2.Synthesis of 6-18F-Py-AMD3465 and the microPET/CT imaging of this agent in mice bearing A549 tumor
Nan LIU ; Qiang YOU ; Yue FENG ; Qiang WAN ; Yue CHEN
Chinese Journal of Nuclear Medicine and Molecular Imaging 2016;36(2):122-126
Objective To synthesize 628F-Py-AMD3465,to investigate its biodistribution in mice and to perform the microPET/CT imaging on mice bearing human lung cancer cell (A549).Methods AMD3465 quaternary ammonium salt precursor was directly labeled with 18F,then 628F-Py-AMD3465 was synthesized through nucleophilic reaction,hydrolysis,neutralization and the product was purified using HPLC.The labeling yield and radiochemical purity were analyzed by HPLC.Fifteen Kunming mice were injected with 5.55 MBq of 628F-Py-AMD3465 and sacrificed at 5,20,40,60 and 120 min postinjection.The selected tissues were harvested and weighed,and the radioactivity in the tissues was measured by an automated γ-spectrometer.The %ID/g was calculated.MicroPET/CT studies were performed on A549-bearing mice after injecting 6-18F-Py-AMD3465 through vena caudal.Paired t test was used.Results 6-18F-Py-AMD3465 was successfully synthesized with the labeling yield of (9.0±2.0)%,the total synthesis time was about 60 min,and the radiochemical purity was more than 98%.Biodistribution studies showed that the radiouptake was higher in the kidneys and bladder of normal mice,which demonstrated that 6-18 F-Py-AMD3465 was mainly excreted through the kidneys.Biodistribution in A549-bearing mice was similar to that in normal mice.The tumor/muscle ratio at 40 min was 5.0,but the radiouptake of the tumor was still lower than that of the normal lung:(8.05±0.35) %ID/g vs (9.33±0.66) %ID/g;t=5.26,P<0.05.MicroPET/CT imaging showed that the high-uptake location of 6-18F-Py-AMD3465 in tumor-bearing mice was similar to the normal mice,and the tumor uptake reached the maximum level at 45 min post-injection (SUV 0.67).Conclusions 6-18F-Py-AMD3465 can be synthesized by a simple method.A lower uptake could be shown in the tumor compared to that in the lung and the tracer has limited diagnostic value for lung cancer.
3.Surgical treatment of the tumor disease in the lower trachea by using endoscopy.
Ding-qiang HUANG ; Jiang-nan HAN ; Ying LONG
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2012;47(10):866-867
Adult
;
Endoscopy
;
Female
;
Humans
;
Male
;
Middle Aged
;
Tracheal Neoplasms
;
surgery
;
Young Adult
5.Clinical features of adult patients with acute intestinal obstruction secondary to Meckel's diverticulum
Liang LIU ; Zhenli ZHOU ; Nan ZHANG ; Qiang YANG ; Tongtong WANG
Chinese Journal of Digestion 2011;31(2):91-94
Objective To analyze the clinical features of adult patients with acute intestinal obstruction secondary to Meckel's diverticulum and the experience in management of the disease.Methods The clinical data and pathological features of 9 patients with acute intestinal obstruction secondary to Meckel' s diverticulum were retrospectively analyzed. Results All patients were diagnosed with acute intestinal obstruction secondary to Meckel's diverticulum via abdominal cavity exploration and underwent surgical treatment. Before surgical treatment, 1 out of 9 patients was correctly diagnosed as acute intestinal obstruction secondary to Meckel's diverticulum, and the other 8patients were diagnosed as acute intestinal obstruction. Diverticulum was resected in 5 cases and the rest 4 cases received partial excision of small intestine including the diverticulum. Pathological examination showed that all patients had inflammatory changes in diverticulum. Some patients were complicated with mucosal erosion, small ulcers, bleeding or perforation. Forty-four percent (4/9) of diverticula contained ectopic tissue. All patients were cured. Conclusion Meckel's diverticulum is a rare cause of acute intestinal obstruction and preoperative diagnosis is difficult. Diverticulum,howere,is likelihood to develop strangulation or contains ectopic tissue, so that the surgical treatment should be performed early.
6.Impact of divided management on healthcare payment and income on standard community healthcare services
Yajun LIU ; Gang LIU ; Nan LI ; Zhilan FENG ; Qiang HU
Chinese Journal of Health Management 2010;04(5):290-293
Objective To explore the effect of separate management of income and expenditure (SMIE) on standard community healthcare services. Methods Health management records of 137 community health service ( CHS) institutions in Beijing during 2006 and 2009 were retrospectively analyzed. Paired t test was used to compare annual healthcare services at urban and rural areas before or after SMIE was adopted. Results The standard community healthcare services was reduced from 1 081 965. 53 to 971 793. 98 at urban areas and from 157 492. 23 to 149 305. 25 at rural areas (P >0. 05). Urban healthcare center-based standard services was decreased from 59. 94% to 52. 14% (P < 0. 05 ); while out-hospital services were increased from 13. 50% to 18. 88% (P<0. 05). In urban areas,standard services for women healthcare, chronic disease profiling, health education and information management were significantly increased (I <0. 05). However,Temporary observation and endemic disease prevention and treatment were the main job of rural healthcare. Conclusions SMIE in CHS institutions could accommodate to the need of health management, supporting policies should be further improved.
