1.Determination of Catechin Compound in Salacia amplifolia by HPLC
Jiang PU ; Feng FENG ; Ning XIE
Chinese Journal of Information on Traditional Chinese Medicine 2006;0(01):-
Objective To determine the content of ECEGC in Salacia amplifolia by HPLC.Method HYPERSIL C18 column was used with a mixture of methanol and water(30∶70) as mobile phase,and detected at 283 nm.Result The linear range was 0.444 8~7.116 8 ?g(r =0.999 9) for ECEGC.The average recovery was 100.30%.Conclusion The method is simple,rapid,accurate and reliable.
2.Thinking of Deepening National Essential Medicine System Reform
Lin JIANG ; Weibin ZHANG ; Chuan PU
China Pharmacy 2016;27(12):1585-1587
OBJECTIVE:To provide reference for improving the national essential medicine system and satisfy the needs of ra-tional use from the public METHODS:The current situation and existing problems in the national essential system were described by literature research and comparative analysis,and recommendations were presented. RESULTS:The implementation of essential medicine system has certain effects in China,but there still remains some problems,involving too much variety of essential medi-cines,high price and others,and limitation of the use of medicine and distribution in primary medical institutions. CONCLU-SIONS:Government should further simplify the essential medicine lists,reduce prices,strengthen policy support for primary medi-cal institutions,deepen the national essential medicine system and protect the public's rational drug use.
3.Relationship between the erythrocyte CR1 genomic density polymorphism and erythrocyte immune function in children with asthma
Jinhua FENG ; Pu QIN ; Yuhong JIANG
Chinese Journal of Postgraduates of Medicine 2010;33(3):7-9
Objective To explore the hereditary susceptibility of children with asthma through studying the relationship between erythroeyte CR1 genomic density polymorphism and erythrocyte immune function. Methods The rates of RBC-C3_(3b)RR and RBC-ICRR were detected to the asthma group consisted of 65 children with asthma and the control group consisted of 28 normal children. The CR1 activity and genomic density polymorphism of erythrocyte from the two groups were detected by Hind Ⅲ restriction enzyme digestion, polymerase chain reaction restriction fragment length polymorphism. Results Frequencies of high expression gene (HH), mid expression gene (HL) and low expression gene (LL) genotypes were 43.08% (28/65), 36.92% (24/65) and 20.00% (13/65) in asthma group, and 78.57% (22/28), 17.86% (5/28) and 3.57%(1/28) in control group respectively. A significant difference was found in the distribution frequency of CR1 genotype between the two groups(P< 0.01).The rates of RBC-C_(3b)RR were significant lower and the rates of RBC-ICRR were significant higher in asthma group than those in control group (P < 0.01). The rates of RBC-C_(3b) RR in HH, HL and LL were decreased in order (P < 0.01),while the rates of RBC-ICRR in HH,HL and LL were increased in order (P < 0.01). Conclusion It suggests that CR1 gene polymorphism may play an important role in determining susceptibility to asthma.
5.Application of low tube voltage with low concentration contrast agent volume of coronary CTA examination in the diagnosis of coronary artery stenosis
Xiaoming LI ; Jiang PU ; Hongyu DONG
China Medical Equipment 2016;13(3):57-60
Objective:To investigate the effect and application feasibility of low tube voltage, low concentration of contrast agent volume to CTA in the diagnosis of coronary artery stenosis and its effect.Methods: Seventy two cases of suspected patients with coronary atherosclerosis selected as the object Using random number table method, all patients were divided into group A and group B 36 cases in each group, two groups of patients underwent 320 slice CTA examination, in group A the tube voltage is 120kV, the contrast agent was 350mgI/mL iodixanol group, B tube voltage is set to 100kV, the contrast agent was 270mgI/mL iodixanol. According to the examination results of group A, group B and catheter coronary angiography (CCA), evaluated group A, group B of acquiring the image quality and radiation dose of patients, and analyzed the sensitivity of A, B and CCA examination of the extent of coronary artery stenosis degree and deliberately.Results: The quartering method showed no significant difference between the group A and the group B of image quality. There was significant difference between the two groups of patients with the image noise and enhance the effect (t=-4.736, 11.927;P<0.05); Group B of coronary artery stenoses (more than 50%) and severe stenosis (more than 75%) sensitivity, specially degree and coincidence rate compared with the results of CCA showed no significant difference. Kappa consistency analysis showed that the two consistency is good(kappa=1.320,P<0.001).Conclusion: In the premise of ensuring the image quality with low tube voltage, low concentration of contrast agent volume coronary CTA examination had safety and reliability of inspection.
