1.Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position
Journal of Korean Physical Therapy 2019;31(1):35-39
PURPOSE: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. METHODS: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to α=0.05. RESULTS: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). CONCLUSION: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.
Healthy Volunteers
;
Methods
;
Palpation
;
Reproducibility of Results
2.Evaluation of Reliability of Tensiomyography Measurement.
Jung Hoon CHAI ; Bo Kyeong KIM ; Hyuk Jae CHOI ; Sang Won BAE
The Korean Journal of Sports Medicine 2018;36(3):143-148
PURPOSE: This study is designed to evaluate the reliability for studies of tensiomyography (TMG). TMG can evaluate muscle function noninvasively and selectively. METHODS: We measured 12 male volunteers (age, 26.5±7.6 years; height, 175.3±4.7 cm; weight, 78.8±13.3 kg) in this study and measured TMG during three occasions over 3 consecutive days. None of the participants has had any history of neuromuscular disorders or muscle diseases. Vastus lateralis, vastus medialis (VM), rectus femoris (RF) in quadriceps and biceps femoris, semitendinosus in hamstrings muscles were measured. Coefficient of variation (CV%) and intraclass correlation coefficient (ICC) have been calculated about maximal displacement (Dm, mm) and contraction time (Tc, ms) which are main parameters. RESULTS: Most of the ICC of Dm were over 0.8 and the highest among the muscles except both VM. And, most ICC of Tc was lower than Dm except both BF (right, 18.31; left, 15.03). But, the ICC of Tc was lower than Dm except left RF (0.890) and VM (0.859). CONCLUSION: This study has shown that the Dm is high levels of the ICC and CV(%) in thigh muscle except VM. In the future, we plan to establish the method of measurement more clearly for reducing the errors of measurements. The technique of correct palpation of measurable muscles using TMG devices is also necessary.
Humans
;
Male
;
Methods
;
Muscles
;
Palpation
;
Quadriceps Muscle
;
Thigh
;
Volunteers
3.Application of palpation in various acupuncture schools of the United States: current status and considerations.
Xin ZHENG ; Qun-Ce ZHANG ; Ye-Meng CHEN ; Hui LI ; Tian-Fang WANG
Chinese Acupuncture & Moxibustion 2010;30(7):591-594
Palpation is one of the major diagnostic methods in Chinese medicine. The article has summed up the current status, features and origins of various palpations in different acupuncture schools in the United States, including palpation on meridian, collaterals and acupoints in traditional Chinese acupuncture, abdominal palpation of Japanese acupuncture, pulse checking for couples in five-element acupuncture, palpation on tendon straps and muscle response testing in acupuncture physical medicine. Since great importance has always been attached on social psychological factors in all acupuncture schools of America, it is thus concluded that the interactive mechanism of diagnosis and treatment represented by palpation feedback examination is not only the manifestation of people oriented individualized treatment both physically and psychologically in America, but also a kind of inheritance and development of diagnosis and treatment in the modernization of TCM.
Acupuncture
;
education
;
Humans
;
Medicine, Chinese Traditional
;
methods
;
Palpation
;
methods
;
United States
4.Thyroid Fine-Needle Aspiration Practice in the Philippines.
Journal of Pathology and Translational Medicine 2017;51(6):555-559
Fine-needle aspiration (FNA) is a well accepted initial approach in the management of thyroid lesions. It has come a long way since its introduction for nearly a century ago. In the Philippines, FNA of the thyroid was first introduced 30 years ago and has been utilized until now as a mainstay in the diagnosis of thyroid malignancy. The procedure is performed by pathologists, endocrinologists, surgeons, and radiologists. Most pathologists report the cytodiagnosis using a combination of the aspiration biopsy cytology method that closely resembles the histopathologic diagnosis of thyroid disorders and the six-tier nomenclature of The Bethesda System for Reporting Thyroid Cytopathology. Local endocrinologists and surgeons follow the guidelines of the 2015 American Thyroid Association in the management of thyroid disorders. There is still a paucity of local research studies but available data deal with cytohistologic correlations, sensitivity, specificity, and accuracy rates as well as usefulness of ultrasound-guided FNA. Cytohistologic correlations have a wide range of sensitivity from 30.7% to 73% and specificity from 83% to 100%. The low sensitivity can be attributed to poor tissue sampling since a majority of the thyroid FNA is done by palpation only. The reliability can be improved if FNA is guided by ultrasound as attested in both international and local studies. Overall, FNA of the thyroid has enabled the diagnosis of thyroid disorders with an accuracy of 72.8% to 87.2% and it correlates well with histopathology.
