1.Development and Performance Test of Preamplifier and Amplifier for Gamma Probe.
Jong Doo LEE ; Hee Joung KIM ; Jung Kyun BONG ; Soo Il KWON
Korean Journal of Nuclear Medicine 1999;33(1):100-109
PURPOSE: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. MATERIALS and Methodes: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-rsistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Caberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047 (Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with 2"x2" NaI (T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with 1"x1"NaI (T1) crystal) were used for acquiring the energy spectra. RESULTS: Using PCB, energy resolutions or EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. CONCLUSION: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The RESULTS indicate that the PCB can be used in developing both counting and imaging gamma probe.
Connecticut
;
Ohio
;
Optics and Photonics
2.A comparison of density of Insight and Ektaspeed plus dental x-ray films using automatic and manual processing.
Korean Journal of Oral and Maxillofacial Radiology 2001;31(1):17-22
PURPOSE: To compare the film density of Insight dental X-ray film (Eastman Kodak Co., Rochester, NY, USA) with that of Ektaspeed Plus film (Eastman Kodak) under manual and automatic processing conditions. MATERIALS AND METHODS: Insight and Ektaspeed Plus films were exposed at three different exposure conditions with an aluminum step wedge on the films under the three different exposure times. The exposed films were processed by both manual and automatic ways. The Base plus fog density and the optical density made by exposing step wedge were calculated using a digital densitometer (model 07-443, Victoreen Inc, Cleveland, Ohio, USA). The optical densities of the Insight and Ektaspeed film versus thickness of alumimun wedge at the same exposure time were plotted on the graphs. Statistical analyses were applied for comparing the optical densities of the two films. RESULTS: The film density of both Insight films and Ektaspeed Plus films under automatic processing condition was significantly higher over the manual processing. The film density of Insight films was significantly higher than that of Ektaspeed Plus films on both automatic and manual processing conditions. CONCLUSION: The radiation exposure time can be reduced when using Insight over Ektaspeed Plus film. To take the full advantage of reducing exposure time, Insight film should be processed automatically.
Aluminum
;
Ohio
;
Radiography
;
Weather
;
X-Ray Film*
3.Introduction of legislation of disciplinary system for acupuncturists in various states in the United States: taking Ohio and other 11 states as examples.
Yu-Yang YANG ; Jia JIANG ; Jing REN ; Jing-Yuan LIU ; Yu-Chen FU ; Ni NI ; Bo-Yuan ZHANG
Chinese Acupuncture & Moxibustion 2022;42(8):923-926
With 12 representative states such as Ohio and Illinois as examples, the disciplinary system for acupuncturists in the United States is introduced. The disciplinary system mainly covers several aspects such as the subject of the implementation, the types of illegal acts, the form of disciplinary responsibility, and the hearing procedure. The acupuncture industry association has the responsibility of disciplinary action in most states. Corresponding disciplinary measures will be taken depending on the illegal activities of acupuncturists according to the types of illegal practice specified by each state. The hearing procedure provides procedural guarantee for the subsequent rights protection activities of acupuncturists.
Acupuncture
;
Acupuncture Therapy/methods*
;
Ohio
;
United States
4.A Case of Blastomycosis after Traveling around Non-Endemic Area.
Chang Gyun SEO ; Young Woo SEO ; Hun Pyo PARK ; Won Il CHOI ; Han Seung BEOM ; Kun Young KWON ; Soo Ji SUH ; Young June JEON
Tuberculosis and Respiratory Diseases 2005;58(6):619-623
Blastomycosis is a systemic pyogranulomatous disease that is caused by a thermally dimorphic fungus, Blastomyces dermatitidis. it's the disease is endemic in the south-eastern and south central states of the USA, which border the Mississippi and Ohio Rivers, the mid-western states and Canadian provinces bordering the Great Lakes as well as in a small area of New York and Canada adjacent to the St. Lawrence River.1 We encountered a case of blastomycosis, representing as a pulmonary manifestation after traveling around a non-endemic area and report it with a brief review of the relevant literature.
Blastomyces
;
Blastomycosis*
;
Canada
;
Fungi
;
Lakes
;
Mississippi
;
Ohio
;
Rivers
5.End - tidal Carbon Dioxide Measurements in the Pediatric Patients : A Comparison of End - tidal PCO2 Sampled from the Proximal and Distal Ends of Pediatric Uncuffed Tracheal Tube.
