1.Study on the relationship between contents of poison in fishes and the levels of ocean pollutants in Zhoushan Fishery.
Jian-yue WANG ; Zhen-dong TONG ; Jian-bo YAN
Chinese Journal of Epidemiology 2005;26(1):18-21
OBJECTIVETo investigate the contents of poison in fishes in the Zhoushan Fishery and to analysis its relationship with the degree of ocean pollution.
METHODNine kinds of major fishes in the Zhoushan Fishery were sampled and tested. Canonical correlation was conducted to evaluate the correlation between contents of poison in fishes and the degree of ocean pollution.
RESULTSThe average contents of nickel among 9 kinds of fishes exceeded normal value by 1.177 times. No significantly statistical differences were found between the levels of poison contents in nine kinds of major fishes during 1997 to 2003 in the Zhoushan Fishery (the P values are all less than 0.05), except that the levels of cadmium and hydrargyrum in some fishes (the P values are all more than 0.05). The coefficient of fishes accumulated from different poisons ranged from 101.80 to 71 210.97. The canonical correlation coefficients of the variables of the contents of plumbum, arsenic and benzene hexachloride, chlorophennothane between fishes and ocean were 0.784 and 0.808 respectively. Positive correlation between them was shown (chi(2) = 20.994, P < 0.01; chi(2) = 38.017, P < 0.01).
CONCLUSIONThe sanitary quality indexes of all poisons which had been tested fell in the normal ranges except for nickel. The degrees of poisons accumulated among distinct fishes varied, showing the relationship of medium positive correlation between the poison contents of fishes and the degree of the ocean pollution.
Animals ; China ; Fishes ; Food Contamination ; analysis ; Metals, Heavy ; analysis ; Nickel ; analysis ; Seawater ; analysis ; Water Pollutants ; analysis
2.Genotypic and environmental variation in cadmium, chromium, arsenic, nickel, and lead concentrations in rice grains.
Wang-da CHENG ; Guo-ping ZHANG ; Hai-gen YAO ; Wei WU ; Min XU
Journal of Zhejiang University. Science. B 2006;7(7):565-571
Genotypic and environmental variation in Cd, Cr, As, Ni and Pb concentrations of grains, and the relationships between these heavy metals and Fe, Zn were investigated using 9 rice genotypes grown in 6 locations for two successive years. Significant genotypic variation was detected in the five heavy metal concentrations in grains, indicating the possibility to reduce the concentration of these heavy metals in grains through breeding approach. The environmental effect varied with metal, with Pb and Ni having greater variation than the other three metals. There was significant genotype-environment (location) interaction of the concentrations of all five heavy metals in grains, suggesting the importance of cultivar choice in producing rice with low heavy metal concentrations in grains for a given location. Correlation analysis showed that Cd and As, Cr and Ni, and As and Pb concentrations in rice grains were closely associated, and that Ni concentration in grains was negatively correlated with Zn concentration.
Arsenic
;
analysis
;
Cadmium
;
analysis
;
Chromium
;
analysis
;
Edible Grain
;
chemistry
;
genetics
;
Environment
;
Genetic Variation
;
genetics
;
Genotype
;
Lead
;
analysis
;
Metals, Heavy
;
analysis
;
Nickel
;
analysis
;
Oryza
;
chemistry
;
genetics
;
Soil Pollutants
;
analysis
3.The influences of inorganic elements in soil on the geolism of Atractylodes lancea.
Lan-ping GUO ; Lu-qi HUANG ; Yu-ning YAN
China Journal of Chinese Materia Medica 2002;27(4):245-250
OBJECTIVETo study the influence of inorganic elements in soil on the geolism of Atractylodes lancea.
METHODThe concentrations of 15 kinds of inorganic elements of regional A. lancea and their correspondingly soils were determined, and the data were analysed with the SPSS10.0 software.
RESULTThe mean concentration of Ni in geoherbs of A. lancea was 3 times higher than that in the non-geoherbs. The accumulation of Ca is high in geoberbs. There is no relationship between the concentrations of inorganic elements in A. lancea and those in their corresponding soil.
CONCLUSIONA. lancea adjusts the concentration of inorganic elements mainly by active absorption, and there are good relationship between the accumulation of Fe and Cr, Fe and Hg, Hg and Cr, As and Pb, Co and Sr.
