1.Comparison of Corneal Thickness Measurements with the Orbscan and Ultrasonic Pachymetry.
Pil Sung KANG ; Yun Sik YANG ; Jae Duck KIM
Journal of the Korean Ophthalmological Society 2000;41(8):1697-1703
To verify the accuracy and reproducibility of corneal thickness measurements obtained with Orbscan (Orbtek, Inc., Salt Lake City, USA), the measurements were compared with those taken with an ultrasound pachymeter (Omega Compuscan, Storz). Central corneal thickness was measured by each method in 100 eyes of 50healthy subjects. The averages by the two methods were compared. One examiner took the measurements twice by each method in 20 eyes of 10 subjects, and intraexaminer reproducibility was evaluated. Two examiners measured the thickness in 20 eyes of 10 subjects and interexaminer reproducibility was assessed. The average corneal thickness was 550.27+/-3.56 micrometer in the Orbscan measurements and 526.62+/-3.70 micrometer in the ultrasound pachymetry: There was a statistically significant difference between the two methods. Significant difference was noticed but this showed a constant corresponding correlation with the Orbscan showing a 4.4%lower average. The intraexaminer and interexaminer reproducibility showed high reliability(Guttman split-half point<0.99). The Orbscan pachymetry is a highly reliable method and may be widely used in clinical practice.
Corneal Pachymetry*
;
Lakes
;
Ultrasonics*
;
Ultrasonography
2.Regional and Socioeconomic Inequality of Atrial Fibrillation with Regular Hospital Visit
Korean Circulation Journal 2018;48(7):635-636
No abstract available.
Atrial Fibrillation
;
Socioeconomic Factors
4.Altered Auditory Event Related Potentials Following Administration of Methylphenidate in Children with Attention Deficit Hyperactivity Disorder.
Bo Moon CHOI ; Yang Sook SUNG ; Sang Ick HAN ; Sung Pil LEE
Journal of Korean Neuropsychiatric Association 1997;36(2):281-291
OBJECTS: Event related potential(ERF) has been recently applied to examine the neurophysiological disturbance in attention deficit hyperactivity disorder(ADHD), particularly with regard to N100 and P300 which are known as one of ERP components closely linked with cognitive function. On the basis of these aspects, this study was designed to evaluate electrophysiologic characteristics and its availability for diagnosis and treatment of ADHD children by comparison of ERP between normal controls and ADHD children before and after methylphenidate (MFD) administration. METHODS: We examined the topographic auditory ERF and T.O.V.A.(Test of variables of attention), a standardized computerized visual continuous performance test following administration of stimulant drug, MPD 10mg in 13 ADHD children and compared these results with those of 11 normal controls. RESULTS: The results were as follows: 1) Thought the difference was not spastically significant(P=0.0548), N100 latencies seemed to be longer in ADHD children than in normal controls. N100 amplitudes also seemed to be larger in ADHD children than in normal controls(P=0.0629). 2) The F300 latencies significantly shortened after MFD administration when compared with those before MPD administration in ADHD group(P<0.01). 3) ADHD group performed significantly less well than normal controls in T.O.V.A.(P<0.05). And T.O.V.A. scores significantly improved after MFD administration in ADHD group(P<0.01). 4) The N100 and P300 latencies and the T.O.V.A. scores were significantly correlated before MPD administration in ADHD group(P<0.05). 5) The F300 latencies before MFD administration were significantly correlated with the amplitudes of changes of T.O.V.A. scores after MFD administration(P<0.05). CONCLUSION: It seems that prolonged N100 latency of ADHD children can be regarded as a relatively enduring trait marker and that F300 latency may reflect attentional response ability along with therapeutic effect by stimulant.
Attention Deficit Disorder with Hyperactivity*
;
Child*
;
Diagnosis
;
Evoked Potentials*
;
Humans
;
Methylphenidate*
;
Muscle Spasticity
5.Reproducibility of Perifoveal Fluorescent Dots Velocity Measurements on Fluorescein Angiography with a Scanning Laser Ophthalmoscope.
