1.Establishment and Evaluation of Diabetic Macrovascular Atherosclerosis Model with Qi and Yin Deficiency Syndrome
Ting LUO ; Qingzhi LIANG ; Xi PENG ; Yi SU ; Hongyan XIE ; Chunguang XIE
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(13):86-98
ObjectiveTo explore the establishment of a rat model of diabetic macrovascular atherosclerosis (DMA) with Qi and Yin deficiency syndrome induced by high-fat diet, streptozotocin (STZ), and Yin-depleting herbs, and to evaluate its biological characteristics. MethodsForty SD rats were randomly divided into a blank group (n=10) and a modeling group (n=30). Except for the blank group, rats in the model group were fed a high-fat diet for 4 weeks, followed by intraperitoneal injection of STZ (30 mg·kg-1) to establish a diabetic model. Twenty-four successfully modeled diabetic rats were randomly divided into a model group (n=7), a Qi and Yin deficiency syndrome group (n=8), and a counter-syndrome group (n=9). Except for the model group, rats received intragastric administration of Yin-depleting herbs (1.2 g·kg-1) for 8 weeks. The counter-syndrome group was further treated with Shenqi compound formula (1.69 g·kg-1) for an additional 8 weeks. General condition and body weight were recorded, and syndrome-related indicators were assessed, including precordial temperature, skin moisture content, grip strength, open-field test performance, and tongue appearance. Serum levels of vascular endothelial growth factor (VEGF), endothelin-1 (ET-1), vascular cell adhesion molecule-1 (VCAM-1), insulin-like growth factor-1 (IGF-1), and monocyte chemotactic protein-1 (MCP-1) were measured by enzyme-linked immunosorbent assay (ELISA). Fasting blood glucose, blood lipids, hemorheological parameters, and coagulation function were analyzed using an automatic biochemical analyzer. Vascular ultrasound and hematoxylin-eosin (HE) staining were used to evaluate vascular lesions. ResultsIn terms of syndrome manifestations, compared with the blank group, body weight increased rapidly during the first 5 weeks in the model, Qi and Yin deficiency, and counter-syndrome groups. After STZ injection combined with Yin-depleting herbal administration at week 5, body weight decreased significantly (P<0.01) and continued to decline until the end of the experiment. Rats exhibited decreased activity, irritability, coarse and yellowish fur with obvious shedding, polydipsia, polyphagia, frequent urination, and dry stools, which were most pronounced in the Qi and Yin deficiency group. Grip strength decreased, peak activity time occurred earlier, total distance in the open-field test was reduced, and residence time was prolonged. Precordial temperature decreased (P<0.01), while paw temperature increased (P<0.05), and skin moisture and oil content were reduced (P<0.05, P<0.01). In terms of disease-related indicators, compared with the blank group, fasting blood glucose was significantly increased (>16.7 mmol·L-1) in the model and Qi and Yin deficiency groups, and blood lipid levels were significantly elevated (P<0.05). Vascular-related factors ET-1, MCP-1, VCAM-1, and VEGF were significantly increased (P<0.05,P<0.01), while IGF-1 was significantly decreased (P<0.01). Pathological examination of the aortic valve showed valvular thickening and structural disorganization. Carotid artery examination revealed discontinuity of the intima, foam cell accumulation beneath the intima, disordered smooth muscle arrangement, and widened intercellular spaces. Compared with the model group, ET-1, MCP-1, and VEGF levels were significantly decreased in both the Qi and Yin deficiency group and the counter-syndrome group. The reductions in ET-1 and MCP-1 were more pronounced in the Qi and Yin deficiency group (P<0.01), while the decrease in VCAM-1 was more significant in the counter-syndrome group (P<0.05). Compared with the blank group, the Qi and Yin deficiency group showed significantly prolonged activated partial thromboplastin time (APTT), thrombin time (TT), and prothrombin time (PT) (P<0.01). The erythrocyte deformability index (TK), erythrocyte sedimentation rate, erythrocyte electrophoresis index, and whole blood low-shear viscosity all showed increasing trends. Vascular ultrasound revealed reduced arterial blood flow velocity, increased vascular resistance, and intimal thickening without plaque formation. The aortic intima showed no obvious overall thickening, with only occasional localized thickening and foam cell presence, and carotid artery injury was observed. ConclusionA rat model of DMA with Qi and Yin deficiency syndrome was successfully established using high-fat diet feeding combined with STZ injection and Yin-depleting herbal administration. Shenqi compound formula effectively alleviated Qi and Yin deficiency syndrome, regulated glucose and lipid metabolism, improved hemorheological and coagulation function, reduced vascular lesion severity, and demonstrated potential for early prevention and treatment of DMA.
