1.Experiment Progress in TCM Treatment for Viral Myocarditis
Xuan ZHANG ; Jingyu XU ; Dazhi SUN ; Bei PEI ; Cian ZHANG ; Zhifeng QIN
Chinese Journal of Information on Traditional Chinese Medicine 2015;22(11):131-133
Viral myocarditis (VMC) is normally caused by myocarditis virus infection. Currently, the Western medicine treatment is mainly about symptomatic supportive treatment, while TCM has remarkable efficacy for this disease. This article started from the 4 common mechanisms of VMC, and elaborated the effects of individual and compound preparation, such as antiviral, regulating immune, anti free redical, antioxidation, improving myocardial metabolism, protecting myocardial cells, with a purpose to provide experimental references for TCM application in clinic.
2.Effects of different levels of iodine nutrition on liver typeⅠdeiodinase and brain typeⅡdeiodinase activities in rat
Bei SUN ; Ai-Jun ZUO ; Dong-Chun LIANG ; Gang GUO ; Xue-Qin ZHAO ; Yu-Qin YAN ; Zu-Pei CHEN ; Jing-Yu ZHANG ;
Chinese Journal of Endocrinology and Metabolism 2000;0(06):-
Wistar rats with different levels of iodine nutrition were killed after 3,6 and 12 months of experiments.Serum thyroid hormones were assayed with RIA.The activity of typeⅠdeiodinase(DⅠ)and typeⅡdeiodinase(DⅡ)was measured based on the release of radioiodide from the ~(125)Ⅰ-labeled substrate.The result showed that hypothyroidism reflected by decreased T_4 happened during the initial phase of iodine deficiency.The activity of DⅠand DⅡin rats was raised significantly in iodine deficiency groups.An excess of iodine inhibited DⅠactivity resulting in decreased serum TT_3 and FT_3.However,DⅡactivity increased in rats with iodine excess, attributing to the inactivation of T_3 and T_4 to the substrate of DⅡenzyme.
3.Study of the association between the chemokine CXCL5 and the onset of chronic atrophic gastritis and gas-tric precancerous lesions
Bei PEI ; Yi ZHANG ; Qin SUN ; Yueping JIN ; Xuejun LI
The Journal of Practical Medicine 2024;40(15):2098-2104
Objective To clarify the changes in CXCL5 in serum and gastric tissues of patients with chronic atrophic gastritis(CAG)and precancerous lesions of gastric cancer(PLGC)and to investigate the predictive value of CXCL5 for the diagnosis of CAG and PLGC.Methods This study enrolled 72 participants of CAG admitted to the Department of Splenology and Gastroenterology of the Second Affiliated Hospital of Anhui University of Chinese Medicine from June 2022 to June 2023,with gastroscopy and pathologically confirmed diagnosis,as well as 68 healthy participants who underwent gastroscopy in the same period at our department.We collected clinical information and laboratory results from all participants.The logistic regression analysis methods were used to identify the diagnostic value of serum CXCL5.Furthermore,in order to clarify the role of CXCL5 in the developent of CAG,a total of 15 patients each with CAG,intestinal metaplasia,and dysplasia treated at our hospital from June 2023 to December 2023,and 15 healthy participants were selected.The relationship between the expression of CXCL5 and the degree of clinicopathology was analysed in each group using ELISA,PCR,and immunohistochemistry staining to validate and assess the diagnostic efficacy of CXCL5.Results The study found that several factors were associated with CAG,including family history of tumours,smoking and alcohol consumption history,dietary regularity,Helicobacter pylori infection,the number of lesions,gastric function scores and CXCL5(P<0.05).The ROC curve had an AUC of 1.00 and a Youden index of 0.986,indicating excellent predictive ability.The ELISA results indicated a significantly higher serum CXCL5 expression level in the CAG,intestinal metaplasia,and dysplasia groups compared to the normal group.There was a positive correlation between the serum CXCL5 expression level and the degree of pathology.The PCR and immunohistochemistry staining results indicate that the mRNA and pro-tein expression levels of CXCL5 in gastric tissues of patient groups were significantly higher compared to the nor-mal group.Furthermore,the mRNA and protein expression levels of CXCL5 in gastric tissues were positively correlated with the degree of pathology.Conclusions The results indicate that CXCL5 is highly expressed in the serum and gastric tissues of patients with CAG and PLGC,and its expression level is positively correlated with the degree of pathology.Therefore,CXCL5 could serve as a predictive indicator and a potential therapeutic target for the diagnosis of CAG and PLGC.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Palmitoylation of heat shock protein 90 in mouse sperm.