Yun Sik YANG ; Pil Sung KANG ; Soo Hwaan LEE ; Jae Duck KIM
Journal of the Korean Ophthalmological Society 2000;41(2):433-438
To evaluate the reproducibility in measuring the velocities of perifoveal hyperfluorescent dots, we analyzed fluorescein angiographs of 24 eyes[24 patients]which had central serous retinopathy. Fluorescein angiography was performed with a scanning laser ophthalmoscope[SLO, Rodenstock, Mnchen, Germany]Distances between 5 moving hyperfluorescent dots in a perifoveal capillary were measured at each consecutive frame[interval 1/30 sec]. And then velocities of 5 fluorescent dots were measured with image analysis program by converting the distances to real retinal size using the Littmann's curve in 20 eyes. In the other 4 eyes, the velocities between 5 fluorescent dots of each 2 to 4 capillaries were measured. Perifoveal capillary mean blood flow velocity and standard deviation were 2.08 +/-0.36 mm/sec, and mean coefficient of variation of the velocities measured in a vessel of one patient was 12.58%. However, reliability of the velocities of 2 to 4 capillaries on the 4 eyes was relatively low. In conclusion, the measurement of velocities between perifoveal fluorescent dots with scanning laser ophthalmoscope may be a reproducible method for a perifoveal capillary. However, reliability of measuring velocities was not sufficient enough to use the velocity of one perifoveal capillary as macular blood flow.
Blood Flow Velocity
;
Capillaries
;
Central Serous Chorioretinopathy
;
Fluorescein Angiography*
;
Fluorescein*
;
Humans
;
Ophthalmoscopes*
;
Retinaldehyde
6.Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuick(TM) EB implant system.
Jong Hwa KIM ; Young Kyun KIM ; Yang Jin YI ; Pil Young YUN ; Hyo Jung LEE ; Myung Jin KIM ; In Sung YEO
The Journal of Advanced Prosthodontics 2009;1(3):136-139
STATEMENT OF PROBLEM: Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been few clinical studies surveying the success rates of immediate loading, based on Korean implant systems. PURPOSE: The aim of this study was to evaluate the outcome of immediate functional loading of the implant (SinusQuick(TM) EB, Neobiotech Co., Seoul, Korea) in partially edentulous maxilla or mandible. MATERIAL AND METHODS: Total 15 implants were placed. Within 2 weeks after implant insertion, provisional implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months. RESULTS: Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was 0.03 +/- 0.07 mm, 0.16 +/- 0.17 mm and 0.29 +/- 0.19 mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate. CONCLUSION: Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.
Dental Implants
;
Denture, Partial, Fixed
;
Follow-Up Studies
;
Humans
;
Mandible
;
Maxilla
;
Prospective Studies
;
Sample Size
;
Survival Rate
7.A Case of Purtscher's Retinopathy Responsive to High-dose Steroid Therapy.
Jun HEO ; Young Chang LEE ; Sung Won YANG ; Seong Taek KIM ; Pil Joong YANG
Journal of the Korean Ophthalmological Society 2008;49(3):509-513
PURPOSE: To report a case of high dose steroid-responsive Purtscher's retinopathy which was developed after operation for diaphragmatic laceration sustained in motorcycle accident. CASE SUMMARY: A 68-year-old man came to our hospital with complaining of decreased visual acuity in the right eye after diaphragmatic laceration operation. Best corrected visual acuity was 0.1 in the right eye. Anterior segment was nonspecific. However, afferent pupillary defect was observed. Superficial intraretinal hemorrhage, numerous cotton-wool spots, peripapillary hemorrhage, and macular edema were detected on fundus examination. Fluorescein angiography revealed capillary nonperfusion and fluorescein filling defect due to retinal hemorrhage in arteriovenous phase and fluorescein leakage from the macula and capillary nonperfusion area in the late venous phase. Accordingly, Purtscher's retinopathy was diagnosed and the patient was observed without specific treatment. After 2 weeks of observation, symptoms and fundus findings were not changed. High-dose steroid therapy was begun with injection of one gram of methylprednisone for three days, switched to oral prednisolone, and then slowly tapered in period of 3 weeks. 7 days after the treatment, visual acuity was improved to 0.2 in the right eye but afferent pupillary defect was still observed. Cotton-wool spots slightly decreased, peripapillary hemorrhage was absorbed but macular edema was remained. 14 days after the treatment, visual acuity greatly improved to 0.63 and afferent pupillary defect was not observed. Cotton-wool spots and macular edema were decreased but fluoroscein leakage from capillary nonperfusion area was remained. CONCLUSIONS: In the case of Purtscher's retinopathy, high-dose steroid therapy can be a useful management method for the improvement of visual acuity and other symptoms.
Aged
;
Capillaries
;
Eye
;
Fluorescein
;
Fluorescein Angiography
;
Hemorrhage
;
Humans
;
Lacerations
;
Macular Edema
;
Motorcycles
;
Porphyrins
;
Prednisolone
;
Pupil Disorders
;
Retinal Hemorrhage
;
Visual Acuity
8.NEXUS and the Canadian Cervical Spine Rule as a Screening Tool for Computed Tomography Evaluation in Patients with Cervical Spine Injury.