2.Reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur with a 3D printed modular supporting prosthesis
Minxun LU ; Linyun TAN ; Xin HU ; Zihan PENG ; Zhuangzhuang LI ; Wacili DA ; Xuanhong HE ; Weiyi WANG ; Yitian WANG ; Yi LUO ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(10):686-692
Objective:To observe the early clinical efficacy of 3D-printed modular supporting prosthesis for reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur.Methods:From May 2018 to July 2023, a total of 9 patients with giant cell tumor of the distal femur were treated with 3D-printed modular supporting prosthesis to reconstruct lacunar bone defects in the Department of Orthopedics, West China Hospital, Sichuan University. There were 4 males and 5 females, aged 30.8±6.1 years (range, 24-44 years), 5 cases on the left side, 4 cases on the right side, 2 cases of Campanacci grade I, 7 cases of Campanacci grade II. The anteroposterior and lateral X-ray films and T-SMART tomosynthesis imaging of the knee joint were taken to observe the bone graft healing and osseointegration after operation. Musculoskeletal Tumor Society (MSTS)-93 was used to evaluate knee function, and visual analogue scale (VAS) was used to evaluate knee pain.Results:All patients were successfully operated and followed up for an average of 30.8±7.5 months (range, 18-42 months). The operation time was 124.2±23.6 min, and the intraoperative blood loss was 105.6±17.4 ml. All autografts showed bony union at the graft-host junction, and the healing time was 3.3±0.4 months (range, 3.0-4.0 months). At 6 months after surgery, T-SMART tomosynthesis imaging showed that the gap between the prosthesis-bone interface was less than 1 mm in all patients. At the last follow-up, the thickness of residual subchondral bone was 5.7±1.3 mm, which was greater than that before operation 2.2±0.8 mm, and the difference was statistically significant ( t=10.823, P<0.001). At the last follow-up, the score of MSTS-93 was 26.7±2.4, which was higher than that before operation 18.8±3.7, and the difference was statistically significant ( t=5.367, P<0.001). At the last follow-up, the range of motion of the knee joint was 122.8°±9.1°, which was higher than that before operation 108.3°±6.1°, and the difference was statistically significant ( t=3.970, P<0.001). All patients were able to walk normally, go up and down stairs and other daily activities, and 7 patients were able to complete squats. At the last follow-up, there was no local tumor recurrence, distant metastasis, death, joint infection, pain (VAS score was 0), delayed wound healing, joint degeneration, prosthesis loosening or articular surface collapse. Conclusion:Reconstruction of lacunar bone defect caused by giant cell tumor of distal femur with 3D-printed modular supporting prosthesis can effectively improve knee joint function and osseointegration, and the short-term clinical results are satisfactory.
3.A study and application of rapid and precise dose measurement based on Gafchromic EBT4 film in FLASH radiotherapy
Yi ZHANG ; Yiwei YANG ; Yinghong TANG ; Shilan WANG ; Peng WU ; Qin YANG ; Xufan HUANG ; Yin LUO ; Yu JIANG ; Wenjun LUO ; Guiqiang ZOU ; Hua FENG ; Yinxiang HU
Chinese Journal of Radiological Medicine and Protection 2025;45(11):1144-1151
Objective:To establish a rapid and precise dose measurement method with EBT4 film and ensure its measurement accuracy to be within the required range through strict operational procedures for the purpose of addressing the two essential issues of poor measurement accuracy and timeliness of EBT film under FLASH conditions.Methods:After storing under different humidity conditions for a certain period of time, the film was exposed to radiation for analyzing the influence of air humidity on the intrinsic performance of EBT film. By means of repeated scanning operations and the film angle rotation, the influences of repeated scanning and film placement angle were analuzed. Parabolic correction method was used to reduce the spatial position influence during the scanning process. By analying the relationship between net optical density (netOD) and absorbed dose through the comparison of three fitting method, the optimal fitting curve was selected. After irradiation of the same batch of films for 5 min and 24 h, the film doses were calibrated and then compared with ionization chamber-measured result. The rapid and precise film dosimetry method was used to measure both the percentage depth dose from X-rays at ultra-high dose rate and the dose distribution at a depth of 2 cm in water.Results:Air humidity had the greatest influence on the intrinsic performance of EBT film (approximately 20%). The average deviation of repeated scans is within 0.5%. The angle at which the film is placed significantly affected the readouts of the film with the maximum influence approximately 70%. The net optical density combined with polynomial fitting can control the fitting residuals of 1-16 Gy within 3%. The change rate of light channels at 5 min already mostly met the requirements of the rapid mode (< 0.5%). Compared with the measurement result obtained using the reference ionization chamber, the deviations of the 5 min or 24 h dose calibration curves were all within 2%.Conclusions:The EBT4 film can be employed as a precise dosimeter to quickly measure the FLASH radiation dose. Rapid and precise FLASH dose measurements can meet the stringent requirements of both preclinical and clinical FLASH research.
