4.Application and exploration of Smile Lite MDP portable photography system in aesthetic photography of anterior teeth.
Min LIU ; Jun Dang ZHANG ; Hong Qiang YE ; Yi Jiao ZHAO ; Xu Bin ZHAO ; Wen Yan ZHAO ; Yun Song LIU ; Yong Sheng ZHOU
Journal of Peking University(Health Sciences) 2020;52(1):187-192
OBJECTIVE:
To explore the possibility of the Smile Lite MDP (Smile Lite Mobile Dental Photograph) portable dental photography system applying in anterior teeth aesthetic photography, and to provide the chance to simplify aesthetic photography process and facilitate communication among patients, dentists and dental technitians.
METHODS:
The Smile Lite MDP photography system combined with the smartphone were used to photograph the front occlusal phase photos of anterior teeth. The photographic conditions including the color temperature parameter, the Smile Lite MDP light position and the intensity settings were explored. The best photographic conditions were chosen by blind evaluation within experienced dentists and technicians through the method of the visual analogue scale/score (VAS) evaluation, which went through statistical analysis to figure out the optimum photograghic conditions. Smile Lite MDP photography system was used to photograph the front occlusal phase photos of anterior teeth under the optimum parameter by different magnifications. The width/height ratio of the central incisor and the front width ratio of the upper anterior teeth in those photos were measured and calculated respectively. The accuracy of the anterior teeth photos taken by Smile Lite MDP photography system was analyzed based on the photographs taken by digital single lens reflex (DSLR) camera.
RESULTS:
The optimum color temperature parameter of Smile Lite MDP portable camera system was 5 000 K, the optimum magnification was 4 times, the best light position was the side lights of Smile Lite MDP, the optimum intensity of lights was 2 grades. Photos taken by the optimum parameters won the highest score during the VAS evaluation and the result of statistical analysis had significant difference compared with other groups (P<0.05). When comparing the photos of the upper anterior teeth taken by the Smile Lite MDP portable photography system using 4 times magnification or by DSLR using the standard parameters, there was no significant difference neither in the width/hieght ratio of the central incisor nor in the front width ratio of the upper anterior teeth (P>0.05).
CONCLUSION
The Smile Lite MDP portable dental photography system applying in anterior teeth aesthetic analysis photography was capable to show the color and shape of anterior teeth in an accurate way by using the right photography parameters. Therefore, Smile Lite MDP portable dental photography system was considered to be a simple and easy photographic tool in clinical work.
Esthetics
;
Esthetics, Dental
;
Humans
;
Incisor
;
Photography
;
Smiling
5.Comparison of traditional dental plaque indices with real stained plaque area.
Ji Soo KIM ; Yong Hoon YANG ; Eun Joo JUN ; Jin Bom KIM ; Seung Hwa JEONG
Journal of Korean Academy of Oral Health 2017;41(4):262-266
OBJECTIVES: The aim of this study was to compare Plaque Percent Index (PPI), calculated by Patient Hygiene Performance Index (PHPI), Rustogi's modification of the Navy Plaque Index (RMNPI), and the Quigley & Hein Plaque Index (QHPI), with visual assessment. METHODS: Ninety-six subjects, aged between 30–65 years, were examined; twenty subjects were included in the final analysis. The subjects' teeth were stained and photographed. Dental coloring and intraoral camera photography were performed by a single examiner. The oral images obtained were analyzed using Image J to measure the area of dental plaque. The values of PHPI, RMNPI, and QHPI were calculated twice. Statistical analyses were performed using descriptive statistics, chi-square test, and Pearson's correlation coefficient. RESULTS: The results of the correlation analyses of PPI with PHPI, QHPI, and RMNPI were as follows: for PHPI, the correlation coefficient (r)=0.584; for QHPI, r=0.689; and for RMNPI, r=0.729. Further, the kappa indices of PHPI, QHPI, and RMNPI were 0.810, 0.677, and 0.590 respectively. CONCLUSIONS: Among RMNPI, QHPI, and PHPI dental plaque indices, RMNPI and QHPI showed a high degree of correlation with the actual stained dental plaque area; on the other hand, PHPI showed the highest kappa index.
Dental Plaque Index*
;
Dental Plaque*
;
Hand
;
Humans
;
Hygiene
;
Photography
;
Tooth
6.Application of digital photography in color matching in dentistry.
Xiao-ting SHEN ; Yi FAN ; Li LIU ; Yan-zhen ZHANG
Journal of Zhejiang University. Medical sciences 2011;40(4):432-435
OBJECTIVETo develop a new color matching method in dentistry by application of digital photography.
METHODSDigital photographs were obtained of Vitapan 3D-Master shade guide and natural teeth under the same condition, the L*a*b* values of each digital photography were assessed and analyzed by Photoshop CS4.
RESULTSThe Vitapan 3D-Master shade guide was divided into 5 groups, the L* values were similar in each group, but decreased from group 1 to 5. The a* values of L1.5 and L2.5 were minimum, R1.5 and R2.5 were maximum and M1-M3 were intermediate. Compared with Vitapan 3D-Master shade guide, the L*a*b* values of natural teeth were higher.