Atractylodes ; chemistry ; Calcium ; analysis ; Chromium ; analysis ; Fluorocarbons ; analysis ; Geologic Sediments ; analysis ; Iron ; analysis ; Nickel ; analysis ; Plants, Medicinal ; chemistry ; Rhizome ; chemistry ; Soil ; analysis
4.Mechanical properties of thermodynamic nickel-titanium archwires in a simulated oral environment in vitro.
Xusheng FAN ; Zhihua LI ; Hui SHI ; Xiang LIU
West China Journal of Stomatology 2012;30(2):217-220
OBJECTIVEThis study was to investigate the mechanical properties of thermodynamic nickel-titanium (NiTi) archwires of different brands under controlled temperature and in artificial saliva to provide some reference for its clinical application.
METHODSUsing a modified partial dental arch bending system, four types of thermodynamic NiTi archwires were tested under controlled temperature (25, 33, 37, 60 degrees C) and in artificial saliva. An Instron Universal Testing Machine was used to apply 3 mm deflections of archwires in the lateral incisor area. The load-deflection curves were determined from the passive position to deflections of 3 mm. The following variables from unloading curves were calculated: Stiffness between 2.5 mm UDP (unloading deflection point) to 0.5 mm UDP after unloading. Any statistically significant differences in these variables for the different brands, temperature and moments levels were analyzed using one-way analysis of variance.
RESULTSUnloading values of four types thermodynamic nickel-titanium archwires increased with controlled temperature rising. The unloading stiffness of the same brand archwires were approximate at 25, 33, 37 degrees C, while their unloading stiffness increased obviously at 60 degrees C.
CONCLUSIONDifferent brands thermodynamic NiTi archwires demonstrated different mechanical behaviours, but all of them exhibited super elasticity and practical shape memory effect. The four thermodynamic NiTi archwires displayed temperature sensitivity at the four test temperatures.
Dental Alloys ; Dental Stress Analysis ; Elasticity ; Humans ; In Vitro Techniques ; Materials Testing ; Nickel ; Orthodontic Wires ; Temperature ; Titanium
5.CYTOTOXICITY OF DENTAL CAST BASE METAL ALLOYS ON HUMAN ORAL KERATINOCYTES.
Young Jin CHOI ; Moon Kyu CHUNG ; Jong In YOOK
The Journal of Korean Academy of Prosthodontics 1999;37(6):717-729
Although many studies on the cytotoxicity of the dental cast metal alloys and their components have been carried out, the results are rather conflicting because of the different type of cells used and the various experimental procedures taken. Recently, a number of scientists have claimed that it would be preferable to focus on the use of cells from relevant specific location of the human bodies. Consequently, the primary cultured oral keratinocyte derived from oral mucous along with nickel chloride and several of widely used dental cast base metal alloys(two-Ni-Cr alloys and one Co-Cr alloy)in domestic were selected for this study, from which 1) The amounts of released metal ions were determined using atomic absorption spectrometry, 2) The cytotoxicity of nickel chloride and dental cast base metal alloys was evaluated via MTT assay, and finally, 3) The amounts of released metal ions and the cytotoxicity of nickel chloride were correlated with the cytotoxicity of dental cast base metal alloys And, the results were summarized as follows ; 1. Nickel ion from Ni-Cr alloys and Cobalt ion from Co-Cr alloys resulted in maximum releasing rate during first 24 hours, followed by a decrease in releasing rate with time. Chromium ion were found to be minimal in all alloys. 2. In cytotoxic test, with 40muM, 80muM of nickel chloride, there were observed an increase in the relative cell number compared to control samples after 24 hours. With 160muM, there was found to be no difference in the relative cell number with control, except that 48 hour showed a increase in relative cell number. With 320muM, the relative cell number remained constant and decreased after 48 hours, and with 640muM, a continuing decrease in relative cell number was observed throughout test period. 3. The sensitivity of primary cultured oral epithelium to nickel was lower compared to the cells used in other studies. 4. CB-80 Soft and Regalloy showed no cytotoxicity to primary cultured oral epithelium and New crown resulted in a slight cytotoxicity. In conclusion, it was shown that the primary cultured oral keratinocytes could be applied successfully as testing cells in cytotoxicity test. Futhermore, the dental cast base metal alloys used in this study were found to be biocompatible.