Rui LI ; Kun LI ; Yue YANG ; Pei-Bei SUN ; Ai-Jun CHEN ; Ya NI
Acta Physiologica Sinica 2017;69(3):298-304
Protein palmitoylation, one of post-translation modifications, refers to the addition of saturated 16-carbon palmitic acid to cysteine residues via the thioester bond. It plays key roles in various functional activities, such as the interaction, stability and location of proteins. Heat shock protein 90 (Hsp90), an important molecular chaperone, has been reported to be involved in sperm capacitation. However, it remains unclear whether protein palmitoylation exists in sperm and whether Hsp90 in sperm is palmitoylated under different physiological conditions. In this study, we examined whether the protein palmitoylation is present in mouse cauda epididymis sperm using acyl-biotin exchange method, predicted the potential palmitoylated sites of Hsp90 by the software CSS-Palm 4.0 and detected the palmitoylated Hsp90 in the mouse sperm from caput epididymis and cauda epididymis by immunoprecipitation. We found that some proteins, approximately 50, 65, 72, 85 and 130 kDa, were palmitoylated in mouse cauda epididymis sperm. Five sites in two Hsp90 isoforms were predicted to be palmitoylated. The results also showed that Hsp90 in mouse sperm was palmitoylated and its palmitoylation level was involved in different physiological conditions: the palmitoylation level of cauda epididymis sperm was higher than that of caput epididymis sperm; and the palmitoylation level after capacitation was much higher than that before capacitation. In conclusion, this study reveals that protein palmitoylation is present in mouse sperm and the palmitoylated Hsp90 is associated with different physiological conditions in sperm.
Animals
;
Epididymis
;
HSP90 Heat-Shock Proteins
;
metabolism
;
Lipoylation
;
Male
;
Mice
;
Palmitic Acid
;
chemistry
;
Sperm Capacitation
;
Spermatozoa
;
metabolism
10.E-26 Transformation-specific Related Gene Expression and Outcomes in Cytogenetically Normal Acute Myeloid Leukemia: A Meta-analysis.
Jian-Fei FANG ; Hai-Ning YUAN ; Yong-Fei SONG ; Pei-Bei SUN ; Xiao-Liang ZHENG ; Xiao-Ju WANG ;
Chinese Medical Journal 2017;130(12):1481-1490
BACKGROUNDThe E-26 transformation-specific related gene (ERG) is frequently expressed in cytogenetically normal acute myeloid leukemia (CN-AML). Herein, we performed a meta-analysis to investigate the relationship between the prognostic significance of ERG expression and CN-AML.
METHODSA systematic review of PubMed database and other search engines were used to identify the studies between January 2005 and November 2016. A total of 667 CN-AML patients were collected from seven published studies. Of the 667 patients underwent intensive chemotherapy, 429 had low expression of ERG and 238 had high expression of ERG. Summary odds ratio (OR) and the 95% confidence interval (CI) for the ERG expression and CN-AML were calculated using fixed- or random-effects models. Heterogeneity was assessed using Chi-squared-based Q- statistic test and I2 statistics. All statistical analyses were performed using R.3.3.1 software packages (R Foundation for Statistical Computing, Vienna, Austria) and RevMan5.3 (Cochrane Collaboration, Copenhagen, Denmark).
RESULTSOverall, patients with high ERG expression had a worse relapse (OR = 2.5127, 95% CI: 1.5177-4.1601, P = 0.0003) and lower complete remission (OR = 0. 3495, 95% CI: 0.2418-0.5051, P< 0.0001). With regard to the known molecular markers, both internal tandem duplications of the fms-related tyrosine kinase 3 gene (OR = 3.8634, 95% CI: 1.8285-8.1626, P = 0.004) and brain and acute leukemia, cytoplasmic (OR = 3.1538, 95% CI: 2.0537-4.8432, P< 0.0001) were associated with the ERG expression. In addition, the results showed a statistical significance between French-American-British (FAB) classification subtype (minimally differentiated AML and AML without maturation, OR = 4.7902, 95% CI: 2.7772-8.2624, P< 0.0001; acute monocytic leukemia, OR = 0.2324, 95% CI: 0.0899-0.6006, P = 0.0026) and ERG expression.
CONCLUSIONHigh ERG expression might be used as a strong adverse prognostic factor in CN-AML.