1.An Unexpected Vapor Leakage from Unlocked Vaporizer (Penlon Sigma Delta Anesthetic Vaporizer): A case report.
Seung Yun LEE ; Sung Ho SUH ; Jae Hoon CHO ; Jeong Ae LIM ; Kyoung Min LEE ; Nam Sik WOO
Korean Journal of Anesthesiology 2006;51(2):230-232
We present a case of an anesthetic gas leak through the valve of the Selectatec back bar during a surgical procedure. The Selectatec Vaporizing System is a quick-change system consisting of anesthetic vaporizers of the 'Tec models' of the Ohmeda machine that are seated on a compatibility manifold block located on the back bar of the anesthetic machine. In order to prevent a leak and a failure of vapor delivery, the "Tec models series" can only be turned 'on' when the locking lever is turned to the 'lock' position. However in this case, the control knob was rotated despite the back bar locking mechanism not being engaged, and a gas leak developed through the unlocked valves in Selectatec back bar. The Penlon Sigma Delta Anesthetic Vaporizer (sevoflurane) in a Datex-Ohmeda Aestiva/5 anesthesia machine can be turned 'on' when the locking lever is maintained at the 'unlock' position.
Anesthesia
;
Nebulizers and Vaporizers*
2.Is It Possible to Achieve Better Asthma Control by Using the Same Inhaler Device?.
Allergy, Asthma & Immunology Research 2012;4(4):169-170
No abstract available.
Asthma
;
Nebulizers and Vaporizers
3.An Unexpected Vapor Leakage from Locked Vaporizer.
Hyun Seok SEONG ; Sang Jin PARK ; In Seong KIM
Yeungnam University Journal of Medicine 2011;28(1):94-98
One of the most popular types of vaporizer mounting sytems is Selectatec, as it possesses a simple detachment mechanism. Detachable units can loosen between the vaporizer and anesthetic machine, which can cause vapor leakage. A locking system was subsequently developed to prevent this issue; however, we report a case of an unexpected vapor leakage from a locked vaporizer.
Anesthesia
;
Anesthetics
;
Inhalation
;
Nebulizers and Vaporizers
5.Blood Lead Concentration of Taxi Drivers in Taegu, Korea.
Kun SAKONG ; Pock Soo KANG ; Jong Hak CHUNG
Korean Journal of Preventive Medicine 1990;23(3):255-261
Taxi drivers are exposed to vehicular exhaust aerosols which are a major source of atmospheric lead pollution in Korea where lead additives are incorporated in petrol. To investigate the blood lead concentration, their correlation factors and influences on taxi drivers, samples were collected from 90 taxi drivers who were living in the Taegu City, during August, 1989. Blood lead concentration was estimated by the atomic absoption spectrophotometer (IL.551) equipped with flameless furnace atomizer (IL.665). The results were analyzed statistically and compared with control group were 26.34 +/- 6.53 microgram/dl and 20.77 +/- 4.80 microgram/dl respectively (p<0.01). No significant correlation was observed between the blood lead concentration of taxi drivers and driver career (r=0.093). There were no difference of statistical significance in the blood lead concentration of smokers and nonsmokers.
Aerosols
;
Daegu*
;
Korea*
;
Nebulizers and Vaporizers
7.Diagnosis and treatment of COPD.
Korean Journal of Medicine 2008;74(6):587-589
No abstract available.
Nebulizers and Vaporizers
;
Pulmonary Disease, Chronic Obstructive
;
Spirometry
8.Comparison of the Characteristics of 16 Commercial Nebulizer/Compressor Combinations Used in Korea.