Absorption
;
Alloys*
;
Cell Count
;
Chromium
;
Cobalt
;
Crowns
;
Epithelium
;
Human Body
;
Humans*
;
Ions
;
Keratinocytes*
;
Nickel
;
Spectrum Analysis
6.Safety performance of self-expandable NiTi alloy stent.
Zhiguo LI ; Wengang YAN ; Haiquan FENG
Journal of Biomedical Engineering 2020;37(2):334-339
In order to evaluate the safety performance of self-expandable NiTi alloy stents systematically, the dynamic safety factor drawn up by International Organization for Standardization, was used to quantitatively reflect the safety performance of stents. Based on the constitutive model of super-elastic memory alloy material in Abaqus and uniaxial tensile test data of NiTi alloy tube, finite element method and experiments on accelerated fatigue life were carried out to simulate the self-expansion process and the shape change process under the action of high and low blood pressure for three -type stents of 8×30 mm, 10×30 mm, 12×30 mm. By analyzing the changes of stress and strain of self-expanding NiTi alloy stent, the maximum stress and strain, stress concentration position, fatigue strength and possible failure modes were studied, thus the dynamic safety factor of stent was calculated. The results showed that the maximum stress and plastic strain of the stent increased with the increase of grip pressure, but the maximum stress and strain distribution area of the stent had no significant change, which were all concentrated in the inner arc between the support and the connector. The dynamic safety factors of the three stents were 1.31, 1.23 and 1.14, respectively, which indicates that the three stents have better safety and reliability, and can meet the fatigue life requirements of more than 10 years, and safety performance of the three stents decreases with the increase of stent's original diameter.
Alloys
;
Finite Element Analysis
;
Nickel
;
Reproducibility of Results
;
Self Expandable Metallic Stents
;
Stress, Mechanical
;
Titanium
7.Construction and mechanical analysis of finite element model for bending property of controlled memory wire nickel-titanium rotary file.
Hong Yu FU ; Fang Fang WANG ; Xiao Mei HOU
Journal of Peking University(Health Sciences) 2019;51(1):131-135
OBJECTIVE:
To construct a model for a controlled memory (CM) nickel-titanium (NiTi) file and another M-wire NiTi file with the same geometry by using finite element analysis. To evaluate the flexibility of a CM NiTi file by using three dimensional finite element method and to compare its mechanical responses with that M-wire NiTi.
METHODS:
Based on the reverse engineering, the 21 mm long, 25#/08 taper Hyflex NT NiTi file and Hyflex CM NiTi file were fixed by the cantilever bending model at a distance of 9.5 mm from the tip of the file. The mechanical tester's indenter was loaded/unloaded at a distance of 3 mm from the tip of the file. The maximum displacement was 3 mm, the load displacement curve was obtained. Subsequently, by using a micro-CT to scan (layer spacing of 8 μm) NiTi files, and ABAQUS (6.10) was introduced to construct a geometric model. Hyflex NT was considered as a shapememory alloy constitutive model, Hyflex CM was considered as a power-hardening plastic constitutive model, respectively. Comparing the load-displacement curve of cantilever bending in the three-dimensional finite element model with the load-displacement curve in the experiment.
RESULTS:
Two tetrahedral element models were constructed, the total number of nodes was 99 353 and the total number of cells was 63 744. When the loading displacement was 1 mm, the stress distribution of the cross section at 6.1 mm from the tip of the file was observed. The upper and lower surfaces were subjected to the maximum bending stress and entered the phase transformation yield stage. The finite element simulation could clearly show the deformation of the file. Various information such as deformation characteristics and stress distribution in the process were well fitted to the actual experimental curve.
CONCLUSION
The constitutive behavior of the material has a significant effect on the mechanical behavior of NiTi file. The finite element model established for the NiTi file of the CM wire can accurately capture the characteristics of various deformation processes of the NiTi root canal file, and it has a good fit with the actual experimental curve. The finite element model can be used for study on bending properties of CM wire.
Dental Alloys
;
Equipment Design
;
Finite Element Analysis
;
Materials Testing
;
Nickel
;
Root Canal Preparation
;
Stress, Mechanical
;
Titanium
8.Study on the relationship between PMI and the concentration of zincum and nickel in the vitreous humor of rabbit after death.
Zhi Qiang GONG ; Xiao Ming XU ; Xian Bin ZENG ; Yue Gang SUN ; Deng Wen WANG
Journal of Forensic Medicine 2001;17(3):129-131
OBJECTIVE:
To seek a exact method of estimating postmortem interval (PMI).
