1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Genetic profiling and intervention strategies for phenylketonuria in Gansu, China: an analysis of 1 159 cases.
Chuan ZHANG ; Pei ZHANG ; Bing-Bo ZHOU ; Xing WANG ; Lei ZHENG ; Xiu-Jing LI ; Jin-Xian GUO ; Pi-Liang CHEN ; Ling HUI ; Zhen-Qiang DA ; You-Sheng YAN
Chinese Journal of Contemporary Pediatrics 2025;27(7):808-814
OBJECTIVES:
To investigate the molecular epidemiology of children with phenylketonuria (PKU) in Gansu, China, providing foundational data for intervention strategies.
METHODS:
A retrospective analysis was conducted on 1 159 PKU families who attended Gansu Provincial Maternity and Child Care Hospital from January 2012 to December 2024. Sanger sequencing, multiplex ligation-dependent probe amplification, whole exome sequencing, and deep intronic variant analysis were used to analyze the PAH gene.
RESULTS:
For the 1 159 children with PKU, 2 295 variants were identified in 2 318 alleles, resulting in a detection rate of 99.01%. The detection rates were 100% (914/914) in 457 classic PKU families, 99.45% (907/912) in 456 mild PKU families, and 96.34% (474/492) in 246 mild hyperphenylalaninemia families. The 2 295 variants detected comprised 208 distinct mutation types, among which c.728G>A (14.95%, 343/2 295) had the highest frequency, followed by c.611A>G (4.88%, 112/2 295) and c.721C>T (4.79%, 110/2 295). The cumulative frequency of the top 23 hotspot variants reached 70.28% (1 613/2 295), and most variant alleles were detected in exon 7 (29.19%, 670/2 295).
CONCLUSIONS
Deep intronic variant analysis of the PAH gene can improve the genetic diagnostic rate of PKU. The development of targeted detection kits for PAH hotspot variants may enable precision screening programs and enhance preventive strategies for PKU.
Humans
;
Phenylketonurias/epidemiology*
;
Female
;
Male
;
Retrospective Studies
;
Phenylalanine Hydroxylase/genetics*
;
Mutation
;
Child, Preschool
;
China/epidemiology*
;
Child
;
Infant
7.Clinical relevance of distolingual roots and periodontal status in mandibular first molars:a cross-sectional study employing CBCT analysis
MAO FEIFEI ; WANG MENG ; ZHOU SHUAI ; ZHAO YAN ; HUANG JIAPING ; YIN FENGYING ; YANG HAIPING ; DING PEI-HUI
Journal of Zhejiang University. Science. B 2024;25(3):244-253,中插11
Objectives:Distolingual root of the permanent mandibular first molar(PMFM-DLR)has been frequently reported,which may complicate the treatment of periodontitis.This study aimed to assess the morphological features of PMFM-DLR and investigate the correlation between the morphological features of PMFM-DLR and periodontal status in patients with Eastern Chinese ethnic background.Materials and methods:A total of 836 cone beam computed tomography(CBCT)images with 1497 mandibular first molars were analyzed to observe the prevalence of PMFM-DLR at the patients and tooth levels in Eastern China.Among them,complete periodontal charts were available for 69 Chinese patients with 103 teeth.Correlation and regression analyses were used to evaluate the correlation between the morphological features of DLR,bone loss,and periodontal clinical parameters,including clinical attachment loss(CAL),probing pocket depth(PPD),gingival recession(GR),and furcation involvement(FI).Results:The patient-level prevalence and tooth-level prevalence of DLR in mandibular first molars were 29.4%and 26.3%,respectively.Multiple linear regression analysis suggested that bone loss at the lingual site and CAL were negatively affected by the angle of separation between distolingual and mesial roots in the transverse section,while they were significantly influenced by age and the angle of separation between distobuccal and mesial roots in the coronal section.Conclusions:The prevalence of PMFM-DLR in Eastern China was relatively high in our cohort.The morphological features of DLR were correlated with the periodontal status of mandibular first molars.This study provides critical information on the morphological features of DLR for improved diagnosis and treatment options of mandibular molars with DLR.
