1.The Efficacy and Prognostic Factors for Long Pulse Neodymium: Yttrium-Aluminum-Garnet Laser Treatment on Onychomycosis: A Pilot Study.
Sha LU ; Jing ZHANG ; Yuheng LIANG ; Xiqing LI ; Wenying CAI ; Liyan XI
Annals of Dermatology 2016;28(3):406-408
No abstract available.
Neodymium*
;
Onychomycosis*
;
Pilot Projects*
2.An Experimental Study on Renal Tissue Damage of Rabbit According to Neodymium-YAG Laser Energy.
Korean Journal of Urology 1985;26(6):585-589
Neodymium YAG (Nd-YAG) laser is a new instrument for the treatment of various urologic disorders where coagulation is necessary but still limited in cases. It avoids many of the side effects of electrocoagulations. Nd.YAG Iaser is a safe and effective modality, reducing blood loss, shortening operation time and preserving functional integrity on remaining renal tissue. In this experiment, to investigate the Nd-YAG Laser effect to renal tissue and the adaptation to renal surgery were aimed. We made the experimental study on renal tissue damage according to the change of irradiation time and power of NJ-YAG laser. The following results were obtained; After irradiation of Nd-YAG laser, renal tissue damage was noted on 30 Watt, 3 seconds and 5O Watt, 1 second, and the degree of renal tissue damage was increased with in creasing of laser power and time. A 2mm depth injured renal tissue was noted on 150-250 Joules, which coagulates the vessel with several mm diameter. Judging from the results of this experiment it may be believed that Nd-YAG laser can be adaptable to renal surgery in bleeding control without severe renal tissue damage.
Hemorrhage
;
Lasers, Solid-State
;
Neodymium
3.Anastomosis of Rabbit Uterine Horns using Neodymium: Yttrium Aluminum Garnet(Nd: YAG) Laser.
Joon Yeon JUN ; Sun An JUNG ; Young Hun SONG ; Young Me KOH ; Jang Heub KIM ; Jin Hong KIM ; Jin Woo LEE ; Soo Pyung KIM
Korean Journal of Obstetrics and Gynecology 1997;40(12):2809-2817
No abstract available.
Aluminum*
;
Animals
;
Horns*
;
Lasers, Solid-State
;
Neodymium*
;
Welding
;
Yttrium*
4.Comparison of Contrast Sensitivity with ACV (Visual Capacity Analyzer) in Different Types of Posterior Capsular Opacification.
Hyun Jin KIM ; Hyojin KIM ; So Hyun CHO ; Beom Jin CHO ; Ki Yong CHOI ; Kyu Hyung CHUNG ; Choun Ki JOO
Journal of the Korean Ophthalmological Society 2004;45(6):945-951
PURPOSE: To compare contrast sensitivity (CS) in type and degree of posterior capsule opacification (PCO) in pseudophakic eyes before and after neodymium: YAG capsulotomy. METHODS: Nine eyes with fibrosis-type PCO and 26 with Elschnig-pearl type PCO were examined for best corrected visual acuity (BCVA) and CS before and 1 week after capsulotomy. CS was tested with visual capacity analyzer (ACV) which uses a Landolt ring of 5 different spatial frequencies (SF) under two different conditions of day (100cd/m2) and night (30cd/m2). The patients were divided into two groups based on the BCVA before capsulotomy: Group A, 4 eyes and 18 eyes with below 0.63 in fibrosis-type and pearls-type PCO, respectively; Group B, 5 eyes and 8 eyes with above 0.63 in fibrosis-type and pearls-type PCO, respectively. RESULTS: The patients with PCO had worse BCVA and CS, but these were improved by Nd: YAG capsulotomy. This was not affected by the types and degrees of PCO. In the daytime condition, CS of B group was worse at all SF in patients with pearl-type PCO than in those with fibrosis-type PCO before capsulotomy, except 19 cpd (p<0.05). In the nighttime condition, CS in the two groups showed no difference at all SF (p>0.05). CONCLUSIONS: In the daytime condition, the patients with pearls-type PCO of relatively poor BCVA had lower CS than those with fibrosis-type PCO.
Capsule Opacification
;
Contrast Sensitivity*
;
Humans
;
Neodymium
;
Visual Acuity
5.Treatment of Laser Therapy-Induced Punctate Leukoderma Using a 308-nm Excimer Laser.