METHODS:
This study detected the concentration of zincum(Zn) and nickel(Ni) in vitreous humor of rabbit at hour 96 after death and explored the relationship between their concentration and PMI using a method ICP-MS.
RESULTS:
The concentration of Zn and Ni in vitreous humor of rabbit at hour 24 after death were related to PMI significantly; The formulae of the relationship between PMI and Zn concentrations is y = 0.1404x2 - 1.3351x + 3.8298 (within 24 h; R2 = 0.9202). The formula of the relationship between PMI and Ni concentrations is y = 0.0043x2 - 0.0596x + 0.2665(within 24 h; R2 = 0.9103).
CONCLUSION
The concentration of Zn and Ni in vitreous humor of rabbit may be a reference indicator to estimate early PMI.
Animals
;
Female
;
Forensic Medicine
;
Male
;
Nickel/analysis*
;
Postmortem Changes
;
Rabbits
;
Time Factors
;
Vitreous Body/chemistry*
;
Zinc/analysis*
9.The impact of NiO on microstructure and electrical property of solid oxide fuel cell anode.
Yan LI ; Zhong-yang LUO ; Chun-jiang YU ; Dan LUO ; Zhu-an XU ; Ke-fa CEN
Journal of Zhejiang University. Science. B 2005;6(11):1124-1129
Ni-Ce(0.8)Sm(0.2)O(1.9) (Ni-SDC) cermet was selected as anode material for reduced temperature (800 degrees C) solid oxide fuel cells in this study. The influence of NiO powder fabrication methods for Ni-SDC cermets on the electrode performance was investigated so that the result obtained can be applied to make high-quality anode. Three kinds of NiO powder were synthesized with a fourth kind being available in the market. Four types of anode precursors were fabricated with these NiO powders and Ce(0.8)Sm(0.2)O(1.9) (SDC), and then were reduced to anode wafers for sequencing measurement. The electrical conductivity of the anodes was measured and the effect of microstructure was investigated. It was found that the anode electrical conductivity depends strongly on the NiO powder morphologies, microstructure of the cermet anode and particle sizes, which are decided by NiO powder preparation technique. The highest electrical conductivity is obtained for anode cermets with NiO powder synthesized by NiCO(3).2Ni(OH)(2).4H(2)O or Ni(NO(3))(2).6H(2)O decomposition technique.
Electric Impedance
;
Electric Power Supplies
;
Electrochemistry
;
instrumentation
;
methods
;
Electrodes
;
Equipment Design
;
Equipment Failure Analysis
;
Nickel
;
chemistry
;
Powders
;
Surface Properties
10.Study on elastic limit and relevant enclasp force of non-precious metal casting clasp.
Hui CHENG ; Ming ZHENG ; Wei-qing WU ; Zong-yang HUANG ; Xiu-rong LI ; Xiang-rong CHENG
Chinese Journal of Stomatology 2004;39(3):227-229
OBJECTIVETo investigate the elastic limit and relevant enclasp force of the non-precious metal casting clasp.
METHODSCasting clasp samples of five cobalt-chromium alloys and one 18 - 8 nickel-chromium alloy were made from prefabricated clasp wax by invesing, casting, sandblasting, and ultrasonic cleaning. The process of casting clasp samples deflected by loading and returned by unloading was tested and electric signals were collected by an omnipotent material machine. The analog electric signal was converted to digital signal by an analog to digital converter and stored in a computer. The elastic limit and the relevant enclasp force were analyzed using a relative software.
RESULTSThe elastic limit and the relevant enclasp force of the casting clasp made from the 18 - 8 nickel-chromium alloy were smallest and those of the clasps made from the cobalt-chromium alloys in various brands were different. The range of the elastic limit of the cobalt-chromium alloy casting clasp with the length of 5.0 mm in undercut was 0.28 mm-0.33 mm and the relevant enclasp force was 14.42 g-19.28 g.
CONCLUSIONSIn clinic, we should select the suitable undercut deepness wherein the cobalt-chromium alloy casting clasps, according to different brands of the casting alloy, undercut length, undercut slope, and the clasp thickness.
Chromium Alloys ; Cobalt ; Dental Alloys ; Dental Clasps ; Dental Stress Analysis ; Denture, Partial, Removable ; Elasticity ; Humans ; Nickel ; chemistry ; Stress, Mechanical