Biopsy, Fine-Needle*
;
Biopsy, Needle
;
Cytodiagnosis
;
Diagnosis
;
Methods
;
Palpation
;
Philippines*
;
Sensitivity and Specificity
;
Surgeons
;
Thyroid Gland*
;
Ultrasonography
5.The Effectiveness of Fine-Needle Aspiration Conducted by The Otolaryngologists.
Ju Hyung JEONG ; Bon Min KOO ; Hyuk Ki CHO ; Soon Yong HAN ; Chang Ki YEO
Korean Journal of Otolaryngology - Head and Neck Surgery 2016;59(12):843-847
BACKGROUND AND OBJECTIVES: To investigate the effectiveness of fine needle aspiration (FNA) conducted by the otolaryngologists, we compared the ultrasound (US)-guided FNA results conducted by a radiologist (RD-US), the US-guided FNA results (ENT-US), and the palpation guided FNA results (ENT-palpation) conducted by an otolaryngologist. SUBJECTS AND METHOD: 1646 patients who underwent FNA were classified according to the site and periods of investigation (2007-2015), and their sampling adequacy was retrospectively reviewed. They were also divided into three groups (ENT-US, ENT-palpation, and RD-US); each group was then investigated for sampling adequacy. Results of further surgical excisional biopsy were compared with the those of the FNA results to investigate the diagnostic accuracy of all three groups. RESULTS: The sampling adequacy identified by the groups showed the result of ENT-US at 87.9%, ENT-palpation at 87.1% and RD-US at 91.3%. The periodical inadequacy rate failed to show any significant differences between the groups. The sensitivity of ENT-palpation was lower than other two groups. Diagnostic accuracy identified by the groups showed the result of ENT-US at 95.2%, ENT-palpation at 93.6%, and RD-US at 97.4%. CONCLUSION: FNA performed by otolaryngologists demonstrates the effectiveness of diagnosis and treatment, and that doing so would improve economic efficiency. Therefore, it is recommended that well-trained otolaryngologists conduct FNA actively.
Biopsy
;
Biopsy, Fine-Needle*
;
Diagnosis
;
Humans
;
Methods
;
Palpation
;
Retrospective Studies
;
Ultrasonography
6.Exploratory Study on Guide Wire-Guided Tongue Resection under Ultrasonography for Adequate Safe Margins in Tongue Cancer Surgery.
Hyun Jung LIM ; Young Ju JIN ; Eun Jae CHUNG ; J Hun HAH
Korean Journal of Otolaryngology - Head and Neck Surgery 2016;59(5):373-376
BACKGROUND AND OBJECTIVES: The adequate safety margin in tongue cancer is the most important prognostic factor for local recurrence and survival. This study aimed to evaluate the resection margins using a new technique of tongue resection under the guidance of guide wire under ultrasonography in patients with tongue cancer. SUBJECTS AND METHOD: In this prospective study, 10 patients with presurgical, biopsy-proven, clinical T1 or T2 tongue squamous cell carcinomas underwent resection under the guidance of guide wire inserted using ultrasonography. The data of resection margins of 37 patients who underwent partial glossectomy using the conventional method of palpation were used as control data. RESULTS: The mean safety margins (mm) of the experimental group were 7.59±4.30 (anterior), 8.56±4.69 (posterior), 5.25±3.01 (superior), 5.93±3.66 (inferior), 13.00±13.29 (medial), 5.78±2.64 (deep), and 6.67±3.06 (lateral). There were no differences in the safety margins between the two groups. CONCLUSION: Using guide wire under ultrasonography was not superior to the conventional method for partial glossectomy for having adequate resection margins.
Carcinoma, Squamous Cell
;
Glossectomy
;
Humans
;
Methods
;
Palpation
;
Prospective Studies
;
Recurrence
;
Tongue Neoplasms*
;
Tongue*
;
Ultrasonography*
7.Research on the Cun-Guan-Chi Pulse Detecting System.
Chinese Journal of Medical Instrumentation 2005;29(3):164-166
The paper introduces the designing concept of the Cun-Guan-Chi Pulse Detecting System and its basic principles, and structural features. The system comprises 3 independent pressure sensors with same design parameters. It provides a scientific and quantitative method of detecting the pulses, which tallies well with the diagnostic method of the traditional Chinese medicine.
Biosensing Techniques
;
instrumentation
;
methods
;
Equipment Design
;
Humans
;
Medicine, Chinese Traditional
;
Models, Biological
;
Palpation
;
instrumentation
;
methods
;
Pulse
;
Transducers, Pressure
8.The Efficacy of Carotid Tubercle as an Anatomical Landmark for Identification of Cervical Spinal Level in the Anterior Cervical Surgery: Comparison with Preoperative C-arm Fluoroscopy.
