1.Analysis of the Effect of Vitapex Paste in the Root Canal for Deciduous Teeth with Chronic Apical Periodontitis
Li GUO ; Xi CHEN ; Pei LI ; Tong LIN ; Ying FENG
Progress in Modern Biomedicine 2017;17(27):5287-5289
Objective:To investigate the effect of Vitapex paste in the root canal for deciduous teeth with chronic apical periodontitis.Methods:200 children with chronic apical periodontitis were selected and divided into two groups.The observation group (108 cases)was given Vitapex paste.The control group (92 cases) was given Zinc oxide iodoform paste.The effect of Vitapex paste in root canal for deciduous teeth with chronic apical periodontitis was evaluated by filling quality after 1 month'treatment,the VAS scores before and after treatment,long-term curative effect were compared between two groups.Results:After 1 month'treatment,the suitable filling rate of observation group was higher than that of the control group(P<0.05).There was no statistical significance in the VAS scores between two groups (P>0.05).After 1 week'and 1 month'treatment,the pain feeling were alleviated in two groups and significantly lighter in the observation group(P<0.05).After 6 months' follow-up,the success rate was 96.3% in the observation group and 87.0% in the control group,the success rate of observation group was higher than that of the control group (P<0.05).Conclusion:The filling process of Vitapex paste was simple and easy,which had a good therapeutic effect on chronic apical periodontitis of deciduous teeth and could relieve the toothache of patients.
2.Preparation of andrographolide-loaded solid dispersions
Dongyuan SHAN ; Ying PEI ; Qing MENG ; Tong LI
Chinese Traditional Patent Medicine 2017;39(4):719-723
AIM To prepare the andrographolide-loaded solid dispersions.METHODS Differential scanning calorimetry (DSC) and X-ray powder diffraction (XRPD) were used for the analysis of solid dispersions previously prepared from the mixture of andrographolide and PVPK30 (1 ∶ 9) in autoclave.In addition to the evaluation index of in vitro dissolution rate,the influencing factors of pressure,temperature and reaction time were taken into consideration for the preparation optimization by Box-Behnken method.RESULTS Andrographolide was totally dispersed in solid dispersions in an amorphous state,manifesting an inhibited crystal diffraction peaks' formulation.Under the optimal conditions of 21.26 MPa for pressure,40.76 ℃ for temperature,and 1.13 h for reaction time,the in vitro dissolution rate was 85.49%.CONCLUSION After andrographolide is made into solid dispersions,its in vitro dissolution rate is obviously increased.
3.Internal fixation with lag screws plus an anti-sliding plate for the treatment of Hoffa fracture of the lateral femoral condyle.
Li-lai ZHAO ; Pei-jian TONG ; Lu-wei XIAO
China Journal of Orthopaedics and Traumatology 2016;29(3):266-269
OBJECTIVETo explore the clinical effects of internal fixation with lag screws plus an anti-sliding plate for the treatment of Hoffa fractures of the lateral femoral condyle.
METHODSFrom May 2006 to May 2014, 17 patients with Hoffa fractures of the lateral femoral condyle were treated with lag screws plus an anti-sliding plate. There were 13 males and 4 females, ranging in age from 27 to 59 years, with a mean of 32.5 years. All the fractures were fresh and closed fractures. According to the Letenneur's classification, 8 cases were type I, 4 cases were type II, 5 cases were type III. All the patients had no injuries of the cruciate ligament and the another part of the knee. Operative incision and fracture healing time were observed, knee joint function was evaluated by Letenneur system and HSS standard.
RESULTSThe patients were followed up from 10 to 24 months with a mean of 14.6 months. All incisions achieved primary healing, and no internal fixation breakage, malunion, femoral candyle necrosis, deep vein thrombosis of lower extremity were found. Fracture healing time was from 4 to 9 months with an average of 4.7 months. According to Letenneur's functional assessment, 10 patients got an excellent results, 4 good, 3 fair. Total HSS score was 91.1 +/- 4.7 on average,15 cases obtained excellent results, 2 good.
CONCLUSIONInternal fixation with lag screws and an anti-sliding plate can result in excellent effects for Hoffa fractures of the lateral femoral condyle. The key to a successful surgery is an anatomic reduction and rigid fixation of the fracture.
Adult ; Bone Plates ; Bone Screws ; Female ; Femoral Fractures ; physiopathology ; surgery ; Femur ; injuries ; surgery ; Fracture Fixation, Internal ; Fracture Healing ; Fractures, Closed ; physiopathology ; surgery ; Humans ; Ligaments, Articular ; surgery ; Male ; Middle Aged
4.Annlication of external fixator combined with damage control treatment for open fracture of the extremities.
Shun-dong LI ; Chao XU ; Pei-jian TONG
China Journal of Orthopaedics and Traumatology 2015;28(2):130-135
OBJECTIVETo investigate the application and effects of external fixator under the guidance of damage control therapy in limb open fracture.