Hye Won LEE ; Po Sun KANG ; Hae Ja LIM ; Byung Kook CHAE ; Seong Ho CHANG ; Jung Soon SHIN
Korean Journal of Anesthesiology 1992;25(4):664-668
To determine the accuracy of end-tidal PCO2(PetCO2) measurement analysed with Ohmeda 5210 capnometer in the pediatric patients whose jung were ventilated with Ohio infant Circle Absorber and Ohio Ventilatior 7200, we compared PetCO2, measurements sampled from the proximal(PetCO2-p) and distal(PetCO2-d) ends of the tracheal tube to arterial PCO2(PaCO2) in 22 healthy pediatric patients between 6.8 to 18.5kg. The results were as follow: 1) Proximal PetCO2 and distal PetCO2 correlated with PaCO2(r=0.76%, SEE=2.79, r=0.70:SEE=3.01, respectively)(p<0.05). 2)Arterial to end-tidal PCO2 difference(delta(a-et)PCO2) was significantyly greater with distal(3.53+/-4.68 mmhg) than proximal(0.35+/-2.72 mmhg) sampling(p<0.05). 3) In subgroup of patients whose proximal to distal concentration of nitrous oxide difference was more than 2%, the delta(a-et)PCO2 using distal sampling(7.90+/-5.15 mmhg) was also significantly greater then it was using proximal sampling(-1.73+/-2.39 mmhg)(p<0.05).. We conclude that distal estimates of PetCO2-P can not provide accepatbale estimate of PaCO2 in healthy pediatric patients who are intubated with pediatric uncuffed tracheal tube.
Carbon Dioxide*
;
Carbon*
;
Humans
;
Infant
;
Nitrous Oxide
;
Ohio
6.A Economic Device of Gas Evacuator designed with Angle Stop Valve .
Jin Churl JOO ; Chung Hun YOON ; Kyu Suk SUH ; Kwang II SHIN ; Sang Ho JIN
Korean Journal of Anesthesiology 1978;11(2):169-171
Recent studies suggest possible deleterious effects of chronic exposure to certain common anesthetic agents. A simple and economic gas evacuator was designed with an angle stop valve of a water pipc system which was easily purchased from a hardware store. The device was installed as follows: 1) The pop-off valve assembly of an Ohio Unitrol anesthesia machine was removed and replaced with atail-piece of an angle stop valve with a new screw which was made to fit in place. 2) The disk of the angle stop valve was fixed in place with adhesive cement. 3) The tail nut and tail packing of the angle stop valve were replaced with the same caliver long vinyl hose, which eliminated overflow anesthetic gases from the anesthesia machine air vent system of the operating room. This device is inexpensive and simple to operate and is being used successfully in routine clinical practice.
Adhesives
;
Anesthesia
;
Anesthetics
;
Anesthetics, Inhalation
;
Nuts
;
Ohio
;
Operating Rooms
;
Tail
;
Water
7.Studies on Fluorine Compounds among the Air Pollutants.
Korean Journal of Preventive Medicine 1971;4(1):31-34
This study was conducted by the Dept. of Preventive Medicine, Kyung-Hee University, School of Medicine as a preliminay test for the effects of Fluorine Compounds to the Plants from April through August, 1971. Fluorine was measured with Zirconium-Alizarine method and the following findings could be obtained : 1. Most high densities (25.7pptm) was found around the industrial areas and lowest (19.3pptm) around residential sections in Seoul. 2. Average density of Fluorine in the atmosphere of Seoul City was 22.3 pptm which can damage such plants as Pine, Strawberry, Peach and Grapes. 3. Fluorine contests (22.3pptm) in Seoul area atmosphere of shows about 4 times more than that of Cincinnati, Ohio, U.S.A.
Air Pollutants*
;
Atmosphere
;
Fluorine Compounds*
;
Fluorine*
;
Fragaria
;
Humans
;
Ohio
;
Preventive Medicine
;
Prunus persica
;
Seoul
;
Vitis
8.Studies on Fluorine Compounds among the Air Pollutants.
