1.The development of cardiology, the Society of Pediatrics.
Chinese Journal of Pediatrics 2015;53(2):81-83
Cardiology
;
trends
;
Pediatrics
;
trends
;
Societies, Medical
;
trends
2.Effect of ozonated water on physical and chemical properties of vacuum sealing drainage material.
Nan JIANG ; Yunfei MA ; Qingrong LIN ; Anfu CHEN ; Peiran ZHAO ; Guoxin NI ; Bin YU
Journal of Southern Medical University 2013;33(2):290-295
OBJECTIVETo investigate the influence of ozonated water on physical and chemical properties of vacuum sealing drainage (VSD) materials.
METHODSVSD materials (foam and sealing membrane) were immersed in 10 µg/ml ozonated water for 1 h twice daily for 8 days. The foam appearance and microscopic structure of the materials were observed, and tensile tests and Raman spectrum scan were performed assess the effect of ozonated water. Simulated VSD devices were prepared and tested for leakproofness under negative pressure after ozonated water treatment.
RESULTSzonated water treatment for 8 days caused no obvious abnormal changes in the foam appearance or microscopic structure of the materials. The maximum tensile load of foam before and after ozonated water treatment was 4.25∓0.73 kgf and 2.44∓0.19 kgf (P=0.000), the momentary distance when the foam torn before and after intervention was 92.54∓12.83 mm and 64.44∓4.60 mm, respectively (P=0.000). The corresponding results for VSD sealing membrane were 0.70∓0.58 kgf and 0.71∓0.08 kgf (P=0.698), and 99.30∓10.27 mm and 100.95∓18.22 mm (P=0.966), respectively. Raman spectroscopy revealed changes in only several wave intensities and no new chemical groups appeared within the scan range of 400-4000 cm(-1). The VSD device was well hermetic after treatment with ozonated water.
CONCLUSIONExcept for a decreased stretch resistance property of the foam, VSD materials display no obvious changes in physical and chemical characteristics after treatment with ozonated water for 8 days.
Biomedical and Dental Materials ; chemistry ; Drainage ; instrumentation ; methods ; Ozone ; Vacuum ; Water ; chemistry
3.Correlation between the quartering method of nerve root subsidence sign and the cross-sectional area of the narrow segment thecal sac in patients with lumbar spinal stenosis
Jing ZHANG ; Fen WANG ; Li YANG ; Yuanbo MA ; Na LI ; Peiran WANG
Journal of Chinese Physician 2023;25(8):1219-1224
Objective:To study the correlation between the quartering of nerve root subsidence sign (NRS) and the cross-sectional area (CSA) of the narrow segment thecal sac in patients with lumbar spinal stenosis (LSS).Methods:The data of 203 LSS patients in the Fourth People′s Hospital of Hengshui from January 2020 to December 2021 were retrospectively analyzed. All patients underwent MRI cross sectional scanning. The patients were divided into positive type a group ( n=62), positive type b group ( n=32), positive type c group ( n=51), and negative group ( n=58) by NRS quartering method. The minimum CSA, median sagittal diameter (PAD), and lateral recess sagittal diameter of each group were compared. The correlation between NRS quartering classification and the minimum CSA and related indicators of lumbar spinal stenosis was analyzed. Results:The minimum CSA, PAD, and sagittal diameter of the lateral recess in the positive a group, positive b group, and positive c group were all smaller than those in the negative group, while the Visual Analogue Scale (VAS) score and Oswestry Disability Index (ODI) were higher than those in the negative group; The minimum CSA, PAD, and sagittal diameter of the lateral recess in the positive b type and positive c type groups were smaller than those in the positive a type group, while the VAS score and ODI index were higher than those in the positive a type group; The minimum CSA, PAD, and sagittal diameter of the lateral recess in the positive c type group were smaller than those in the positive b type group; The VAS score and ODI index were higher than those of the positive b type group; The differences were statistically significant (all P<0.05). 