1.Perigraft Seroma after Endovascular Repair of the Abdominal Aortic Aneurysm
Naoki Toya ; Takao Ohki ; Makoto Sumi ; Hisano Toriumi ; Yuka Negishi
Japanese Journal of Cardiovascular Surgery 2003;32(5):285-287
A 75-year-old man underwent endovascular repair of the abdominal aortic aneurysm. The procedure was aorto-uni-femoral endograft and femorofemoral crossover bypass using PTFE graft. The postoperative course was satisfactory, but 4 years after operation, he was admitted complaining of abdominal fullness. CT scan showed significant increase of aneurysm diameter to 13cm without evidence of endoleak. Endograft replacement with a new Dacron graft was carried out. Intraoperative findings suggested perigraft seroma related to the use of PTFE, and there was no endoleak. The postoperative course was uneventful. Pathological finding of aneurysm showed a lack of hemocytes and thrombocytes.
2.Feasibility of Newly Developed Endoscopic Ultrasound with Zone Sonography Technology for Diagnosis of Pancreatic Diseases.
Yoshiki HIROOKA ; Akihiro ITOH ; Hiroki KAWASHIMA ; Eizaburo OHNO ; Yuya ITOH ; Yosuke NAKAMURA ; Takeshi HIRAMATSU ; Hiroyuki SUGIMOTO ; Hajime SUMI ; Daijiro HAYASHI ; Naoki OHMIYA ; Ryoji MIYAHARA ; Masanao NAKAMURA ; Kohei FUNASAKA ; Masatoshi ISHIGAMI ; Yoshiaki KATANO ; Hidemi GOTO
Gut and Liver 2013;7(4):486-491
BACKGROUND/AIMS: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography(TM) technology (ZST; Fujifilm Corp.). METHODS: Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts. The endoscopes used were EG-530UR2 and EG-530UT2 (Fujifilm Corp.). Two items were evaluated: visualization depth among four frequencies and image quality after automatic adjustment of sound speed (AASS), assessed using a 5-scale Likert scale by two endosonographers blinded to disease status. Because sound speed could be manually controlled, besides AASS, image quality at sound speeds of 1,440 and 1,600 m/sec were also assessed. RESULTS: In all cases, sufficient images were obtained in the range of 3 cm from the EUS probe. Judgments of image quality before AASS were 3.49+/-0.50, 3.65+/-0.48, respectively. After AASS, A and B scored 4.36+/-0.48 and 4.40+/-0.49 (p<0.0001). There were significant differences in the data before and after AASS and plus 60 m/sec, but no significant difference between the datasets were seen after AASS and at sound speeds manually set for minus 100 m/sec. CONCLUSIONS: EUS with ZST was shown to be feasible in this preliminary experiment. Further evaluation of this novel technology is necessary and awaited.
Endoscopes
;
Endosonography
;
Humans
;
Judgment
;
Mucins
;
Pancreatic Diseases
3.Nonspecific Inflammatory Aortic Regurgitation Diagnosed after Aortic Valve Replacement
Yosuke IKEDA ; Yuhei SAITOH ; Naoki SUMI ; Shingo ISHIGURO ; Takeshi SOEDA ; Yoshinobu NAKAMURA
Japanese Journal of Cardiovascular Surgery 2021;50(4):265-269
A case of clinical1y unsuspected nonspecific inflammatory aortic regurgitation is reported. A 69-year-old female patient underwent aortic valve replacement for aortic regurgitation. Pathological examination of resected aortic valve showed abscess formation and inflammatory granulation tissue in the non-coronary cusp. Therefore, we diagnosed nonspecific inflammatory aortic regurgitation. It is generally considered that the use of prednisolone for vasculitis syndrome is effective ; however, for nonspecific inflammatory aortic regurgitation its use has not been established. Prednisolone treatment could be an option for nonspecific inflammatory aortic regurgitation.