8. Establishment of a rat model of myocardial hypertrophy by a modified abdominal aortic coarctation method
Yona-Ming HAO ; Han-Jun PEI ; Li LI ; Zhe ZHAO ; Lei GUO ; Cheng-Hui ZHOU
Acta Anatomica Sinica 2024;55(1):120-124
Objective To compare effectiveness between the modified and traditional pressure-overload myocardial hypertrophy(POMH) model by abdominal aorta coarctation (AAC) method. Methods Totally 45 rats were divided into three groups(n = 15 per group), sham group, traditional group, and modified group. In the traditional group, the diameter ol the abdominal aorta was narrowed to 0. 70 mm through a midline incision for 4 weeks; in the modified group, the diameter of the abdominal aorta was narrowed above the left kidney to 0. 45 mm for 1 week, and then the narrowing was lifted postoperatively. The cardiac index, heart weight (HW) /body weight (BW) and left ventricular index, left ventricular weight (LVW)/BW were measured from the heart specimens, and the cross-sectional area of cardiac myocytes, myocardial collagen area, and myocardial collagen area Iraction were measured in the pathological sections by HE staining and Masson staining. Results Compared with the sham group, the differences in end-systolic interventricular septum thickness (IVSs), left ventricular end-systolic posterior wall thickness (LVPWs), HW/BW, LVW/BW, cardiomyocyte cross-sectional area, myocardial collagen area, myocardial collagen area fraction, and brain natriuretic peptide (BNP) expression levels were statistically significant (P<0. 05) in the modilied and traditional groups of rats. The differences in these indices were not statistically significant between the modified and traditional groups (P>0. 05). Conclusion The modified abdominal aortic constriction method used in this experiment is time-saving, stable, homogeneous and easy to replicate, and is a more ideal approach to establish a rat model of POMH.
9.Disease spectrum and pathogenic genes of inherited metabolic disorder in Gansu Province of China
Chuan ZHANG ; Ling HUI ; Bing-Bo ZHOU ; Lei ZHENG ; Yu-Pei WANG ; Sheng-Ju HAO ; Zhen-Qiang DA ; Ying MA ; Jin-Xian GUO ; Zong-Fu CAO ; Xu MA
Chinese Journal of Contemporary Pediatrics 2024;26(1):67-71
Objective To investigate the disease spectrum and pathogenic genes of inherited metabolic disorder(IMD)among neonates in Gansu Province of China.Methods A retrospective analysis was conducted on the tandem mass spectrometry data of 286 682 neonates who received IMD screening in Gansu Provincial Maternal and Child Health Hospital from January 2018 to December 2021.A genetic analysis was conducted on the neonates with positive results in tandem mass spectrometry during primary screening and reexamination.Results A total of 23 types of IMD caused by 28 pathogenic genes were found in the 286 682 neonates,and the overall prevalence rate of IMD was 0.63‰(1/1 593),among which phenylketonuria showed the highest prevalence rate of 0.32‰(1/3 083),followed by methylmalonic acidemia(0.11‰,1/8 959)and tetrahydrobiopterin deficiency(0.06‰,1/15 927).In this study,166 variants were identified in the 28 pathogenic genes,with 13 novel variants found in 9 genes.According to American College of Medical Genetics and Genomics guidelines,5 novel variants were classified as pathogenic variants,7 were classified as likely pathogenic variants,and 1 was classified as the variant of uncertain significance.Conclusions This study enriches the database of pathogenic gene variants for IMD and provides basic data for establishing an accurate screening and diagnosis system for IMD in this region.
10.Analysis of the effects of low/intermediate dose of coagulation factor Ⅷ on 30 adult patients with severe hemophilia A in a single center.
Yan Hui YUAN ; Pei Pei XU ; Yue Yi XU ; Sha LIU ; Xiao Yan SHAO ; Wei Jing ZHANG ; Li GONG ; Min ZHOU ; Bing CHEN ; Rong Fu ZHOU
Chinese Journal of Hematology 2023;44(1):38-42
Objective: To evaluate the clinical effects of low- and intermediate-dose factor Ⅷ (F Ⅷ) prophylaxis in Chinese adult patients with severe hemophilia A. Methods: Thirty adult patients with severe hemophilia A who received low- (n=20) /intermediate-dose (n=10) F Ⅷ prophylaxis at Nanjing Drum Tower Hospital affiliated with Nanjing University Medical College were included in the study. The annual bleeding rate (ABR), annual joint bleeding rate (AJBR), number of target joints, functional independence score of hemophilia (FISH), quality of life score, and health status score (SF-36) before and after preventive treatment were retrospectively analyzed and compared. Results: The median follow-up was 48 months. Compared with on-demand treatment, low- and intermediate-dose prophylaxis significantly reduced ABR, AJBR, and the number of target joints (P<0.05) ; the improvement in the intermediate-dose prophylaxis group was better than that in the low-dose prophylaxis group (P<0.05). Compared with on-demand treatment, the FISH score, quality of life score, and SF-36 score significantly improved in both groups (P<0.05), but there was no significant difference between the two groups (P>0.05) . Conclusion: In Chinese adults with severe hemophilia A, low- and intermediate-dose prophylaxis can significantly reduce bleeding frequency, delay the progression of joint lesions, and improve the quality of life of patients as compared with on-demand treatment. The improvement in clinical bleeding was better with intermediate-dose prophylaxis than low-dose prophylaxis.
Humans
;
Hemophilia A/drug therapy*
;
Factor VIII/therapeutic use*
;
Quality of Life
;
Retrospective Studies
;
Hemarthrosis/prevention & control*
;
Hemorrhage/drug therapy*

Result Analysis
Print
Save
E-mail