1.Late Complication of a Silicone Implant Thirty Years after Orbital Fracture Reconstruction.
Chi An LEE ; Seok Joo KANG ; Ji Young YUN ; Hook SUN
Archives of Craniofacial Surgery 2017;18(2):137-140
Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 years earlier. A 50-year-old man was admitted to the emergency room for an exposed substance in the lower eyelid area of the left eye, which began as a palpable hard nodule a week earlier. The exposed material was considered to be implant used for previous surgery. Under general anesthesia, the implant and parts of the fibrous capsule tissue were removed. Several factors hinder the diagnosis of implant extrusions that occur a long period after the surgery. So, surgeons must be aware that complications with implants can still arise several decades following orbital fracture reconstruction, even without specific causes.
Anesthesia, General
;
Diagnosis
;
Diplopia
;
Emergency Service, Hospital
;
Eyelids
;
Hemorrhage
;
Humans
;
Middle Aged
;
Orbit*
;
Orbital Fractures*
;
Orbital Implants
;
Postoperative Complications
;
Silicon*
;
Silicones*
;
Surgeons
2.Late Complication of a Silicone Implant Thirty Years after Orbital Fracture Reconstruction.
Chi An LEE ; Seok Joo KANG ; Ji Young YUN ; Hook SUN
Archives of Craniofacial Surgery 2017;18(2):137-140
Alloplastic materials used for orbital fracture reconstruction can induce complications, such as infection, migration, extrusion, intraorbital hemorrhage, and residual diplopia. Silicone is one of the alloplastic materials that has been widely used for decades. The author reports a rare case of spontaneous extrusion of a silicone implant that was used for orbital fracture reconstruction 30 years earlier. A 50-year-old man was admitted to the emergency room for an exposed substance in the lower eyelid area of the left eye, which began as a palpable hard nodule a week earlier. The exposed material was considered to be implant used for previous surgery. Under general anesthesia, the implant and parts of the fibrous capsule tissue were removed. Several factors hinder the diagnosis of implant extrusions that occur a long period after the surgery. So, surgeons must be aware that complications with implants can still arise several decades following orbital fracture reconstruction, even without specific causes.
Anesthesia, General
;
Diagnosis
;
Diplopia
;
Emergency Service, Hospital
;
Eyelids
;
Hemorrhage
;
Humans
;
Middle Aged
;
Orbit*
;
Orbital Fractures*
;
Orbital Implants
;
Postoperative Complications
;
Silicon*
;
Silicones*
;
Surgeons
3.Hematic cyst formation after repair of blow-out fracture.
Shin Jeong KANG ; Il Hoon KWAK
Korean Journal of Ophthalmology 1996;10(1):60-62
Alloplastic implants are known to be inert for many years, though complications are infrequently reported many years after their insertion. We report the case of a patient who had undergone a blow-out fracture repair five years before the discovery of a hematic cyst. He had been free of symptoms for the first five years after his orbital floor repair but then developed pain on eyeball movement and persistent vertical diplopia, which finally led to surgical intervention. At surgery, a hematic cyst was found to have formed around the implanted silastic plate. When alloplastic material is used in orbital fracture repair, we should be alert for late complications which may occur many years after surgery.
Adult
;
Biocompatible Materials
;
*Blood
;
Bone Cysts/diagnosis/*etiology
;
Humans
;
Male
;
Orbital Diseases/diagnosis/*etiology
;
Orbital Fractures/diagnosis/*surgery
;
Postoperative Complications
;
Prostheses and Implants/*adverse effects
;
Reoperation
;
Silicone Elastomers/*adverse effects
;
Tomography, X-Ray Computed
4.A Case of Pseudo-Duane's Retraction Syndrome With Old Medial Orbital Wall Fracture.