Han Mi JUNG ; Hyub KIM ; Ji Hae LEE ; Gyong Moon KIM ; Jung Min BAE
Annals of Dermatology 2017;29(5):630-632
Punctate leukoderma presents as numerous, distinct, round or oval depigmented spots. Recently, laser therapy-induced punctate leukoderma associated with various Q-switched laser and carbon dioxide laser have been reported. A 25-year-old man presented with numerous, discrete, round, confetti-like, depigmented macules on his left neck. He had undergone 3 sessions of 532-nm Q-switched Neodymium: Yttrium-Aluminum-Garnet laser treatment for café-au-lait macules three years ago. After the last laser treatment session, the punctate leukoderma had been developed. We started treatment with the 308-nm excimer laser twice a week. After 7 months of treatment duration, complete repigmentation was achieved without serious adverse effects. We recommend the 308-nm excimer laser as an effective treatment modality for laser therapy-induced punctate leukoderma.
Adult
;
Humans
;
Hypopigmentation
;
Lasers, Excimer*
;
Lasers, Gas
;
Neck
;
Neodymium
;
Vitiligo
6.Prospective Comparison of Dual Wavelength Long-Pulsed 755-nm Alexandrite/1,064-nm Neodymium:Yttrium-Aluminum-Garnet Laser versus 585-nm Pulsed Dye Laser Treatment for Rosacea.
Hyun Min SEO ; Jung In KIM ; Han Saem KIM ; Young Jun CHOI ; Won Serk KIM
Annals of Dermatology 2016;28(5):607-614
BACKGROUND: Rosacea treatments including oral/topical medications and laser therapy are numerous but unsatisfactory. OBJECTIVE: To compare the effectiveness of the dual wavelength long-pulsed 755-nm alexandrite/1,064-nm neodymium: yttrium-aluminum-garnet laser (LPAN) with that of 585-nm pulsed dye laser (PDL) for rosacea. METHODS: This was a randomized, single-blinded, comparative study. Full face received four consecutive monthly treatments with LPAN or PDL, followed-up for 6 months after the last treatment. Erythema index was measured by spectrophotometer, and digital photographs were evaluated by consultant dermatologists for physician's global assessment. Subjective satisfaction surveys and adverse effects were recorded. RESULTS: Forty-nine subjects with rosacea enrolled and 12 dropped out. There were no significant differences between LPAN and PDL in the mean reduction of the erythema index (p=0.812; 3.6% vs. 2.8%), improvement of physician's global assessment (p=1.000; 88.9% vs. 89.5%), and subject-rated treatment satisfaction (p=0.842; 77.8% vs. 84.2%). PDL showed more adverse effects including vesicles than LPAN (p=0.046; 26.3% vs. 0.0%). No other serious or permanent adverse events were observed in both treatments. CONCLUSION: Both LPAN and PDL may be effective and safe treatments for rosacea.
Consultants
;
Erythema
;
Humans
;
Laser Therapy
;
Lasers, Dye*
;
Neodymium
;
Prospective Studies*
;
Rosacea*
7.Intraocular Pressure Change Following Nd: YAG Laser Posterior Capsulotomy in After Cataract.
Han Joon PARK ; Jong Wook KIM ; Yong Sik KIM
Journal of the Korean Ophthalmological Society 2000;41(11):2338-2342
Intraocular pressures (IOP)were measured following Neodymium (Nd): YAG laser posterior capsulotomy in 51 pseudophakic eyes which had been treated with phacoemulsification and intraocular lens in the bag.Group 1 was no medical treated, group 2 was treated with 0.5%apraclonidine preoperatively, group 3 was treated with fluorometholone postoperatively, and group 4 was treated with 0.5%apraclonidine preoperatively and with fluorometholone postoperatively.IOP was measured preoperatively and 1, 3, 24 hours and 1 week postoperatively.Four eyes (7.8%)had greater than 5 mmHg elevation of IOP (1 eye in group 1, 3 eyes in group 3)and all of them decreased IOP to normal level within 3 hours.In summary, there was no or little IOP elevation without any medical treatment in eyes which had been treated with phacoemulsification and intraocular lens in the bag and had intact posterior lens capsule.
Cataract*
;
Fluorometholone
;
Intraocular Pressure*
;
Lasers, Solid-State*
;
Lenses, Intraocular
;
Neodymium
;
Phacoemulsification
;
Posterior Capsulotomy*
8.Comparison of Diode-Pumped, Frequency-Doubled Neodymium: YAG Laser and Blue-Green Argon Laser Iridotomy.