7.Study on calcific signs in pulmonary nodules based on pattern classification
Qiuping WANG ; Jun FENG ; Nan YU ; Yan LI ; Yongqian QIANG
Journal of Practical Radiology 2014;(10):1729-1732
Objective To study feasibility in extraction of calcific sign within pulmonary nodules with pattern classification.Meth-ods 49 cases with pulmonary nodules (benign in 16 and malignant in 33)confirmed by pathology or clinical follow-up were included in this study and all cases underwent chest CT examinations.CT images were interpreted double-blind by two associate chief radiolo-gists to draw a conclusion that there were any calcification within pulmonary nodules.Meanwhile,the calcifications in the regions of interest(ROI)on CT images were estimated with extraction of the sign of gray value,geometric and lung markings in ROI,and based on pattern classification algorithm at supporting vector machine(SVM).Results According to the results assessed by senior radiologists for classification within pulmonary nodules,the area under ROC curve was 0.95 which was extracted by automatic pat-tern classification algorithm,the extraction performance was stable(k=1),and was goodness fit with visual observation by doctors (k=0.939).Conclusion The ability of automatic pattern classification in detecting calcification within pulmonary nodules is about the same as that of visual assessment by senior doctors.
8.Comparison of different MR fat quantification methods at 3.0 T in a phantom study
Wei LIU ; Qiang DI ; Yunyao LAI ; Nan HONG ; Chuanxi HAO
Chinese Journal of Radiology 2014;48(12):1033-1037
Objective To investigate the value of MR imaging methods for the quantification of fat content in a customized lipid phantom at 3.0 T.Methods Eleven homogeneous fat-water phantoms (50 ml)with fat volume percentages from 0 to 100% were constructed with reference to Bernard's methods.Fat tractions of the lipid phantom were acquired using water selective saturation (WS),fat selective saturation (FS),in-and out-of-phase imaging (IOP),iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) gradient echo imaging and IDEAL Quant imaging methods on a 3.0 T MRI system.For statistical comparisons,paired-sample t test,Pearson correlation test,and Bland-Ahman maps were applied.Results Evaluated fat fractions acquired by WS,IDEAL Gradient echo imaging and IDEAL Quant were (49.6±28.8)%,(46.0±28.4)%,(51.0±32.0)%,the result has no significant difference with the true fat contents(t values were-0.186,-2.218,2.713;P values were 0.856,0.051,0.055).Evaluated fat fractions acquired by FS,corrected algorithm and IOP were (64.2±26.7)%,(58.9±31.9)% and (45.3±32.3)%,these three kinds of methods have significant difference with the true fat contents (t values were 5.168,4.273,-6.441;P<0.01).All the chemical shift imaging methods correlated with the true phantom model fat fractions,r values were 0.977(FS),0.978 (corrected algorithm),0.982 (WS),0.99 8(IOP),0.993 (IDEAL Gradient echo imaging),0.999 (IDEAL Quant) (all P<0.01).Each method's 95% confidence interval of the mean difference acquired by Bland-Altman map was WS (-14.7% to 13.8%),FS (-3.6% to 32.0%),corrected algorithm (-4.6% to 22.5%),IOP(-9.4% to 0.0%),IDEAL gradient echo imaging (-15.9% to 7.8%),IDEAL Quant(-2.0% to 4.0%).IDEAL Quant had the best correlation and confidence with the true fat fraction.Conclusions Chemical shift imaging methods (IOP,IDEAL Gradient echo imaging,IDEAL Quant) can acquire more accurate fat quantification results than chemical saturation imaging methods (FS,Corrected algorithm,WS) in a customized lipid phantom at 3.0 T.IDEAL Quant can acquire the best fat quantification result compared with the other imaging methods.
9.Hemocompatibility of polyoxymethylene used for bileaflet heart valve.
Liangliang WU ; Qiang SONG ; Tao LIU ; Li LIU ; Nan HUANG
Journal of Biomedical Engineering 2014;31(2):347-351
The possibility of polyoxymethylene (POM) as heart valve leaflet material was investigated by comparing the hemocompatibility with that of 316L stainless steel and low-temperature isotropic pyrolytic carbon (LTIC). Surface hydrophobicity was characterized by water contact angle measurement. Platelet adhesion, APTT/PT/TT and hemolysis rate tests were applied for evaluating hemocompatibility. The results showed that POM was hydrophobic and had a low hemolytic rate, adhesion amount and activation degree of platelets on POM surface were less than 316L stainless steel, and was similar to LTIC. This research pointed out potential application of POM as heart valve leaflets.
Biocompatible Materials
;
chemistry
;
Blood Platelets
;
Carbon
;
chemistry
;
Heart Valve Prosthesis
;
Heart Valves
;
Humans
;
Platelet Adhesiveness
;
Resins, Synthetic
;
chemistry
;
Stainless Steel
;
chemistry
10.Preliminary Applicaton of Placing Freka R Trelumina guided by DSA
Yuan TIAN ; Guokun AO ; Nan LI ; Qiang LI ; Qin HUANG
Chinese Medical Equipment Journal 2003;0(10):-
Objective To evaluate the initial clinical application value of placing the Freka R Trelumina guided DSA. Methods The Freka(R) Trelumina was placed guided by DSA in 10 patients with disease of digestive tract post operation complicated with stomal leak or/and stomal stegnosis or various kinds of patients with gastric emptying disorder. Results The Freka(R) Trelumina could be put 20 cm away from Treize anadesma guided by DSA. The achievement ratio was 90%. The putting time was 1 to 3 weeks. The localization of the Freka(R) Trelumina was well. The process of feeding was successfully. The effectiveness of decompression of stomach intestine was also good. Stomal leak healed up quickly. The appearance of gastric emptying disorder disappeared. Conclusion Placing the Freka(R) Trelumina guided by DSA is a simple, safe and reliable method for jejunum nourishment and gastrointestinal decompression.