203 patients were divided into 54 normal cases, 58 mild stenosis cases, 49 moderate stenosis cases, and 42 severe stenosis cases based on the minimum CSA. The coincidence rate between negative NRS and minimal CSA diagnosis as normal was 94.44%(51/54), the coincidence rate between positive type a and minimal CSA diagnosis as mild stenosis was 84.48%(49/58), the coincidence rate between positive type b and minimal CSA diagnosis as moderate stenosis was 53.06%(26/49), and the coincidence rate between positive type c and minimal CSA diagnosis as severe stenosis was 90.48%(38/42). Using the kappa consistency test, the kappa value for quantitative diagnosis of minimum CSA stenosis in NRS and LSS patients was 0.743, indicating good consistency. The kappa values for quantitative diagnosis of NRS, sagittal diameter of lateral recess, and PAD stenosis were 0.271 and 0.335, with poor consistency. NRS typing was negatively correlated with CSA and PAD ( r=-0.723, -0.581, all P<0.001), and positively correlated with VAS score and ODI index ( r=0.473, 0.640, all P<0.001). Conclusions:The NRS quartering method has a good consistency in diagnosing the severity of LSS patients and the minimum CSA of stenosis segments, suggesting that the NRS quartering method can better reflect the degree of Spinal stenosis, which can not only be used as an auxiliary indicator for qualitative diagnosis of LSS, but also has a high value in quantitative diagnosis.
4."Frame and buttress" fixation for the treatment of acetabular quadrilateral fractures
Yizhou WAN ; Kaifang CHEN ; Yan MA ; Keda YU ; Peiran XUE ; Dong YAN ; Xiaodong GUO
Chinese Journal of Orthopaedics 2023;43(14):933-940
Objective:To investigate the efficacy and safety of the "frame and buttress" fixation in the treatment of acetabular quadrilateral fractures.Methods:A total of 26 patients with acetabular quadrilateral fractures treated with the "Frame and buttress" fixation strategy (reconstructing frame and providing buttress for quadrilateral surface) from January 2017 to January 2021 were retrospectively analyzed in the Department of Orthopaedics, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, including 17 males and 9 females, aged 47.7±16.5 years, (range, 25-71 years). There were 13 cases from car accidents, 8 cases from falls, and 5 cases from heavy objects. Quadrilateral fractures were classified according to whether the anterior column (A) and posterior column (P) of the acetabulum were fractured and whether the quadrilateral plate (Q) was partially (1) or completely (2) separated from the two columns. Among these cases, there were 5 cases of type AQ1, 1 case of type AQ2, 1 case of type PQ2, 14 cases of type APQ1 and 5 cases of type APQ2. The "frame and buttress" fixation strategy was used to perform open reduction and internal fixation. The Matta scale was used to assess the quality of resurfacing based on pelvic radiographs, and the Matta modified Merle d'Aubigne and Postel scores were referenced to evaluate hip function.Results:All the 26 patients successfully completed the operation, the operation time was 88.1±57.8 min (range, 90-320 min), the intraoperative bleeding was 753.8±309.5 ml (range, 400-1 400 ml). There were 14 cases of anatomical reduction, 8 cases of satisfactory reduction and 4 cases of unsatisfactory reduction with an excellent rate of 85% (22/26), the excellence rate was 85% (22/26). All patients were followed up for 16.3±4.3 months (range, 12-24 months). The hip function score after operation was higher than that before operation, and the difference was statistically significant ( F=19.80, P<0.001). The hip function score was 13.1±2.2 at 3 months postoperatively, increased to 15.9±2.3 at 6 months postoperatively, and increased to 16.6±1.9 at the last follow-up, with a statistically significant difference ( P<0.001). After operation, 5 patients showed symptoms of lateral femoral cutaneous nerve injury such as hypoesthesia and numbness in the anterolateral thigh. During the follow-up, there was no ectopic ossification, traumatic arthritis, necrosis of the femoral head and central dislocation of the femoral head. Conclusion:The "frame and buttress" fixation strategy based on quadrilateral fracture typing for acetabular quadrilateral fracture open reduction internal fixation provides strong fixation, satisfactory reduction quality, and facilitates joint function recovery after operation.