Yang Hwan CHOI ; Junho CHO ; Minhong CHOA ; Yoo Seok PARK ; Hyun Soo CHUNG ; Sung Pil CHUNG
Journal of the Korean Society of Traumatology 2008;21(1):15-21
PURPOSE: National Emergency X-Radiography Utilization Study (NEXUS) criteria and the Canadian Cervical Spine rule (CCR) are commonly used in cervical trauma patients to determine whether a plain cervical X-ray should be performed. However, plain cervical X-rays are so inaccurate that cervical spine computed tomography (CT) is often considered as a screening test. We studied the usefulness of the NEXUS criteria and the CCR for determining the need for a CT evaluation in the emergency department (ED). METHODS: This prospective observational study was conducted from January 2007 to March 2008. Plain Xray and CT scans of the cervical spine were performed on blunt trauma patients with neck pain. The relevancy of CT was examined using the NEXUS criteria and the CCR. Sensitivity, specificity, positive predicted value, and negative predicted value analyses were performed to diagnose the cervical spine injury. RESULTS: During the study period, 284 patients were enrolled in this study. The sensitivity, specificity, positive predicted value, and negative predicted value of the NEXUS criteria were 87.5%, 1.1%, 5.0%, and 60.0% respectively, while those of the CCR were 87.5%, 8.2%, 5.3%, and 91.6%. There were two missed fracture cases when the NEXUS criteria and the CCR were applied independently, however, no cases were missed when both were applied. CONCLUSION: This study suggests the NEXUS and the CCR in combination can be used as a guide to CT evaluation for cervical spine injury in the ED.
Cervical Vertebrae
;
Emergencies
;
Female
;
Humans
;
Mass Screening
;
Neck Pain
;
Prospective Studies
;
Resin Cements
;
Sensitivity and Specificity
;
Spine
9.A Case of Subdermal Basal Cell Carcinoma.
Sung Woo CHOI ; Jeung Eun YANG ; In Gang JANG ; Hyung Ok KIM ; Seong Pil JOH
Korean Journal of Dermatology 1997;35(5):1036-1039
Basal cell carcinomas usually arise from the epidermis and show some epidermal connections. It is very unusual that basal celi carcinomas occur as subderrnal mass without epidermal connections. A 51 year-old female h;d an asymptomatic skin colored indurated plaque with linear old scar on the left side of nose fcr about 20 years. She had had a tumor that supposed to be a epidermal cyst, on the same site and the lesion was excised about 20 years ago. We performed the punch biopsy on her first visit which revealed hypertrophic scar. She was treated with intralesional injection of triamcinolone acetonide to reduce the size of hypertrophic scar. However, the lesion had not been reduced. She underwent the surgery to remove the scar at plastic surgery and the excisional biopsy showed a subdermal basal cell carcinoma. We recommend that the newly developed skin tumor in the pre-excised region should be required excisional biopsy instead of punch and close observation
Biopsy
;
Carcinoma, Basal Cell*
;
Cicatrix
;
Cicatrix, Hypertrophic
;
Epidermal Cyst
;
Epidermis
;
Female
;
Humans
;
Injections, Intralesional
;
Middle Aged
;
Nose
;
Skin
;
Surgery, Plastic
;
Triamcinolone Acetonide
10.Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy.
Su Sung KIM ; Mong Sook VANG ; Hong So YANG ; Sang Won PARK ; Hyun Pil LIM
The Journal of Advanced Prosthodontics 2009;1(1):41-46
STATEMENT OF PROBLEM: The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE: This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND METHODS: Disks of commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy were cast. Specimens without the primer were also prepared and used as the controls. The shear bond strengths were measured on a screw-driven universal testing machine. RESULTS: The primers significantly (P < .05) improved the shear bond strengths of the heat cure resin to all metals. However, the specimens primed with the Alloy primer(R) (MDP monomer) showed higher bond strength than those primed with the MR bond(R) (MAC-10 monomer) on titanium. Only adhesive failure was observed at the metal-resin interface in the non-primed specimens, while the primed specimens showed mixed failure of adhesive and cohesive failure. CONCLUSIONS: The use of appropriate adhesive metal primers makes it possible not only to eliminate the need for surface preparation of the metal framework before applying the heat cure resins, but also reduce the need for retentive devices on the metal substructure. In particular, the Alloy primer(R), which contains the phosphoric acid monomer, MDP, might be clinically more acceptable for bonding a heat cure resin to titanium than a MR bond(R), which contains the carboxylic acid monomer, MAC-10.
Adhesives
;
Alloys
;
Collodion
;
Denture Bases
;
Dentures
;
Hot Temperature
;
Metals
;
Phosphoric Acids
;