4.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
5.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
6.Analysis of the Application Effect of Curved Incision Surgery in the Treatment of Hammock Finger Tendon
Huan LUO ; Hao PENG ; Wei-hao ZHENG ; Peng-yu XU ; Song-bai WANG ; Zi-yi GUO
Progress in Modern Biomedicine 2025;25(9):1542-1548
Objective:To investigate the application effect of curved incision surgery in the treatment of hammock finger tendon.Methods:45 patients with hammock finger tendon who were admitted to Pingle Orthopedics and Traumatology Hospital in Shenzhen were selected from May 2022 to May 2023,all of whom were treated with curved incision surgery.Wound healing,functional recovery and complication rate were observed after surgery.Results:In this study,45 patients with hammock finger tendon were successfully followed up for 3 to 18 months,with an average follow-up of 1 year.The results of follow-up showed that all the incisions healed in one stage,and there were no complications such as skin infection and necrosis,exposed knots and skin irritation.X-ray reexamination before and after the operation showed,no complications such as loosening of the Kirkner needle,redisplacement of bone mass and nonunion of bone.During the follow-up period,there was no significant recurrence of vertical deformity.Crawford grading showed that,35 cases were excellent,9 were good,and 1 was fair.Conclusion:Using curved incision surgery to treat hammock finger tendon,which has the advantages of less trauma,faster recovery and fewer complications,and the effect is good.
7.Reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur with a 3D printed modular supporting prosthesis
Minxun LU ; Linyun TAN ; Xin HU ; Zihan PENG ; Zhuangzhuang LI ; Wacili DA ; Xuanhong HE ; Weiyi WANG ; Yitian WANG ; Yi LUO ; Chongqi TU ; Li MIN
Chinese Journal of Orthopaedics 2025;45(10):686-692
Objective:To observe the early clinical efficacy of 3D-printed modular supporting prosthesis for reconstruction of lacunar bone defect caused by giant cell tumor of the distal femur.Methods:From May 2018 to July 2023, a total of 9 patients with giant cell tumor of the distal femur were treated with 3D-printed modular supporting prosthesis to reconstruct lacunar bone defects in the Department of Orthopedics, West China Hospital, Sichuan University. There were 4 males and 5 females, aged 30.8±6.1 years (range, 24-44 years), 5 cases on the left side, 4 cases on the right side, 2 cases of Campanacci grade I, 7 cases of Campanacci grade II. The anteroposterior and lateral X-ray films and T-SMART tomosynthesis imaging of the knee joint were taken to observe the bone graft healing and osseointegration after operation. Musculoskeletal Tumor Society (MSTS)-93 was used to evaluate knee function, and visual analogue scale (VAS) was used to evaluate knee pain.Results:All patients were successfully operated and followed up for an average of 30.8±7.5 months (range, 18-42 months). The operation time was 124.2±23.6 min, and the intraoperative blood loss was 105.6±17.4 ml. All autografts showed bony union at the graft-host junction, and the healing time was 3.3±0.4 months (range, 3.0-4.0 months). At 6 months after surgery, T-SMART tomosynthesis imaging showed that the gap between the prosthesis-bone interface was less than 1 mm in all patients. At the last follow-up, the thickness of residual subchondral bone was 5.7±1.3 mm, which was greater than that before operation 2.2±0.8 mm, and the difference was statistically significant ( t=10.823, P<0.001). At the last follow-up, the score of MSTS-93 was 26.7±2.4, which was higher than that before operation 18.8±3.7, and the difference was statistically significant ( t=5.367, P<0.001). At the last follow-up, the range of motion of the knee joint was 122.8°±9.1°, which was higher than that before operation 108.3°±6.1°, and the difference was statistically significant ( t=3.970, P<0.001). All patients were able to walk normally, go up and down stairs and other daily activities, and 7 patients were able to complete squats. At the last follow-up, there was no local tumor recurrence, distant metastasis, death, joint infection, pain (VAS score was 0), delayed wound healing, joint degeneration, prosthesis loosening or articular surface collapse. Conclusion:Reconstruction of lacunar bone defect caused by giant cell tumor of distal femur with 3D-printed modular supporting prosthesis can effectively improve knee joint function and osseointegration, and the short-term clinical results are satisfactory.