CONCLUSIONDigital photography can basically reflect the color of Vitapan 3D-Master shade guide, and provides a reference for color matching in dentistry.
Adult ; Color ; Colorimetry ; methods ; Humans ; Photography, Dental ; methods ; Prosthesis Coloring
7.Analysis of dental plaque by using cellular neural network-based image segmentation.
Qing-xian LUAN ; Xiao LI ; Jia-yin KANG ; Jin-zhu LIU ; Le-quan MIN
Chinese Journal of Stomatology 2007;42(12):720-722
OBJECTIVETo establish and evaluate a new method for measurement of dental plaque by using cellular neural network-based image segmentation.
METHODSA total of 195 subjects were selected from community population. After dental plaque staining, oral digital picture of anterior teeth area was taken by an Olympus digital camera (C-7070 Wide Zoom). At the same time, the Turesky dental plaque indices of anterior teeth were evaluated. The image analysis was conducted by cellular neural network-based image segmentation.
RESULTSThe image cutting errors between two operators were very small. The Kappa value is 0.935. Pearson's correlation coefficient is 0.988 (P < 0.001). There was high correlative consistency between traditional dental plaque index and plaque percentage obtained by using image analysis. Pearson's correlation coefficient was 0.853 (P < 0.001).
CONCLUSIONSCellular neural network-based image segmentation is a new method feasible for evaluating dental plaque.
Dental Plaque ; diagnosis ; Dental Plaque Index ; Female ; Humans ; Image Processing, Computer-Assisted ; Male ; Neural Networks (Computer) ; Photography, Dental
8.Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?.
Ming Xu JIN ; Min Ho HONG ; Kee Joon LEE ; Kyu Bok LEE
The Journal of Advanced Prosthodontics 2016;8(2):125-130
PURPOSE: The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the acquisition of frontal view photographs, derive these ratios for Korean adults on the basis of the data obtained, and analyze them using the Golden Proportion as a reference. MATERIALS AND METHODS: In experiment I, 30 plaster casts were mounted on an articulator and positioned on the angle-measuring device with a center setting of 0°. The device was rotated to 10° in 1° increments in a counterclockwise direction. At each angle, photographs were obtained and analyzed. Experiment II was based on 60 patients who visited the Department of Prosthodontics at Kyungpook National University Dental Hospital from February 2012 to February 2015. The patients were divided into three groups [Male (M), Female (F), Total (M + F)]. Frontal views were obtained for all groups and analyzed. RESULTS: From 1° to 10°, the relative mesiodistal width ratios for the maxillary anterior teeth showed no significant differences from those at 0°. In all three groups, the relative width ratio of the maxillary central incisor was smaller than that specified in the Golden Proportion; the opposite was true for the canine. CONCLUSION: Our results suggest that the mesiodistal width ratios of the maxillary anterior teeth do not follow the Golden Proportion in Korean adults, and that a change in the horizontal plane angle from 1° to 10° during frontal photography does not affect these ratios.
Adult*
;
Casts, Surgical
;
Dental Articulators
;
Female
;
Gyeongsangbuk-do
;
Humans
;
Incisor
;
Photography
;
Prosthodontics
;
Tooth
9.Soft Tissue Change in Frontal View after Orthognathic Surgery for Class III Malocclusion: Analysis Using Facial 'Phi' Mask
Young Min HEO ; Hong Soek KIM ; Jun Young PAENG ; Jongrak HONG ; Chang Soo KIM
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons 2011;33(6):490-496
10.Analysis of the effect of contact strength on three-dimensional displacement of an implant-supported fixed bridge under axial-concentrated load using digital laser speckle photography.
Jun WANG ; Zhenzhen PENG ; Aijie LI ; Zujie XU ; Xinmin CHEN
Journal of Biomedical Engineering 2013;30(6):1235-1243
The purpose of this study was to investigate the effect of four kinds of different contact strength on the three-dimensional displacement of an implant-supported fixed bridge using digital laser speckle photography method. An in vitro model of beagle mandible with an implant-supported fixed bridge in its right premolar region was developed. The bridge was Au-Pt metal-ceramic. The contact was recovered to four different tightnesses, named 0, 1, 2, and 3. Different axial concentrated static load was applied to abutments and bridge respectively. The three-dimensional displacement of the implant-supported fixed bridge was measured using digital laser speckle photographic method. The results demonstrated that the influence of contact tightness was mainly on the mesio-distal and buccal lingual parts. When the contact tightness reached number 3, the regularity of displacement distribution was changed. The present study proved that digital laser speckle photography was an effective method of measuring the micro-displacement. One of the criterions of contact recovering decreased the implant displacement effectively without changing the regularity of displacement distribution.
Animals
;
Dental Prosthesis, Implant-Supported
;
Denture, Partial, Fixed
;
Diagnostic Imaging
;
methods
;
Dogs
;
Lasers
;
Mandible
;
Models, Animal
;
Photography