METHODSFrom May 2008 to January 2013,72 cases with severe limb open fractures (Unincor- porated shock) were divided into control group and observation group (36 cases in each group). In observation group, 36 patients (including 22 males and 14 females) were treated by external fixator at stage I, as soon as possible after waiting for patients physiology conditions being stable,the stage II fracture operation was performed. In control group, 36 patients (24 males and 12 females) were treated by the first stage open reduction. The hospital admission time, open fracture severity score (OFSS),operation duration,operative blood loss,X-ray expose times, callus appear time, fracture healing time, postoperative infection rate, complications and Johner-Wruhs accceccment were recorded and evaluated.
RESULTSAll patients were followed up for 8 to 12 months (10.4 in averaged). The mean operation duration, operative blood loss, callus appear time, fracture healing time the mean operation duration reespectively were (56.79±8.87) min, (216.16±18.21) ml, (5.32±0.71) weeks, (12.79±2.52) weeks in observation group,and (104.53±9.28) min, (439.93±14.65) ml, (4.97±1.26) weeks, (14.81±2.63) weeks in control group. According to Johner-Wruhs acccecement,there were were 33 cases in excellent,2 in good,and 1 in poor in observation group,non-union of fracture in 1 case,local infection occurred in 1 cases; in control group 25 cases in excellent,6 in good, and 5 in poor, non-union of fracture in 1 case,local infection occurred in 8 cases. There were significant differences in operation duration, operative blood loss, callus appear time, fracture healing time, postoperative infection rate, complications (P<0.05). There were no significant differences in hospital admission time, open fracture severity score and X-ray expose times (P>0.05).
CONCLUSIONUnder the guidance of damage control therapy,using external fixator measures to treat patients with open fractures of limbs is worth popularizing in clinical application because it can shorten the operation time, less blood loss, reduce the infection rate and complications, improve the success rate of surgery and recovery rate.
Adult ; Aged ; External Fixators ; Extremities ; injuries ; surgery ; Female ; Fracture Healing ; Fractures, Open ; surgery ; Humans ; Male ; Middle Aged ; Operative Time ; Postoperative Complications ; epidemiology
5.Progress on peri-operative hidden blood loss after hip fracture.
Shun-dong LI ; Chao XU ; Pei-jian TONG
China Journal of Orthopaedics and Traumatology 2014;27(10):882-886
Hip fracture patients preoperative and postoperative exist hidden blood loss which often affect patients' wound healing, increase the probability of infection, prolong rehabilitation exercise, influence postoperative effect. At the same time, the body's blood loss increase the activation of the blood clotting mechanism, promote the incidence of deep vein thrombosis, bleeding and deep vein thrombosis has become the main causes of high risk in hip operation. It is very important to stop bleeding, anticoagulation should not be ignored, so how to effectively deal with the prominent contradiction between the postoperative anticoagulation and bleeding or looking for a best balance has become a intractable problems in hip fracture treatment.
Anticoagulants
;
therapeutic use
;
Blood Loss, Surgical
;
prevention & control
;
Hip Fractures
;
complications
;
surgery
;
Humans
;
Intraoperative Complications
;
drug therapy
;
etiology
;
prevention & control
6.Anti-arrhythmic effects of U50,488H involving the inhibition of Na~+ current in ischemia/reperfusion rat heart
Juan LI ; Haitao GUO ; Hui BI ; Li TONG ; Baozhen WEI ; An XIAO ; Yuemin WANG ; Jianming PEI
Chinese Pharmacological Bulletin 1987;0(03):-
Aim To investigate the effects of U50,488H(a selective ?-opioid receptor agonist)on ventricular arrhythmias induced by myocardial ischemia and reperfusion in rats and to elucidate their mechanisms.Methods The contents of CK(creatine phosphokinase)and LDH(lactate dehydrogenase)were measured; The isolated heart was perfused using langendorff equipment. Heart rate(HR), arterial blood pressure(ABP), left ventricular pressure (LVP), cardiac function (?dp/dtmax), rate of ventricular tachycardia(VT)and ventricular fibrillation(VF)were examined in rats in vitro. The incidence of ventricular arrhythmias and arrhythmia score were also determined; The change of sodium currents (INa) induced by U50,488H was detected by whole-cell recording mode using patch clamp.Results ① In comparison with I/R group, the contents of CK、LDH in plasma of rats in U50,488H+I/R group were significantly lowered(P
7.Protective effects of salidroside on oxidative damage in fatigue mice.
Li MA ; Donglian CAI ; Huaixing LI ; Bende TONG ; Ying WANG ; Suping PEI
Journal of Integrative Medicine 2009;7(3):237-41
To study the protective effects of salidroside on oxidative damage in fatigue mice.
8.Treatment of non-traumatic femoral head avascular necrosis by perfusion of bone marrow stromal stem cells through optional artery.
Pei-Jian TONG ; Fu-Sheng YE ; Shan-Xing ZHANG ; Ju LI ; Liu XIN-QI
China Journal of Orthopaedics and Traumatology 2014;27(7):565-569
OBJECTIVETo study the medium and long term effects of perfusion of bone marrow stromal stem cells through optional artery for the treatment of non-traumatic femoral head avascular necrosis.
