into the SAP group (64 cases) and the non-SAP (NSAP) group (297 cases). Univariate analysis was used to screen out variables with statistically significant differences. Multivariate Logistic regression analysis was used to screen out the independent risk factors of SAP, and finally a nomogram prediction model was established. Receiver operating characteristic (ROC) curve, calibration curve and decision curve (DCA) were used to evaluate the predictive efficacy, accuracy and clinical practicability of the model, and Bootstrap method was used to verify the model internally.Results:Univariate analysis and multivariate Logistic regression analysis showed that pleural effusion ( OR=7.353, 95% CI: 3.344-16.170), posterior pararenal space (PPS) involvement ( OR=3.149, 95% CI: 1.314-7.527), serum creatinine concentration (Cr) ( OR=1.027, 95% CI: 1.017-1.038) and serum calcium concentration (Ca 2+) ( OR=0.038, 95% CI: 0.009-0.166) were independent risk factors for SAP ( P<0.05). A Nomogram model was established based on these four factors. The area under the ROC curve (AUC) of this model was 0.905 (95% CI: 0.869-0.933), indicating high predictive efficiency. Internal verification showed that the model had good accuracy in predicting SAP, and C-index was 0.90. DCA analysis showed that the model had high clinical practicability. Conclusions:The Nomogram model combining pleural effusion, PPS involvement, Cr and Ca 2+ had a good effect on early prediction of SAP, which could provide a new reference tool for clinical diagnosis and treatment.
3.Design of acoustic radiation force module for ultrasound elastography.
Mingbo QIU ; Qiaoliang LI ; Xin CHEN ; Wanguan YI ; Hu TANG ; Xinru ZHANG ; Siping CHEN ; Tianfu WANG
Chinese Journal of Medical Instrumentation 2013;37(5):322-326
Developing an acoustic radiation force excitation module including 64 channels based in FPGA for ultrasound elastography. The circuit of the module was derived in bipolar, and the parameters such as excitation frequency, pulse repetition frequency, pulse number, element number and focus depth were adjustable. The acoustic field for special parameter was experimented with OptiSon laser acoustic field system with a result which reflects the width of focal spot is about 3 mm. The acoustic power was experimented with RFB2000 radiation force balance with a result which reflects acoustic power is increasing linearly with the number of pulses and the number of elements, and is increasing squarely with the peak-to-peak value of excitation voltage. The module is promising in factual application which can be triggered externally in synchronously, and can be combined with B-mode ultrasound system for ultrasound elastography.
Acoustics
;
Elasticity Imaging Techniques
;
Ultrasonics
4. Years of potential life lost due to premature death of cardiovascular diseases among residents in Suzhou from 1987 to 2017
Chunyan HUANG ; Jianxin LI ; Shufeng CHEN ; Jichun CHEN ; Yan LU ; Qiaoliang HUANG ; Linchi WANG ; Yujie HUA ; Yihe HU
Chinese Journal of Preventive Medicine 2020;54(1):104-107
From 1987 to 2017, cardiovascular disease (CVD) had been ranking the first cause of death in Suzhou, and the mortality rate showed an upward trend annual percentage changes (APC=0.62%,