Seung Hee LEE ; Jae Hyung LEE ; Soo Yoon LEE ; Sook Young KIM
Korean Journal of Ophthalmology 2009;23(4):329-331
We report a case of pseudo-Duane's retraction syndrome with entrapment of the medial rectus muscle in an old medial orbital wall fracture presenting identical clinical symptoms as Duane's retraction syndrome. A 15-year-old boy presented with persistent limited right eye movement since a young age. Examination showed marked limited abduction, mildly limited adduction, and globe retraction accompanied by narrowing of the palpebral fissure during attempted adduction in the right eye. He showed a right esotropia of 16 prism diopters and his head turned slightly to the right. A slight enophthalmos was noted in his right eye. A computed tomography scan demonstrated entrapment of the medial rectus muscle and surrounding tissues in an old medial orbital wall fracture. A forced duction test revealed a marked restriction of abduction in the right eye. A 5 mm recession of the right medial rectus muscle was performed. Postoperatively, the patient's head turn and esotropia in the primary position were successfully corrected, but there was still some limitations to his ocular movement. The importance of several tests such as the forced duction test and an imaging study should be emphasized in making a diagnosis for limitation of eye movement.
Adolescent
;
Diagnosis, Differential
;
Duane Retraction Syndrome/*diagnosis/etiology/physiopathology
;
Eye Movements/*physiology
;
Follow-Up Studies
;
Humans
;
Male
;
Oculomotor Muscles/*physiopathology/surgery
;
Ophthalmologic Surgical Procedures/methods
;
Orbital Fractures/*complications/diagnosis
;
Tomography, X-Ray Computed
5.Eyelid swelling and lucency in the skull radiograph.
Annals of the Academy of Medicine, Singapore 2009;38(10):928-928
Child
;
Edema
;
diagnostic imaging
;
etiology
;
Emphysema
;
diagnostic imaging
;
etiology
;
Ethmoid Bone
;
diagnostic imaging
;
injuries
;
Eyelid Diseases
;
diagnostic imaging
;
etiology
;
Humans
;
Male
;
Orbit
;
diagnostic imaging
;
Orbital Diseases
;
diagnosis
;
diagnostic imaging
;
pathology
;
Radiography
;
Skull
;
diagnostic imaging
;
pathology
;
Skull Fractures
;
complications
;
diagnostic imaging
6.Clinical outcome after orbital floor fracture reduction with special regard to patient's satisfaction.
Stefan HARTWIG ; Marie-Christine NISSEN ; Jan Oliver VOSS ; Christian DOLL ; Nicolai ADOLPHS ; Max HEILAND ; Jan Dirk RAGUSE
Chinese Journal of Traumatology 2019;22(3):155-160
PURPOSE:
Primary reconstruction via transconjunctival approach is a standardized treatment option for orbital floor fractures. The aim of this study was to compare the findings of specific ophthalmologic assessment with the patient's complaints after fracture reduction.
METHODS:
A retrospective medical chart analysis was performed on patients who had undergone transconjunctival orbital floor fracture reduction for fracture therapy with resorbable foil (ethisorb sheet or polydioxanone foil). A follow-up assessment including ophthalmological evaluation regarding visual acuity (eye chart projector), binocular visual field screening (Bagolini striated glasses test) and diplopia (cover test, Hess screen test) was conducted. Additionally, a questionnaire was performed to assess patients' satisfaction.
RESULTS:
A total of 53 patients with a mean follow-up of 23 months (ranging from 11 to 72) after surgical therapy were included. Diplopia was present preoperatively in 23 (43.4%) and reduced in follow-up examination (n = 12, 22.6%). Limitations in ocular motility reduced from 37.7% to 7.5%. The questionnaire about the patient's satisfaction revealed excellent outcomes in relation to the functional and esthetical parameters.
CONCLUSION
Transconjunctival approach is a safe approach for orbital fracture therapy. Postoperative diplopia is nearly never perceptible for the individual and differs to pathologic findings in the ophthalmic assessment.
Cohort Studies
;
Diplopia
;
diagnosis
;
etiology
;
Follow-Up Studies
;
Fracture Fixation
;
methods
;
Orbital Fractures
;
complications
;
physiopathology
;
psychology
;
surgery
;
Outcome Assessment (Health Care)
;
Patient Satisfaction
;
Polydioxanone
;
administration & dosage
;
Polyglycolic Acid
;
administration & dosage
;
Retrospective Studies
;
Surveys and Questionnaires
;
Treatment Outcome
;
Visual Acuity
;
Visual Fields