6.Research on the application value of spiral CT multi period mixed injection tracking method in the diagnosis of pulmonary embolism
Xiaoming LI ; Jiang PU ; Hongyu DONG
China Medical Equipment 2016;13(1):63-66
Objective:To investigate the 256 slice spiral CT pulmonary angiography (CTPA) application value by using multiple stage double mixed injection velocity tracking method in the diagnosis of pulmonary embolism.Methods: Fifty patients with pulmonary embolism from 2014 January to 2015 January were treated in our hospital patients as the research object. Using a random number table method, all patients were randomly divided into observation group and control group, 25 cases each group of patients, two groups of patients in our hospital by imaging with 256 slice spiral CT pulmonary artery (CTPA), the control group were treated by routine pre injection time density curve method, was used in the observation group than in mixed injection agent tracking method by two physicians, CT, using the double-blind assessment of two groups of patients with image quality and quantification of pulmonary artery trunk.Results: in the control group, 25 patients were satisfied with the time - density curve, the results of 5 conventional image quality scores showed no significant difference between the two imaging methods, was not statistically significant; two groups of patients with pulmonary artery trunk, branch clear imaging score and endovascular CT value had no significant difference(t=1.892,t=1.952,t=1.832;P>0.05), but the observation group patients with CTPA were examined by contrast agent dose was significantly lower than the control group, the patient''s heart rate, blood pressure was significantly lower than the control group(t=2.315,t=1.958,t=2.982;P<0.05), with statistical significance. Conclusion: CTPA with multi period mixed double flow injection method can guarantee the tracking based on image quality and diagnostic value can effectively reduce the contrast agent dosage and application effects of cardiac function, and the examination is relatively simple, safe, has clinical value of application and popularization.
7.Seed cells for tissue-engineered heart valves:source and application
Lei PU ; Yaxiong LI ; Lihong JIANG
Chinese Journal of Tissue Engineering Research 2014;(2):277-282
BACKGROUND:Application of mechanical valve and bioprosthetic valve replacement is an effective means for the treatment of end-stage valve disease. However, their clinical application is constrained by multiple factors. Tissue-engineered heart valves with biological activity hold the potential to overcome the defect of the mechanical valves and bioprosthetic valves. Choosing appropriate cells for cellseeding is a significant aspect for the research of tissue-engineered heart valves. A growing number of somatic cells and stem cells have been used for construction of tissue-engineered heart valves, however, not yet achieve the desired result.
OBJECTIVE:To review the studies on seed cells for tissue-engineered heart valves and the cellseeding methods in vitro on the basis of the cellular components of heart valves.
METHODS:First author searched PubMed and Wanfang database with computer for related articles published from January 2000 to December 2012. The keywords were“tissue engineering, heart valves, cel”. Preferred articles concerned seed cells of tissue-engineered heart valves with the relevance and authority. A total of 39 articles published in the prestigious journals were reviewed.
RESULTS AND CONCLUSION:Endothelial cells and interstitial cells were mainly valvular cellular components. In the early stage, endothelial cells and fibroblasts were used to construct tissue-engineered heart valves. With deep stem cellresearch, the application of pulsatile bioreactor cultivation mesenchymal stem cells holds a great potential to produce tissue-engineered heart valves.
8.Comparison of 3 methods in the detection for hepatitis B virus PreS 1 antigen
Jie FU ; Dongneng JIANG ; Xiaoyun PU
International Journal of Laboratory Medicine 2014;(18):2519-2520
Objective To investigate the similarities and differences of 3 methods for detecting hepatitis B virus S 1(PreS1) ,and select the appropriate method for detecting clinical samples .Methods The PreS1 of the serum samples from chronic hepatitis B pa-tients were tested with enzyme immunoassay analyzer ,time-resolved method and the manual method .To compare the repetition rate ,select PreS1 antigen strongly positive serum and weak positive serum were detected 15 times by three methods ;To compare the explicit rate ,the reaction temperature was raised or lowered by 3 ℃ .Results The positive rate of three methods was 93 .53% , 92 .81% ,92 .81% .Automated ELISA reproducibility CV strong positive CV3 .62% ,weakly positive CV was 13 .42% ,CV of time-resolved method for the 2 kinds of samples were 5 .10% ,7 .92% ,manual methods CV 11 .10% 29 .88% ;changing the reaction incu-bation temperature 3 ℃ ,automatic detection ELISA all specimens S/CO value decreased ,increasing the chance of a false negative . The manual methods and time-resolved detection method for all specimens S/CO values increased ,increasing the chance of a false positive .Conclusion The detection rate and repeatability of automated ELISA were better .The time-resolved method followed and the manual methods were poor .
10.Immunosensor construction of label free detection of CD4+T lymphocytes
Xingyu JIANG ; Dongneng JIANG ; Fanfei MENG ; Xiaoyun PU
International Journal of Laboratory Medicine 2017;38(6):753-755,759
Objective To construct an immunosensor for detecting CD4+ T lymphocytes without labeling .Methods The staphy-lococcus protein A(SPA) method was adopted to conduct the oriented immobilization of CD4 monoclonal antibodies on the gold in-terdigitated microelectrode surface for capturing CD4+ T lymphocytes .Then cyclic voltammetry(CV) method was used to conduct the representation of modification situation on the gold interdigitated microelectrode surface .Finally the electrochemical impedance spectroscopy(EIS) was used to detect the impedance of CD4+ T lymphocytes captured by the immunosensor .The standard curve was drawn by the impedance values change obtained by the equivalent electric circuit fitting .Results The linear range of this im-munosensor for detecting CD4+ T lymphocytes was (5 × 103 -5 .0 × 106 )/mL ,with lower detection limit of 5 .0 × 102/mL .Conclu-sion The constructed immunosensor has accurate and reliable detection results uhidn is simple to operate accurate ,convenient and cheap ,which might be expected to be used in the real-time detection system ,and offers help for realizing rapid ,accurate and inex-pensive CD4+ T lymphocyte count .