1.Significance of E-cadherin/catenin adhesion complex expression in nasopharyngeal carcinoma
Qiang WEI ; Minyi WEI ; Xiujiu LIANG ; Hua LI ; Jingyan LU
Basic & Clinical Medicine 2006;0(07):-
Objective To elucidate the expression pattern of E-cadherin/catenin adhesion complex and its association with pathologic features in nasopharyngeal carcinoma(NPC).Methods Fifty-two non-keratinizing NPC specimens with adjacent non-neoplastic mucosa were examined for E-cadherin,?-CATenin,?-CATenin.Results Abnormal expression rate of E-cadherin,?-catenin and ?-catenin in NPCs were 48.1%(25/52),32.7%(17/52) and 34.6%(18/52),respectively,whereas all adjacent non-neoplastic tissues normally expressed these proteins.Difference of expression of E-cadherin,?-catenin and ?-catenin between tumor tissues and non-cancerous tissues was statistically significant(P
3.Comparison of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer
Wei, QIU ; Yanjun, HUA ; Zequan, XU ; Qiang, WU
Chinese Journal of Experimental Ophthalmology 2017;35(6):544-547
Background The measurement of corneal Q value is essential for corneal refractive surgery and calculation of intraocular lens during cataract surgery.Topolyzer was often used for the measurement of Q value,and recently Topcon KR-1W and iTrace were applied in ophthalmology.However,whether the measured values are interchangeable is unclear.Objective This study was to assess the difference and consistency of corneal Q values measured by Topcon KR-1W,iTrace and Topolyzer.Methods Corneal Q values were measured on 100 right eyes of 100 healthy subjects under the approval of Ethic Committee of the Sixth Hospital Affiliated to Shanghai Jiaotong University and informed consent of each subject from November to December in 2014 with Topcon KR-1W,iTrace and Topolyzer.Three valid measurements were obtained for each device,and the average values from each device were calculated.The difference of the outcomes among the instruments was compared by repeated measures analysis of variance (ANOVA),and the consistency among the outcomes from different apparatus was analyzed by Bland-Altman plots.Results The mean corneal Q values were-0.184-±0.112,-0.117±0.167 and-0.269±0.117 from Topcon KR-1W,iTrace and Topolyzer,respectively,with a significant difference among them (P < 0.001).The measured Q value by Topcon KR-1W was 0.085±0.010 larger than that by Topolyzer,and the Q values by iTrace was 0.152± 0.014 larger than that by Topolyzer,while the Q values obtained by Topcon KR-1W was 0.067±0.016 smaller than that by iTrace (all at P<0.05).The 95% confidence interval of the values between Topcon KR-1W and iTrace,Topcon KR-1W and Topolyzer,iTrace and Topolyzer were-0.106 to-0.028,0.060 to 0.109 and 0.118 to 0.186,respectively.Bland-Altman plots showed that 6%,6% and 5% values were outside of 95% agreement of limit (LoA) between Topcon KR-1W and iTrace,iTrace and Topolyzer or KR-1W and Topolyzer,respectively,with the maximal differences of 0.28,0.43 and 0.38.Conclusions Corneal Q values measured by Topcon KR-1W and iTrace are larger than those measured by Topolyzer.Due to the poor agreements among the corneal Q values by the 3 kinds of devices,they are not interchangeable in clinical applications for the measurement of corneal Q value.
4.Clinical application of percutaneous vertebroplasty
Zhentang WANG ; Lin LIN ; Qiang HAO ; Wei CHEN ; Hua YE ;
Chinese Journal of Radiology 2000;0(12):-
Objective To evaluate the efficacy of percutaneous vertebroplasty for treating the vertebral compression fractures and vertebral metastatic neoplasms, and to assess its clinical curative effects Methods Among 81 cases (47 men and 34 women; ages 35~84, mean age 61 2 years), 110 vertebrae with metastatic neoplasms (61 cases) or vertebral osteoporosis (20 cases) were infused with methacrylate guided by DSA Effect of the operations was observed closely after the procedures Results The procedures were successful in all the involved patients and no significant complications were noted clinically Among the 61 patients treated for malignancies, 58 showed marked pain relief and 3 moderate pain relief 20 patients with vertebral osteoporosis demonstrated complete pain relief The cement leakage observed on radiographs included slight leakage to the adjacent disc (6 of 110, 5 5%), the epidural fat (8 of 110, 7 3%), the perivertebral venous plexus (2 of 110, 1 8%), and the paravertebral soft tissues (2 of 110, 1 8%) Conclusion Percutaneous vertebroplasty can significantly relieve the pain in patients with osteoporotic fractures caused by the malignancies and the vertebral osteoporosis We suggest that slight PMM leaks, when not symptomatic, should not be considered as complications
5.Research on ursolic acid production of Eriobotrya japonica cell suspension culture in WAVE bioreactor.
