1.Development and verification of reversed-phase high-performance liquid chromatography for determination of residual phenylmethanesulfonyl fluoride in recombinant virus-like particle vaccine stock solution
Chinese Journal of Biologicals 2025;38(03):323-329
Objective To develop a reversed-phase high-performance liquid chromatography(RP-HPLC) method for the determination of residual phenylmethanesulfonyl fluoride(PMSF) content in recombinant virus-like particle(VLP) vaccine stock solution,and to verify the method for the determination of PMSF residues in recombinant VLP vaccine stock solution.Methods A RP-HPLC method for the determination of PMSF residues was developed by screening detection wavelength,flow rate,injection amount and chromatographic column.The specificity,linearity and range,limit of quantitation(LOQ),limit of detection(LOD),accuracy,precision and durability of the method were verified.The developed method was used to detect PMSF residues in three batches of recombinant hepatitis E vaccine stock solution.Results The RP-HPLC method was developed,with ChromCore 300 C18(4.6 mm × 250 mm,5 μm) as the chromatographic column at the column temperature of 25 ℃,the detection wavelength of 210 nm,the injection amount of 100 μL,0.1% trifluoroacetic acid(TFA)/water and0.1% TFA/acetonitrile as mobile phase at a flow rate of 1 mL/min,and the detection time of 18 min.The absorption peaks of PMSF control and vaccine stock solution containing PMSF appeared around 5.0 min,while the vaccine stock solution and stock solution buffer showed no absorption peak.There was a good linear relationship between the concentration of PMSF control and peak area in the range of 0-5.0 μg/mL,with R~2 of 0.999.The LOQ and LOD of this method was 0.250 μg/mL and 0.125 μg/mL,respectively.The recovery rates of PMSF control with high,medium and low concentrations were all between 90% and 110%.The relative standard deviations(RSDs) of retention time,peak height and peak area for the determination of instrument repeatability,sample repeatability and intermediate precision were all less than 5%.The RSDs of retention time,peak height and peak area were all less than 5% under the TFA concentration of 0.09%,0.1% and 0.11% at column temperature of 20,25 and 30 ℃.PMSF was not detected in the three batches of recombinant hepatitis E vaccine stock solution.Conclusion The developed RP-HPLC method has good specificity,linearity and durability,high accuracy and precision,and can be used to detect residual PMSF content in recombinant VLP vaccine stock solution.
Phenylmethanesulfonyl fluoride(PMSF)
;
Reversed-phase high-performance liquid chromatography(RP-HPLC)
;
Virus-like particle(VLP) vaccine