Jae Hyup LEE ; Ji Ho LEE ; Hyeong Seok LEE ; Do Yoon LEE ; Dong Oh LEE
Clinics in Orthopedic Surgery 2013;5(2):129-133
BACKGROUND: In cervical anterior approach, transverse skin incision is preferred due to cosmetic reasons. Precise skin incision is required to reach the surgery segment while minimizing soft tissue injury. Skin incision site is frequently identified using C-arm fluoroscopy or the carotid tubercle. Accordingly, this study was conducted to investigate the efficacy of skin incision using the carotid tubercle as a marker. METHODS: This study was retrospectively conducted on 114 patients who underwent anterior cervical surgery by the same surgeon from April 2004 to June 2012. The rate of the appropriate insertion of K-wire, which was inserted into the disc after anterior approach, into the surgery segment was compared between 62 patients where skin incision site was identified using C-arm fluoroscopy before skin incision and 52 patients where skin incision site was identified using carotid tubercle palpitation before surgery. RESULTS: The needle was shown to have been inserted into the planned site in 106 patients out of the total 114 patients. The appropriate insertion of the needle was shown in 59 patients of group I (95.2%) and in 47 patients of group II (90.4%). Although the success rate was higher in group I than group II, it was statistically insignificant. The success rate of one-segment surgery was shown to be 89.7% in group I and 82.6% in group II. Although the success rate was higher in group I than group II, it was statistically insignificant. The success rate of two-segment surgery was shown to be 100% in group I, and 96.4% in group II due to one case of the failure at C3-4 and C5-6. The success rate of three- and four-segment surgeries was shown to be 100% in both groups. CONCLUSIONS: The identification of skin incision site via carotid tubercle palpation was useful for surgeries involving two or more segments. Furthermore, it could be useful for one-segment surgery if surgical site is identified using vertebral body or soft tissues such as longus collis rather than insertion into the disc.
Adult
;
Anatomic Landmarks/anatomy & histology/radiography
;
Cervical Vertebrae/*anatomy & histology/radiography/*surgery
;
Female
;
Fluoroscopy/*methods
;
Humans
;
Male
;
Middle Aged
;
Palpation/*methods
;
Retrospective Studies
9."Palpation by imaging": magnetic resonance elastography.
Chinese Medical Sciences Journal 2006;21(4):281-286
Elasticity is an important physical property of human tissues. There is a tremendous difference in elasticity between normal and pathological tissues. Noninvasive evaluation of the elasticity of human tissues would be valuable for clinical practice. Magnetic resonance elastography (MRE) is a recently developed noninvasive imaging technique that can directly visualize and quantitatively measure tissue elasticity. This article reviewed the MRE technique and its current status.
Algorithms
;
Animals
;
Breast Neoplasms
;
diagnosis
;
Elasticity
;
Female
;
Humans
;
Image Processing, Computer-Assisted
;
Liver Cirrhosis
;
diagnosis
;
Magnetic Resonance Imaging
;
methods
;
Male
;
Palpation
;
Prostatic Neoplasms
;
diagnosis
10.A Clinical Study of the Femur Shaft Fracture in Children Treated by 90
Soo Kil KIM ; Keung Bae LEE ; Sae Jung OH ; Kye Seok YANG
The Journal of the Korean Orthopaedic Association 1989;24(3):761-767
Authors has analyzed 75 cases of the femoral shaft fractures in children, treated by 90-90 skeletal traction methods at Jung Ang Gil General Hospital during last six years, from March 1982 to April 1988. The results were as follows :1. The 90-90 Skeletal traction can be widely applicable to the age group ranging from 3 to 13 years, while other traction methods have a certain age limits. 2. Maintenance of initial reduction snd correction of angular and rotational deformity of femoral shaft fracture were easily achieved. In addition, later angular deformity can also be easily corrected. In angular deformity and instability type, the correction and maintenance of deformity and instability were helped by use of 2 cast slabs. 3. Follow-up observation as well as wound care of open fracture and associated soft tissue injury were relatively easy. 4. The period of immobilization necessory after fracture was not longer than the other methods of treatment, and during treatment, evaluation of bony alignment and union was possible by direct palpation and inspection with out the help of X-ray. 5. The limitation of knee motion as well as circulatory and neurogenic complication were not found. Therefore, these results revealed that 90-90 skeletal traction was the easy, safe and effective method in treatment of femoral shaft fractures in childeren.
Child
;
Clinical Study
;
Congenital Abnormalities
;
Femur
;
Follow-Up Studies
;
Fractures, Open
;
Hospitals, General
;
Humans
;
Immobilization
;
Knee
;
Methods
;
Palpation
;
Soft Tissue Injuries
;
Traction
;
Wounds and Injuries