1.Effectiveness, Preference and Ease of Passive Release Techniques Using a Syringe for Endotracheal Tube Cuff Inflation.
Kyung Choon PARK ; You Dong SOHN ; Hee Cheol AHN ; Ji Yoon AHN ; Seung Min PARK ; Kwang Yun CHO ; Hyuk Sool KWON ; Gyu Chong CHO ; Jung Tae CHOI
Journal of the Korean Society of Emergency Medicine 2010;21(6):795-800
PURPOSE: Inappropriate cuff inflations cause many complications. A conventional pilot balloon palpation technique is insufficient to detect high cuff pressures, but is still preferred. Hence, we conducted this study to identify effectiveness, preference and ease of use of a new estimation technique named "passive release technique" for endotracheal tube cuff inflation. METHODS: Twenty-nine nurses inflated cuffs by a pilot balloon palpation technique in manikins inserted with a 7.5 mm endotracheal tube. Then, being educated about passive release techniques, they inflated cuffs using such a passive release technique. Intracuff pressures and air volumes were measured by manometers and syringes. Preference and ease of use between the two methods were scored using a 10-point Likert scale. RESULTS: For the pilot balloon palpation technique, only 4 nurses (13.8%) inflated cuffs within the normal range of pressures (normal: 15 to 30 mb) with an average of 39.3+/-34.0 cmH2O. For the passive release technique, 19 nurses (65.5%) inflated cuffs within the normal range of pressures with an average of 24.2+/-9.3 cmH2O (McNemar's test, p<0.01). In the pilot balloon palpation technique, inflated air volumes of 7.8+/-2.0 ml were not significantly different from inflated air volumes 8.5+/-1.2 ml (p=0.07) for the passive release technique. But the difference was found to be statistically significant in a variance ratio test (F-test) (p<0.01). In view of preference and ease of use between the two methods, mean values were not statistically different, 7.3+/-2.0 vs. 7.0+/-2.0 and 7.0+/-2.3 vs. 7.3+/-2.4, respectively. CONCLUSION: When direct intracuff measurement is not available, a passive release technique using a syringe is an effective and easy method to achieve cuff inflation.
Inflation, Economic
;
Intubation
;
Manikins
;
Palpation
;
Reference Values
;
Statistics as Topic
;
Syringes
2.Unfounded Reports on Thyroid Cancer.
Journal of Korean Medical Science 2014;29(8):1033-1034
No abstract available.
Bias (Epidemiology)
;
Early Detection of Cancer/*statistics & numerical data
;
Evidence-Based Medicine
;
Humans
;
Incidence
;
Palpation/*statistics & numerical data
;
Reproducibility of Results
;
Republic of Korea/epidemiology
;
Risk Factors
;
Sensitivity and Specificity
;
Survival Rate
;
Thyroid Neoplasms/*diagnosis/*mortality/prevention & control
;
Ultrasonography/*statistics & numerical data
;
Unnecessary Procedures/*statistics & numerical data