Hui-hua LI ; De-heng YAO ; Jian XU ; Wei WANG ; Qiang CHANG ; Ming-hua SU
China Journal of Chinese Materia Medica 2015;40(9):1693-1698
Through scale-up cultivation of Eriobotrya japonica suspension cells using WAVE bioreactor, the cell growth and ursolic acid (UA) accumulation were studied. The comparison test was carried out in the flask and the reactor with cell dry weight (DW) and UA content as evaluation indexes. The culture medium, DW and UA content were compared in 1 L and 5 L working volumes of bioreactor. The orthogonal test with main actors of inoculation amount, speed and angle of rotation was developed to find the optimal combination, in 1 L working volume of bioreactor. DW of the cell growth and the UA content in bioreactor were higher than those of the shaker by 105.5% and 27.65% respectively. In bioreactor, the dynamic changes of elements in the fluid culture, the dry weight of the cell growth and the UA content in 1 L and 5 L working volumes were similar. Inoculation of 80 g, rotational speed of 26 r · min(-1), and angle of 6 ° was the optimal combination, and the cell biomass of 19.01 g · L(-1) and the UA content of 27.750 mg · g(-1) were achieved after 100 h cultivation in 1 L working volume of bioreactor. WAVE Bioreactor is more suitable than flasks for the E. japonica cell suspension culture, and culture parameters can be achieved from 1 L to 5 L amplification.
Biomass
;
Bioreactors
;
Cell Culture Techniques
;
instrumentation
;
methods
;
Culture Media
;
chemistry
;
metabolism
;
Eriobotrya
;
chemistry
;
growth & development
;
metabolism
;
Triterpenes
;
analysis
;
metabolism
6.Intravascular large B-cell lymphoma: report of a case.
Guo-hua YU ; Gui-mei QU ; Wei-dong YAO ; Zhi-qiang LANG ; Wei WANG
Chinese Journal of Pathology 2009;38(7):488-489
Antigens, CD20
;
metabolism
;
Antigens, CD34
;
metabolism
;
Antineoplastic Combined Chemotherapy Protocols
;
therapeutic use
;
Cyclophosphamide
;
therapeutic use
;
Diagnosis, Differential
;
Doxorubicin
;
therapeutic use
;
Humans
;
Lymphoma, Large B-Cell, Diffuse
;
drug therapy
;
metabolism
;
pathology
;
Male
;
Melanoma
;
metabolism
;
pathology
;
Middle Aged
;
Prednisone
;
therapeutic use
;
Vascular Neoplasms
;
drug therapy
;
metabolism
;
pathology
;
Vincristine
;
therapeutic use
7.Changes of serum nerve growth factor level in n-hexane induced neuropathy.
Qiang LIU ; Yan-shu ZHANG ; Qing-jun LIU ; Hua-wei DUAN ; Tao YU ; Wei-wei LIU ; Chao-qiang JIANG ; Feng-sheng HE ; Yu-xin ZHENG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2005;23(3):220-221
Adolescent
;
Adult
;
Female
;
Hexanes
;
poisoning
;
Humans
;
Male
;
Nerve Growth Factor
;
blood
;
Occupational Diseases
;
blood
;
Peripheral Nervous System Diseases
;
blood
;
chemically induced
8.The effect of low intensity laser irradiation on the expression of transforming growth factor-β1 and interleukin-1β in scalded dermal tissues
Qiang DUAN ; Bingshui WANG ; Shouqin SHAN ; Xiang MU ; Hua YUAN ; Wei LIU
Chinese Journal of Physical Medicine and Rehabilitation 2015;37(3):176-178
Objective To study the effect of low intensity laser irradiation on wound healing and the expression of transforming growth factor beta-1 (TGF-β1) and interleukin beta-1 (IL-1β) in wounded tissue.Methods Steam was used to scald 60 BALB/c mice.They were then randomly divided into a laser group and a control group with 30 in each group.The wounds in the laser group were irradiated with a low-intensity He-Ne laser,while the control group was given the same treatment except that the instrument was turned off.The wound healing rate was calculated,and the full wound thickness was measured and a reverse transcription polymerase chain reaction (RT-PCR) was used to detect the expression of TGF-β1 and IL-1β right after the scalding and 1,3,7 and 14 days later.Results Seven and 14 days later,the wound healing rates in the laser group were (51.48 ± 5.89) % and (73.96 ± 7.25) %,respectively.Compared with the control group at the same time points,the difference was statistically significant.In the laser group the expression of TGF-β1 had increased significantly at days 1 and 3,then increased to a maximum at day 7.It was significantly greater than in the control group at all three of those time points.At day 14 the expression of TGF-β1 in the laser group was significantly lower than in the control group.The expression of IL-1 β in the laser group had decreased significantly at days 1 and 3,and gradually reduced to a minimum at day 7.It was significantly lower than in the control group at all three of those time points.Conclusion Low intensity He-Ne laser irradiation can accelerate wound healing after scalding,at least in mice.Its effect may be related to its regulation of the expression of IL-1 β and TGF-β1.