Journal of the Korean Ophthalmological Society 2001;42(10):1421-1426
PURPOSE: The solid-state, continuous-wave, frequency-doubled neodymium:yttrium-aluminum-garnet (Nd:YAG) laser pumped by diode laser has several advantages, including air cooling, higher electrical to optical efficiency ratios, and portability. The authors evaluated the use of the frequency-doubled Nd:YAG laser for peripheral iridotomy and compared with the argon blue-green laser. METHODS: Laser peripheral iridotomy was performed on 64 eyes of 47 patients with acute or chronic primary angle-closure glaucoma and narrow angles capable of closure. Thirty-one eyes of 25 patients were treated with frequency-doubled Nd:YAG laser and 33 eyes of 22 patients were treated with argon laser. Postoperative intraocular pressure, visual acuity, preoperative and postoperative medication, number of laser spots, and failure of patency were compared. RESULTS: Postlaser 1hr intraocular pressure elevation greater than 10 mmHg 1hr was seen in one (3.2%) of frequency-doubled Nd:YAG laser treated eyes and six (17.6%) of argon laser-treated eyes (p=0.055). The failure of patency was seen less often in frequency-doubled Nd:YAG laser than in argon laser (9.7% vs 27.3%, p=0.081). The number of laser spots was greater in frequency-doubled Nd:YAG laser than in argon laser (p=0.069). Preoperative, postoperative 1hr, 1day, 1mon, 3mons intraocular pressure, visual acuity, preoperative and postoperative antiglaucomatous medication, number of laser spots, and failure of patency were similar in the two groups. CONCLUSIONS: The above results suggest that the frequency-doubled Nd:YAG laser was at least as effective and appears to be as safe as the argon laser. However, laser iridotomy with frequency-doubled Nd:YAG laser may be more difficult than the argon laser.
Argon*
;
Glaucoma, Angle-Closure
;
Humans
;
Intraocular Pressure
;
Lasers, Semiconductor
;
Lasers, Solid-State*
;
Neodymium*
;
Visual Acuity
9.A study on the changes in attractive force of magnetic attachments for overdenture.
Han Wool LEEM ; In Ho CHO ; Jong Hyuk LEE ; Yu Sung CHOI
The Journal of Advanced Prosthodontics 2016;8(1):9-15
PURPOSE: Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients. MATERIALS AND METHODS: Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet. RESULTS: Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly. CONCLUSION: Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.
Adhesives
;
Corrosion
;
Denture, Overlay*
;
Effect Modifier, Epidemiologic
;
Humans
;
Neodymium
;
Prognosis
;
Steel
10.A STUDY ON THE PHYSICAL PROPERTIES AND BIOLOGICAL CHARACTERISTICS OF DENTAL MAGNETIC ATTACHMENTS.
Yong Sik LIM ; Yung Soo KIM ; Chang Whe KIM ; Yong Ho KIM
The Journal of Korean Academy of Prosthodontics 1999;37(1):1-22
In order to investigate various physical and biological properties of dental magnetic attachments studies on retentive characteristics, corrosion properties, cytotoxicity of different magnetic systems for dental applications were done. For the study of retentive characteristics changes of retentive force by increasing air gap, wear properties of various attachment systems and loss of magnetic force by heat treatment were measured. For the study of corrosion property of magnet covering metal electrochemical corrosion was done in artificial saliva and 0.9% NaCl solution between -1,000 mVSCE and +1,000 mVSCE. Anodic polarization curves are obtained about 6 types of samples and 2 types of solution. Corroded surfaces were examined with metallurgical microscope, scanning electron microscope and surface profilometer. For the study of cytotoxicity of magnetic attachment and its field cell growth and agar overlay test were done. The results of this study were as follows. 1.In Magnetic attachments using closed circuit retentive force at zero air gap was greater than magnets using open circuit, but decrease of retentive force by increasing air gap was also greater than open systems. 2.After 40,000 cycles of wear test all mechanical attachment resulted in varing degree of retention loss but in magnetic attachments no loss of retentive force was observed. 3.The magnetic attachment using Neodymium magnet showed early loss of retentive force about 200degrees C but attachment using Samarium magnet showed some resistance to heat treatment and complete retention loss was observed about 500degrees C. The keeper was not influenced by heat treatment in retention. 4.In electrochemical corrosion test Dyna magnetic attachment covering metal showed the highiest corrosion resistance and Shiner magnet covering metal showed the least corrosion resistance and examination of corroded surface with metallurgical microscope, scanning electron microscope and surface profilometer also showed same results with anodic polarization curves. 5.The result of cell culture tests on the magnet covered with metal showed least recognizable cytotoxicity.
Agar
;
Cell Culture Techniques
;
Corrosion
;
Cyprinidae
;
Hot Temperature
;
Neodymium
;
Population Characteristics*
;
Saliva, Artificial
;
Samarium