1.Comparative Study of Pinless Navigation System versus Conventional Instrumentation in Total Knee Arthroplasty
Prashant PAWAR ; Lokesh NAIK ; Dipit SAHU ; Vaibhav BAGARIA
Clinics in Orthopedic Surgery 2021;13(3):358-365
Background:
Optimal placement of the components and achieving a neutral mechanical axis are the main goals of total knee arthroplasty (TKA). Different computerised navigation systems are presently used for these purposes. This aim of this study was to compare the pinless navigation (PNA) TKA performed using iAssist with the conventional instrumented (CIN) TKA in terms of functional and radiological outcomes.
Methods:
A total of 100 knees operated for TKA by a single surgeon were studied retrospectively for a period of 2 years. Weightbearing postoperative radiographs of the knees along with scanograms of the lower limbs were used for measurements of component positioning, mechanical axis alignment, and number of outliers. Oxford knee scoring was used for functional analysis.
Results:
No statistically significant difference was seen in the mean mechanical axis alignment (hip-knee-ankle angle), coronal alignment (α and β angles) and sagittal alignment (γ and δ angles) of the femoral and tibial components between the two groups. Though the percentage of outliers for mechanical axis alignment was lower in the PNA-TKA group than in the CIN-TKA group, the difference was not statistically significant (p = 0.73). The number of outliers for the femoral and tibial component positioning in coronal and sagittal planes was not statistically significantly different between the two groups. No statistically significant difference (p = 0.68) was noted between the two groups with respect to the Oxford Knee Score. The mean surgical time was greater in the PNA-TKA group by 11 minutes, which was statistically significantly longer (p = 0.018). Complications were seen in 6.89% of the cases in the CIN-TKA group, while none in the PNA-TKA group.
Conclusions
The accurate mechanical axis alignment and component positioning can be achieved with the conventional instrumentation, so the use of PNA system, which adds to the surgical cost, is questionable. Also, equally good short-term functional outcome can be achieved with the conventional instrumentation. The surgeon must be accustomed with the instrumentation of the PNA system, or it adds to the surgical time.
2.Comparative Study of Pinless Navigation System versus Conventional Instrumentation in Total Knee Arthroplasty
Prashant PAWAR ; Lokesh NAIK ; Dipit SAHU ; Vaibhav BAGARIA
Clinics in Orthopedic Surgery 2021;13(3):358-365
Background:
Optimal placement of the components and achieving a neutral mechanical axis are the main goals of total knee arthroplasty (TKA). Different computerised navigation systems are presently used for these purposes. This aim of this study was to compare the pinless navigation (PNA) TKA performed using iAssist with the conventional instrumented (CIN) TKA in terms of functional and radiological outcomes.
Methods:
A total of 100 knees operated for TKA by a single surgeon were studied retrospectively for a period of 2 years. Weightbearing postoperative radiographs of the knees along with scanograms of the lower limbs were used for measurements of component positioning, mechanical axis alignment, and number of outliers. Oxford knee scoring was used for functional analysis.
Results:
No statistically significant difference was seen in the mean mechanical axis alignment (hip-knee-ankle angle), coronal alignment (α and β angles) and sagittal alignment (γ and δ angles) of the femoral and tibial components between the two groups. Though the percentage of outliers for mechanical axis alignment was lower in the PNA-TKA group than in the CIN-TKA group, the difference was not statistically significant (p = 0.73). The number of outliers for the femoral and tibial component positioning in coronal and sagittal planes was not statistically significantly different between the two groups. No statistically significant difference (p = 0.68) was noted between the two groups with respect to the Oxford Knee Score. The mean surgical time was greater in the PNA-TKA group by 11 minutes, which was statistically significantly longer (p = 0.018). Complications were seen in 6.89% of the cases in the CIN-TKA group, while none in the PNA-TKA group.
Conclusions
The accurate mechanical axis alignment and component positioning can be achieved with the conventional instrumentation, so the use of PNA system, which adds to the surgical cost, is questionable. Also, equally good short-term functional outcome can be achieved with the conventional instrumentation. The surgeon must be accustomed with the instrumentation of the PNA system, or it adds to the surgical time.
3.Cone-beam computed tomography analysis of accessory maxillary ostium and Haller cells: Prevalence and clinical significance.
Ibrahim K ALI ; Kaustubh SANSARE ; Freny R KARJODKAR ; Kavita VANGA ; Prashant SALVE ; Ajinkya M PAWAR
Imaging Science in Dentistry 2017;47(1):33-37
PURPOSE: This study aimed to evaluate the prevalence of Haller cells and accessory maxillary ostium (AMO) in cone-beam computed tomography (CBCT) images, and to analyze the relationships among Haller cells, AMO, and maxillary sinusitis. MATERIALS AND METHODS: Volumetric CBCT scans from 201 patients were retrieved from our institution's Digital Imaging and Communications in Medicine archive folder. Two observers evaluated the presence of Haller cells, AMO, and maxillary sinusitis in the CBCT scans. RESULTS: AMO was observed in 114 patients, of whom 27 (23.7%) had AMO exclusively on the right side, 26 (22.8%) only on the left side, and 61 (53.5%) bilaterally. Haller cells were identified in 73 (36.3%) patients. In 24 (32.9%) they were present exclusively on the right side, in 17 (23.3%) they were only present on the left side, and in 32 (43.8%) they were located bilaterally. Of the 73 (36.3%) patients with Haller cells, maxillary sinusitis was also present in 50 (68.5%). On using chi-square test, a significant association was observed between AMO and maxillary sinusitis in the presence of Haller cells. CONCLUSION: Our results showed AMO and Haller cells to be associated with maxillary sinusitis. This study provides evidence for the usefulness of CBCT in imaging the bony anatomy of the sinonasal complex with significantly higher precision and a smaller radiation dose.
Archives
;
Cone-Beam Computed Tomography*
;
Humans
;
Maxillary Sinus
;
Maxillary Sinusitis
;
Prevalence*
4.CdS nanocrystals as fluorescent probe for detection of dolasetron mesylate in aqueous solution:Application to biomedical analysis
Pawar P. Samadhan ; Walekar S. Laxman ; Kondekar R. Uttam ; Gunjal B. Dattatray ; Gore H. Anil ; Anbhule V. Prashant ; Patil R. Shivajirao ; Kolekar B. Govind
Journal of Pharmaceutical Analysis 2016;6(6):410-416
A simple and straightforward method for the determination of dolasetron mesylate (DM) in aqueous solution was developed based on the fluorescence quenching of 3-Mercaptopropionic acid (MPA) capped CdS quantum dots (QDs). The structure, morphology, and optical properties of synthesized QDs were characterized by using UV-Vis absorption spectroscopy, fluorescence spectroscopy, transmission electron microscopy (TEM) and dynamic light scattering (DLS) measurements. Under the optimum conditions, the MPA-CdS QDs fluorescence probe offered good sensitivity and selectivity for detecting DM. The probe provided a highly specific selectivity and a linear detection of DM in the range of 2–40 μg/mL with detection limit (LOD) 1.512 μg/mL. The common excipients did not interfere in the proposed method. The fluorescence quenching mechanism of CdS QDs is also discussed. The developed sensor was applied to the quantification of DM in urine and human serum sample with satisfactory results.