9.Expression and significance of aryl hydrocarbon receptor in atrial tissues of patients with atrial fibrillation
Jianming LEI ; Hua XIAO ; Qiang LI ; Xiao WEI ; Jingwen GUO ; Minghan XIAO
Chinese Journal of Pathophysiology 2017;33(5):826-831
AIM:To investigate the expression of aryl hydrocarbon receptor (AhR) in atrial tissues of the patients with rheumatic heart disease (RHD), and the effects of AhR on rheumatic atrial fibrosis.METHODS:Right atrial specimens obtained from the patients with RHD requiring valve replacement surgery were divided into chronic atrial fibrillation (RHD+cAF, n=11) group and sinus rhythm (RHD+sinus rhythm, n=25) group.The patients with congenital heart disease (CHD) and sinus rhythm (CHD+sinus rhythm, n=12) who underwent heart surgery served as controls.The collagen volume fraction in the atrial specimens was examined by Masson`s trichrome staining.The protein expression and distribution of AhR, AhR nuclear translocator (ARNT) and CYP1A1 were detected by the methods of immunohistochemistry and Western blot.The mRNA expression of AhR, ARNT and CYP1A1 was detected by real-time fluorescence quantitative PCR.RESULTS:Compared with CHD+sinus rhythm group, the collagen content and the expression of AhR, ARNT and CYP1A1 were significantly increased in RHD+sinus rhythm group and RHD+cAF group.Compared with RHD+sinus rhythm group, the collagen content and the expression of AhR, ARNT and CYP1A1 were significantly increased in RHD+cAF group (P<0.05).CONCLUSION:The expression of AhR is correlated with the degree of fibrosis.The expression of AhR/ARNT/CYP1A1 is increased in atrial tissues of patients with RHD, suggesting that AhR/ARNT/CYP1A1 should be involved in atrial fibrosis of the patient with RHD.
10.Simultaneous Determination of 16 Carcinogenic and Allergenous Dyestuffs in Toys by Ultra Performance Liquid Chromatography Tandem Mass Spectrometry
Qiang MA ; Hua BAI ; Chao WANG ; Qing ZHANG ; Wei MA ; Xin ZHOU ; Yiyang DONG ; Baolin WANG
Chinese Journal of Analytical Chemistry 2010;38(1):51-56
A comprehensive analytical method based on ultra performance liquid chromatography tandem mass spectrometry has been developed for the simultaneous determination of 16 carcinogenic and allergenous dye stuffs (acid red 26, basic red 9, disperse blue 1, acid violet 49, disperse blue 3, solvent yellow 1, dispersed blue 106, disperse orange 3, disperse yellow 3, basic violet 1, basic violet 3, disperse red 1, solvent yellow 3, disperse blue 124, solvent yellow 2 and disperse orange 37).Various toy samples, including textile, leath er, paper, wood, balloon, modeling clay, limitation tattoo and aqueous liquid, were extracted under ultrason ication.Qualitative and quantitative analysis was carried out for the analyte under the MRM mode after the chromatographic separation on Waters ACQUITY UPLC BEH C_(18)(50 mm x 2.1 mm, 1.7 μm) column.The limits of quantitation(LOQ) for the 16 dyestuffs were in the range of 1.0-8.0 μg/kg.The mean recoveries at the three spiked levels of 5-100 μg/kg were 81.3%-98.6%, with the intra-day precision less than 11% and the inter-day precision less than 14%.The method is accurate, rapid, sensitive, and adapt to the inspec tion of the 16 dyestuffs in toys.