Hyun Jung KIM ; Cho Ae LEE ; Eun Kyung HWANG ; Man Young HAN ; Uk Sung ANN ; Young Min CHO
Journal of the Korean Pediatric Society 2003;46(12):1235-1241
PURPOSE: We assessed the dynamic characteristics of 16 nebulizer/compressor combinations currently available in Korea. METHODS: The 16 nebulizer/compressor combinations(Pariboy Type 38/Long life, Pariboy Type N/ Long life, Pariboy Type N/Salter 8900, Pariboy Type N/LC, Devilbiss pulmoaid-LT/Hudson, Devilbiss pulmoaid/Hudson, Mesmed neb-300/Own, San-up 3040/Hudson, Midas(Basic)/Own, AirJolie 2/ Hudson, Thomas 1127/Salter 8900, Noel NE-2000/Salter 8900, Omron CX3/Hudson, Chang Woo CWN-100/Salter 8900, Voyage/Mefar, Chang Woo ASI-Pro/Medel jet pulse) were evaluated in terms of particle size and mass output. In addition, we determined the effects of nebulizer fill volume on mass output. RESULTS: Pariboy Type N/Long life has the highest respirable mass of 0.184 mg/min and Mesmed Neb-300/Own has the lowest 0.019 mg/min. Pariboy Type N/Long life has the highest mass output of 0.68 mg/min and the shortest mass median aerodynamic diameter(MMAD) of 3.76 m. All combinations other than Pariboy Type N/Long life produced a MMAD of over 5 m. MMAD over a 5 min nebulization ranged 3.76 to 9.83 m. There were no significant effects of fill volume on mass output. CONCLUSIONS: We concluded that there is a wide variation in performance of nebulizer/compressor combinations. The characteristics of nebulizer/compressor combinations should be considered in selecting products.
Korea*
;
Nebulizers and Vaporizers
;
Particle Size
;
Respiratory Therapy
9.Unexpected anesthetic leakage from a damaged O-ring on the Selectatec back bar: A case report.
Young Uk KIM ; Jimi OH ; Chan Hye PARK ; Byung Moon CHOI ; Dong Min JANG ; Ji Yeon BANG
Anesthesia and Pain Medicine 2017;12(2):183-186
The Selectatec mounting system was devised to provide easy and quick on-site fitting of various vaporizers for the anesthetic machine. However, a quick changing system for the vaporizer can also damage the O-ring due to friction between the vaporizer and the Selectatec back bar. We herein report a case of an unexpected anesthetic gas leakage from a damaged O-ring on the Selectatec back bar, which resulted from exchanging the vaporizers between two operations. In cases using the Datex Ohmeda machine, it is not easy to detect leakages from the vaporizers because of the location of the check valve near to the fresh gas outlet. This complicates the use of the positive pressure leakage test to detect a low pressure system leakage on the Selectatec back bar. We recommend the preanesthetic negative pressure or low-flow leakage test to detect a low pressure leakage when exchanging vaporizers on the Selectatec system.
Friction
;
Intraoperative Awareness
;
Nebulizers and Vaporizers
;
Ventilators, Mechanical
10.The Bronchodilatory Effect of Ipratropium Bromide on Bronchial Asthma.
Jae Hee AHN ; Tae Nyeon KIM ; Young Hyeun LEE ; Jae Chun CHUNG ; Hyun Woo LEE
Yeungnam University Journal of Medicine 1988;5(2):95-100
Ipratropium bromide (IP) is a new anticholinergic bronchodilator. To evaluate its effect on bronchial asthma which is still unknown in Korea, a double blind and randomized study was done on all patients of bronchial asthma who visit out-patients clinic of out department from June to September 197 and showed 75 to 100% of FEV1/FVC ratio on prebronchodilator spirometry (pre BD). The selected patients were given 2 puffs of Fenoterol (FE) or Ipratropium inhalator blindly and Spirometry. The repeated results are: 1. In both FE and IP groups, there was a significant bronchodilatory effect on 5 and 60 minutes after administration. 2. One 5 minutes, effect of FE was significantly greater than IP (FVC p<0.05, FEV1 p<0.01). 3. One 60 minutes, effect of IP was slightly less than FE but statistically non-significant. On the basis of above results, we concluded that onset of effect of IP is slower than FE, but its effect is significant and nearly comparable to FE.
Asthma*
;
Fenoterol
;
Humans
;
Ipratropium*
;
Korea
;
Nebulizers and Vaporizers
;
Outpatients
;
Spirometry