1.Surgical technique and effectiveness of titanium elastic nail assisted retrograde channel screw implantation in superior pubic branch.
Xiaotian CHEN ; Xiaopan WANG ; Peishuai ZHAO ; Renjie LI ; Junliang JIA ; Min WU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):431-437
OBJECTIVE:
To investigate the surgical technique and effectiveness of titanium elastic nail (TEN) assisted retrograde channel screw implantation of superior pubic branch.
METHODS:
The clinical data of 31 patients with pelvic or acetabular fractures treated with retrograde channel screw implantation in superior pubic branch between January 2021 and April 2022 were retrospectively analyzed. Among them, 16 cases were implanted with assistance of TEN (study group) and 15 cases were implanted under the guidance of C-arm X-ray machine (control group). There was no significant difference in gender, age, cause of injury, Tile classification of pelvic fracture, Judet-Letournal classification of acetabular fracture, and time from injury to operation between the two groups ( P>0.05). The operation time, fluoroscopy times, and intraoperative blood loss of each superior pubic branch retrograde channel screw were recorded during operation. X-ray films and three-dimensional CT were reexamined after operation, the quality of fracture reduction was evaluated by Matta score standard, and the position of channel screw was evaluated by screw position classification standard. The fracture healing time was recorded during the follow-up, and the postoperative functional recovery was evaluated by Merle D'Aubigne Postel score system at last follow-up.
RESULTS:
Nineteen and 20 retrograde channel screws of superior pubic branch were implanted in the study group and the control group, respectively. The operation time, fluoroscopy times, and intraoperative blood loss of each screw in the study group were significantly less than those in the control group ( P<0.05). According to the postoperative X-ray films and three-dimensional CT, none of the 19 screws in the study group penetrated out of the cortical bone or into the joint, and the excellent and good rate was 100% (19/19); in the control group, there were 4 screws of cortical bone penetration, and the excellent and good rate was 80% (16/20); the difference between the two groups was significant ( P<0.05). Matta score standard was used to evaluate the quality of fracture reduction, there was no patient in the two groups with poor reduction results, and the difference was not significant between the two groups ( P>0.05). The incisions of the two groups healed by first intention, and there was no complication such as incision infection, skin margin necrosis, and deep infection. All patients were followed up 8-22 months, with an average of 14.7 months. There was no significant difference in healing time between the two groups ( P>0.05). At last follow-up, the difference in functional recovery evaluated by the Merle D'Aubigne Postel scoring system between the two groups was not significant ( P>0.05).
CONCLUSION
TEN assisted implantation technique can significantly shorten the operation time of retrograde channel screw implantation of superior pubic branch, reduce the times of fluoroscopy, and have less intraoperative blood loss and accurate screw implantation, which provides a new safe and reliable method for minimally invasive treatment of pelvic and acetabular fractures.
Humans
;
Titanium
;
Fracture Fixation, Internal/methods*
;
Blood Loss, Surgical
;
Retrospective Studies
;
Bone Screws
;
Treatment Outcome
;
Fractures, Bone/surgery*
;
Spinal Fractures
;
Hip Fractures