1.Value of ultrasound in diagnosing ductal carcinoma in situ
Rongrong GUO ; Fang CHANG ; Peixia WANG ; Chenxiang DU ; Li ZHANG
Cancer Research and Clinic 2009;21(11):739-741
Objective To evaluate the value of ultrasound in diagnosing ductal carcinoma in situ (DCIS). Methods The sonographic characteristics of 12 DCIS which were confirmed by pathology were analyzed retrospectively. Results The ultrasound image of DCIS could be divided into four types;the solid mass nodule, mammary dysplasia, mix mass nodule, the dilated duct type. Micro calcification had high incidence rate. Ultrasonic diagnosis accordance rate was 50.0 %. On molybdenum target mammograms, the tumor appeared as a cluster of calcified spots in 8 cases, and the accuracy rate of diagnosis of was 66.7 %.Conclusion There are no typical characters of DCIS in ultrasound image. However, some characteristics are suggestive and can help to differentiate them from the benign tumors, such as small nodule, irregular shape,obscure boundary, and microcalcification. When sonography combine with molybdenum target mammography,the accuracy rate of diagnosis will be improved.
2.Effects of ozoned water on joint synovium in knee osteoarthritis of rabbits
Peixia GUO ; Youlong ZHOU ; Zhen ZHANG ; Tieli DONG
The Journal of Clinical Anesthesiology 2016;32(4):376-379
Objective To evaluate the effects of ozoned water on the synovial inflammation in rabbits with knee osteoarthritis.Methods Thirty-two rabbits were randomly and evenly divided into four groups by random number method.All the rabbits were made into osteoarthritis models except those in groups A and D.After the osteoarthritis models were made successfully,rabbits in groups C and D received intra-articular injection of ozoned water of 20 μg/ml (2 ml)once a week for three weeks,and the other two groups did not.The morphology of synovium was observed and the expres-sion levels of IL-6 and TNF-α in the synovium were compared among the four groups.Results In group A,there was no hyperemia,edema or cell hyperplasia in the synovium,and the synovium re-mained normol tissue structure.In group B,the synovial structure was damaged,with serious cell hyperplasia,masses of inflammatory cells invading,vascular proliferation and hyperemia,and signifi-cantly increased synovium thickness compared with the normal.In group C,synovial hyperemia and edema were improved,the inflammatory cells reduced,and the synovium thickness was thinner than that in group B.And the group D had no synovitis phenomenon.Compared with group A,the expres-sions of IL-6 and TNF-αwere slightly higher in group D,and they were significantly increased (P <0.05)in the other two groups.Compared with group B,the IL-6 and TNF-α contents of synovium were reduced (P < 0.05)in group C.Conclusion Injecting 2 ml ozoned water of 20 μg/ml into artic-ular cavity can significantly improve synovial inflammation and reduce the expression of IL-6 and TNF-αin the synovium,which does no damage normal synovium.