METHODSFrom January 2000 to December 2004,62 cases(78 hips) with non-traumatic femoral head necrosis accepted optional artery marrow stromal stem cells infusion treatment and had complete follow-up data, including 43 hips of 35 males and 35 hips of 27 females with an average age of 36.3 years old (22 to 54). According to preoperative imaging data, 16 hips were ARCO I stage, 52 hips were II stage, 10 hips were III a stage. Harris score was 64.94 +/- 8.12 preoperatively. Postoperative Harris score at the last follow-up, imaging changes,DSA vascular changes were analysis.
RESULTSThe patients were followed up for 9 to 13 years (means 11 years). By the end of the follow-up, a total of 18 hips got artificial joint replacement, 10 hips of preoperative ARCO I, II period got artificial hip joint replacement, 8 hips of IIIa period got hip artificial joint replacement. Harris score was 71.21 +/- 0.19 at the end of the follow-up, it was obviously enhanced compared with preoperative. DSA showed blood vessels of supply the femoral head increased thickening.
CONCLUSIONPerfusion of bone marrow stromal stem cells through optional artery can effective treat non-traumatic femoral head necrosis of ARCO I, II period, it can make the femoral circumflex artery and its branches increased thickening.
Adult ; Angiography, Digital Subtraction ; Arthroplasty, Replacement, Hip ; Female ; Femur Head Necrosis ; therapy ; Follow-Up Studies ; Humans ; Male ; Mesenchymal Stem Cell Transplantation ; Middle Aged
9.Percutaneous kyphoplasty for the treatment of osteoporotic vertebral compression fracture with degenerative scoliosis.
Hang-bo QU ; Pei-jian TONG ; Wei-feng JI ; Ju LI
China Journal of Orthopaedics and Traumatology 2016;29(1):38-40
OBJECTIVETo evaluate the therapeutic effects of percutaneous kyphoplasty (PKP) for the treatment of osteoporotic vertebral compression fracture (OVCF) with degenerative scoliosis.
METHODSFrom March 2009 to March 2014,121 patients undergoing PKP for the treatment of osteoporotic vertebral compression fracture (OVCF) with degenerative scoliosis were retrospective analyzed. There were 41 males and 80 females,ranging in age from 56 to 92 years with an average of 73.2 years. Preoperative and postoperative 3 d respectively pain visual analogue scale (visual analogue score, VAS) and Oswestry Disability Index assessed pain and functional recovery of patients and preoperative and postoperative 3 d lumbar lordosis, scoliosis Cobb angle were analyzed.
RESULTSAll the patients were followed up, and the duration ranged from 6 to 24 months, with a mean time of 11 months. All the patients achieved success in operation without serious complications. The operation time ranged from 30 to 65 min with an average of 42.2 min. Local leakage of bone cement was not found in canal. The VAS and Oswestry Disability Index at the 3rd day after operation decreased significantly compared with those of the preoperative (P < 0.05), and the lumbar lordosis and scoliosis Cobb angle also improved significantly compared with those of the preoperative (P < 0.05).
CONCLUSIONPercutaneous kyphoplasty (PKP) for the treatment of thoracolumbar scoliosis osteoporotic fracture can significantly improve patients spinal deformity, pain relief, which is worth of recommending.
Aged ; Aged, 80 and over ; Female ; Fractures, Compression ; surgery ; Humans ; Kyphoplasty ; methods ; Male ; Middle Aged ; Osteoporotic Fractures ; surgery ; Scoliosis ; surgery ; Spinal Fractures ; surgery ; Visual Analog Scale
10.Comparison of different models of Sysmex hematology analyzers used for red blood cell count and related parameters
Li KONG ; Jianping WANG ; Lanting TONG ; Weigang CHEN ; Yintao PEI ; Yufei SHI ; Nengjiao GAO
Chinese Medical Equipment Journal 2017;38(5):95-98
Objective To evaluate Sysmex XS-800i,XS-1000i and XE-2100D hematology analyzers when used to detect RBC count,hemoglobin (HGB),hematocrit (HCT),mean corpuscular volume (MCV),mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC).Methods XE-2100D hematology analyzer was calibrated after performance evaluation,and the three analyzers had the intra-day precisions measured with three levels of whole-blood quality control materials.Totally 50 whole-blood specimens were detected with the three analyzers respectively,and statistical analyses and clinically acceptable performance evaluation were carried out on RBC count and the obtained results.Results XE-2100D hematology analyzer met the clinical requirements,and the three analyzers all gained high precisions when used to measure the parameters of the whole-blood quality control materials.The correlation coefficients (r2) respectively between the three analyzers were all higher than 0.95 when used to test the 50 specimens.At all medical decision levels XS-800i and XS-1000i hematology analyzers both gained acceptable detection results except XS-800i hematology analyzer in case of 5.9×1012/L RBC count as well as 35% or 50% HCT.Conclusion Sysmex XS-800i,XS-1000i and XE-2100D hematology analyzers have high precisions and correlations when used to detect RBC count,HGB,HCT and MCV,and contrast test is suggested to be executed periodically to ensure the comparability of tbe result.