8.A study and application of rapid and precise dose measurement based on Gafchromic EBT4 film in FLASH radiotherapy
Yi ZHANG ; Yiwei YANG ; Yinghong TANG ; Shilan WANG ; Peng WU ; Qin YANG ; Xufan HUANG ; Yin LUO ; Yu JIANG ; Wenjun LUO ; Guiqiang ZOU ; Hua FENG ; Yinxiang HU
Chinese Journal of Radiological Medicine and Protection 2025;45(11):1144-1151
Objective:To establish a rapid and precise dose measurement method with EBT4 film and ensure its measurement accuracy to be within the required range through strict operational procedures for the purpose of addressing the two essential issues of poor measurement accuracy and timeliness of EBT film under FLASH conditions.Methods:After storing under different humidity conditions for a certain period of time, the film was exposed to radiation for analyzing the influence of air humidity on the intrinsic performance of EBT film. By means of repeated scanning operations and the film angle rotation, the influences of repeated scanning and film placement angle were analuzed. Parabolic correction method was used to reduce the spatial position influence during the scanning process. By analying the relationship between net optical density (netOD) and absorbed dose through the comparison of three fitting method, the optimal fitting curve was selected. After irradiation of the same batch of films for 5 min and 24 h, the film doses were calibrated and then compared with ionization chamber-measured result. The rapid and precise film dosimetry method was used to measure both the percentage depth dose from X-rays at ultra-high dose rate and the dose distribution at a depth of 2 cm in water.Results:Air humidity had the greatest influence on the intrinsic performance of EBT film (approximately 20%). The average deviation of repeated scans is within 0.5%. The angle at which the film is placed significantly affected the readouts of the film with the maximum influence approximately 70%. The net optical density combined with polynomial fitting can control the fitting residuals of 1-16 Gy within 3%. The change rate of light channels at 5 min already mostly met the requirements of the rapid mode (< 0.5%). Compared with the measurement result obtained using the reference ionization chamber, the deviations of the 5 min or 24 h dose calibration curves were all within 2%.Conclusions:The EBT4 film can be employed as a precise dosimeter to quickly measure the FLASH radiation dose. Rapid and precise FLASH dose measurements can meet the stringent requirements of both preclinical and clinical FLASH research.
9.Analysis of the Application Effect of Curved Incision Surgery in the Treatment of Hammock Finger Tendon
Huan LUO ; Hao PENG ; Wei-hao ZHENG ; Peng-yu XU ; Song-bai WANG ; Zi-yi GUO
Progress in Modern Biomedicine 2025;25(9):1542-1548
Objective:To investigate the application effect of curved incision surgery in the treatment of hammock finger tendon.Methods:45 patients with hammock finger tendon who were admitted to Pingle Orthopedics and Traumatology Hospital in Shenzhen were selected from May 2022 to May 2023,all of whom were treated with curved incision surgery.Wound healing,functional recovery and complication rate were observed after surgery.Results:In this study,45 patients with hammock finger tendon were successfully followed up for 3 to 18 months,with an average follow-up of 1 year.The results of follow-up showed that all the incisions healed in one stage,and there were no complications such as skin infection and necrosis,exposed knots and skin irritation.X-ray reexamination before and after the operation showed,no complications such as loosening of the Kirkner needle,redisplacement of bone mass and nonunion of bone.During the follow-up period,there was no significant recurrence of vertical deformity.Crawford grading showed that,35 cases were excellent,9 were good,and 1 was fair.Conclusion:Using curved incision surgery to treat hammock finger tendon,which has the advantages of less trauma,faster recovery and fewer complications,and the effect is good.
10.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.

Result Analysis
Print
Save
E-mail