1.Dynamic three-dimensional shoulder kinematics in patients with massive rotator cuff tears: a comparison of patients with and without subscapularis tears
Yuji YAMADA ; Yoshihiro KAI ; Noriyuki KIDA ; Hitoshi KODA ; Minoru TAKESHIMA ; Kenji HOSHI ; Kazuyoshi GAMADA ; Toru MORIHARA
Clinics in Shoulder and Elbow 2022;25(4):265-273
Background:
Massive rotator cuff tears (MRCTs) with subscapularis (SSC) tears cause severe shoulder dysfunction. In the present study, the influence of SSC tears on three-dimensional (3D) shoulder kinematics during scapular plane abduction in patients with MRCTs was examined.
Methods:
This study included 15 patients who were divided into two groups: supraspinatus (SSP) and infraspinatus (ISP) tears with SSC tear (torn SSC group: 10 shoulders) or without SSC tear (intact SSC group: 5 shoulders). Single-plane fluoroscopic images during scapular plane elevation and computed tomography (CT)-derived 3D bone models were matched to the fluoroscopic images using two-dimensional (2D)/3D registration techniques. Changes in 3D kinematic results were compared.
Results:
The humeral head center at the beginning of arm elevation was significantly higher in the torn SSC group than in the intact SSC group (1.8±3.4 mm vs. −1.1±1.6 mm, p<0.05). In the torn SSC group, the center of the humeral head migrated superiorly, then significantly downward at 60° arm elevation (p<0.05). In the intact SSC group, significant difference was not observed in the superior-inferior translation of the humeral head between the elevation angles.
Conclusions
In cases of MRCTs with a torn SSC, the center of the humeral head showed a superior translation at the initial phase of scapular plane abduction followed by inferior translation. These findings indicate the SSC muscle plays an important role in determining the dynamic stability of the glenohumeral joint in a superior-inferior direction in patients with MRCTs.
2.In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium
Ginga SUZUKI ; Satoshi SHIMIZU ; Mana TORII ; Ai TOKUE ; Guo YING ; Masao YOSHINARI ; Noriyuki HOSHI ; Katsuhiko KIMOTO ; Hiromi MIURA ; Tohru HAYAKAWA ; Chikahiro OHKUBO
The Journal of Advanced Prosthodontics 2020;12(6):369-375
PURPOSE:
This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure.
MATERIALS AND METHODS:
The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test.
RESULTS:
Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/ rpm in machinability tests (P<.05).
CONCLUSION
Although the wear resistance and plaque adherence of MDFTi were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.
3.In vitro evaluation of a removable partial denture framework using multi-directionally forged titanium
Ginga SUZUKI ; Satoshi SHIMIZU ; Mana TORII ; Ai TOKUE ; Guo YING ; Masao YOSHINARI ; Noriyuki HOSHI ; Katsuhiko KIMOTO ; Hiromi MIURA ; Tohru HAYAKAWA ; Chikahiro OHKUBO
The Journal of Advanced Prosthodontics 2020;12(6):369-375
PURPOSE:
This study evaluated the availability of multi-directionally forged (MDF) titanium (Ti) as a component of removable partial dentures (RPDs). MDF-Ti remarkably improved the mechanical properties of RPDs due to its ultrafine-grained structure.
MATERIALS AND METHODS:
The wear resistance, plaque adhesion, and machinability of MDF-Ti were tested. As controls, commercially pure (CP) titanium was used for wear, plaque adhesion, and machinability tests. For wear resistance, the volume losses of the titanium teeth before and after wear tests were evaluated. Plaque adhesion was evaluated by the assay of Streptococcus mutans. In the machinability test, samples were cut and ground by a steel fissure bur and carborundum (SiC) point. An unpaired t-test was employed for the analysis of the significant differences between MDF-Ti and the control in the results for each test.
RESULTS:
Wear resistance and plaque adherence of MDF-Ti similar to those of CP-Ti (P>.05) were indicated. MDF-Ti exhibited significantly larger volume loss than CP-Ti in all conditions except 100/30,000 g/ rpm in machinability tests (P<.05).
CONCLUSION
Although the wear resistance and plaque adherence of MDFTi were comparable to those of controls, MDF-Ti showed better machinability than did CP-Ti. MDF-Ti could be used as a framework material for RPDs.
4.A case of autoimmune enteropathy with CTLA4 haploinsufficiency
Haruka MIYAZAKI ; Namiko HOSHI ; Michitaka KOHASHI ; Eri TOKUNAGA ; Yuna KU ; Haruka TAKENAKA ; Makoto OOI ; Nobuyuki YAMAMOTO ; Suguru UEMURA ; Noriyuki NISHIMURA ; Kazumoto IIJIMA ; Keisuke JIMBO ; Tsubasa OKANO ; Akihiro HOSHINO ; Kohsuke IMAI ; Hirokazu KANEGANE ; Ichiro KOBAYASHI ; Yuzo KODAMA
Intestinal Research 2022;20(1):144-149
Autoimmune enteropathy (AIE) is a rare disease, characterized by intractable diarrhea, villous atrophy of the small intestine, and the presence of circulating anti-enterocyte autoantibodies. Immune dysregulation, polyendocrinopathy, enteropathy, X-linked (IPEX) syndrome, and mutations in FOXP3, which is a master gene of regulatory T cells (Tregs), are major causes of AIE. Recent studies have demonstrated that mutations in other Treg-associated genes, such as CD25 and CTLA4, show an IPEX-like phenotype. We present the case of a 13-year-old girl with CTLA4 haploinsufficiency, suffering from recurrent immune thrombocytopenic purpura and intractable diarrhea. We detected an autoantibody to the AIE-related 75 kDa antigen (AIE-75), a hallmark of the IPEX syndrome, in her serum. She responded well to a medium dose of prednisolone and a controlled dose of 6-mercaptopurine (6-MP), even after the cessation of prednisolone administration. Serum levels of the soluble interleukin-2 receptor and immunoglobulin G (IgG) were useful in monitoring disease activity during 6-MP therapy. In conclusion, autoimmune-mediated mechanisms, similar to the IPEX syndrome, may be involved in the development of enteropathy in CTLA4 haploinsufficiency. Treatment with 6-MP and monitoring of disease activity using serum levels of soluble interleukin-2 receptor and IgG is suggested for such cases.