Korean Journal of Preventive Medicine 1971;4(1):31-34
This study was conducted by the Dept. of Preventive Medicine, Kyung-Hee University, School of Medicine as a preliminay test for the effects of Fluorine Compounds to the Plants from April through August, 1971. Fluorine was measured with Zirconium-Alizarine method and the following findings could be obtained : 1. Most high densities (25.7pptm) was found around the industrial areas and lowest (19.3pptm) around residential sections in Seoul. 2. Average density of Fluorine in the atmosphere of Seoul City was 22.3 pptm which can damage such plants as Pine, Strawberry, Peach and Grapes. 3. Fluorine contests (22.3pptm) in Seoul area atmosphere of shows about 4 times more than that of Cincinnati, Ohio, U.S.A.
Air Pollutants*
;
Atmosphere
;
Fluorine Compounds*
;
Fluorine*
;
Fragaria
;
Humans
;
Ohio
;
Preventive Medicine
;
Prunus persica
;
Seoul
;
Vitis
9.A Comparative Study for Mesopic Contrast Sensitivity between Keratectomy(PRK) and Laser in Situ Keratomileusis(LASIK).
Jong Bae JUN ; Ji Eun LEE ; Jong Soo LEE
Journal of the Korean Ophthalmological Society 2004;45(10):1724-1730
PURPOSE: To compare the effect on visual performance of photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) with mesopic contrast sensitivity using CSV-1000S in excimer laser refractive surgery using the broad beam type and manual microkeratome. METHODS: Postoperative visual performance for 40 eyes undergoing PRK and 40 eyes undergoing LASIK was compared with mesopic contrast sensitivity at 1, 3, and 6 months postoperatively using the CSV 1000 (VectorVision, Ohio, USA). Eyes were divided into two groups: less than 6.0 D and over 6.25 D. Mesopic contrast sensitivity was performed with the patient's uncorrected-visual acuity of 20/20 or better under photopic condition. RESULTS: Under mesopic conditions a significant decrease in contrast sensitivity for the postoperative PRK and LASIK group was obtained at all spatial frequencies compared to the preoperative baseline (p<0.05). At 6 months postoperatively, LASIK decreased mesopic contrast sensitivity significantly more than PRK in myopia below -6.0 D, especially at the middle and high spatial frequencies of 6, 12, and 18 cpd (p<0.05). However, there were not statistically significant differences in mesopic contrast sensitivity between PRK and LASIK in myopia above -6.25 D (p>0.05). CONCLUSIONS: In the broad beam excimer laser, in cases of myopia with below 6.0 D, PRK seemed to have a more significant effect on mesopic contrast sensitivity than LASIK using manual microkeratome at postoperative 6 months.
Contrast Sensitivity*
;
Keratomileusis, Laser In Situ
;
Lasers, Excimer
;
Myopia
;
Ohio
;
Photorefractive Keratectomy
;
Refractive Surgical Procedures
10.Faculty-supervised measurements of the face and of mandibular movements on young adults.
Julian B WOELFEL ; Takayoshi IGARASHI ; Jin Keun DONG
The Journal of Advanced Prosthodontics 2014;6(6):483-490
PURPOSE: The purpose of this study was to determine the average facial proportions and mandibular movement capacity of 316 first-year dental students who carefully recorded them on each other. MATERIALS AND METHODS: This early exacting clinical experience was closely supervised by the authors in Columbus, Ohio during 1969-70. Five vertical and six horizontal distances were measured on each subject's face. An ala-tragus line and an occlusal line were drawn on the left side of the face to determine if these two lines were parallel. Measurements of mandibular movements involved maximum normal and hinge opening at the incisors and maximum amounts of right, left lateral and protrusive excursions of the mandible. RESULTS: The ala width and distance between the tips of upper right and left canine cusps averaged (35.2 mm and 34.8 mm) but with very large individual variations. The distance between ala to occlusal plane lines was 29.9 mm at the tragus and 31.3 mm near the ala. The angle between orbitale and ala-tragus averaged 13.6 degrees. CONCLUSION: The upper lip length was the most variable and the distance between the pupils was the most stable of the eleven facial measurements. The ala-tragus line and the occlusal plane lines were for all practical purposes parallel. Maximum jaw opening averaged 51.2 mm which was 3.0 times larger than maximal hinge opening of 17.2 mm. The maximum right plus left side jaw excursions (9.2 and 9.4 mm) totaled 18.6 mm, 2.3 times more than the 8.0 mm mean maximum forward protrusion.
Anthropometry
;
Dental Occlusion
;
Humans
;
Incisor
;
Jaw
;
Lip
;
Mandible
;
Ohio
;
Pupil
;
Students, Dental
;
Young Adult*