1.In vivo experimental study of lumbar nucleus replacement with pectin/polyvinyl alcohol composite hydrogel.
Nü-zhao YAO ; Zhong-min ZHANG ; Da-di JIN
Chinese Journal of Surgery 2010;48(10):784-787
OBJECTIVETo evaluate the anti degenerative effect of pectin/polyvinyl alcohol composite (CoPP) hydrogel as artificial nucleus material in an animal model.
METHODSThirty-six New Zealand white rabbits were used to build animal models, the L₄₋₅ intervertebral discs were pierced with a Gauge#16 needle and polyvinyl alcohol (PVA) or CoPP implants were inserted into the holes. For comparative purposes, L₃₋₄ discs underwent sham treatment or control treatment in which the disc was pierced but no implant was inserted. All the discs were divided into four groups as follows: sham disc group, pierced disc group, PVA disc group and CoPP disc group. The discs were analyzed radiologically and histologically for degenerative changes at 1, 3 or 6 months after surgery.
RESULTSNone of the animals died from operative complications, such as paraplegia or infection before being killed. Macroscopically, none of the implants showed any signs of displacement at the time of harvest. The radiological analysis revealed that significantly less disc height loss was found with the PVA and CoPP replacement treatment than with the pierced treatment (P < 0.05). Changes in disc height after the replacement treatment were not significantly different from that after the sham treatment (P > 0.05). Histological degeneration of the replaced discs was delayed in comparison with that of the pierced discs (P < 0.05), but progressed with time, and PVA replacement showed faster disc degeneration than CoPP replacement.
CONCLUSIONSDegeneration of the anulus fibrosus after the CoPP prosthetic nucleus replacement treatment is delayed by preserving disc height and occupying the space of the nucleus pulposus, and it has great potential clinical application value.
Animals ; Female ; Implants, Experimental ; Intervertebral Disc ; pathology ; surgery ; Lumbar Vertebrae ; surgery ; Male ; Models, Animal ; Pectins ; therapeutic use ; Polyvinyl Alcohol ; therapeutic use ; Rabbits
2.Neotype spine exteral fixator development and clinical application of micor-invasive therapy for thoracolumbar fractures.
Xi-zheng SONG ; Xiang-dong WANG ; Wen-jun WANG ; Hong LIU ; Jian WEI ; Lu-shan WANG ; Nü-zhao YAO
China Journal of Orthopaedics and Traumatology 2008;21(9):698-699
Adolescent
;
Adult
;
Aged
;
Female
;
Follow-Up Studies
;
Fracture Fixation
;
instrumentation
;
Humans
;
Male
;
Middle Aged
;
Minimally Invasive Surgical Procedures
;
instrumentation
;
Postoperative Period
;
Radiography
;
Spinal Fractures
;
diagnostic imaging
;
pathology
;
physiopathology
;
surgery
;
Spinal Nerves
;
physiopathology
;
Spine
;
surgery
3.Association between maternal alcohol consumption and risk of congenital heart disease in offspring: a Meta analysis.
Qi LI ; Hua YAO ; Guan-Jun GU ; Zhao-Hui MA ; Deng-Ke WU ; Ge WU ; Yuan-Meng CHEN ; Tian-Nü LUO
Chinese Journal of Contemporary Pediatrics 2020;22(6):643-650
OBJECTIVE:
To study the association between maternal alcohol consumption and the risk of congenital heart disease (CHD) in offspring.
METHODS:
PubMed, Cochrane Library, Web of Science, Google Scholar, China Biology Medicine disc, Wanfang Database, CNKI Database, and Weipu Database were searched for the articles on the association between maternal alcohol consumption and congenital heart disease in offspring. These articles were published up to November 30, 2019. A random effects model or a fixed effects model was used for the pooled analysis of the results of each study, and then the pooled effective value and its 95%CI were calculated. A subgroup analysis was performed to explore heterogeneous regulators. Funnel plots and an Egger's test were used to assess publication bias.
RESULTS:
A total of 4 409 articles were searched, and 55 articles were finally included in this analysis, among which there were 6 cohort studies and 49 case-control studies. The Meta analysis showed heterogeneity across all studies (I=74%, P<0.01). The random effects model showed that maternal alcohol consumption was associated with CHD in offspring, with an OR of 1.18 (95%CI: 1.09-1.28). The Egger's test showed a certain degree of publication bias (P<0.05), and after adjustment, the pooled OR of CHD in offspring was 1.10 (95%CI: 1.01-1.21).
CONCLUSIONS
Maternal alcohol consumption may increase the risk of CHD in offspring.
Alcohol Drinking
;
Case-Control Studies
;
China
;
Cohort Studies
;
Heart Defects, Congenital
;
Humans
;
Risk Factors
4.Effect of new nucleus pulposus replacement on the flexibility motion and intradiscal pressure at the adjacent level
Nü zhao YAO ; Wen jun WANG ; Da di JIN
Journal of Medical Biomechanics 2011;26(1):E081-E086
Objective To evaluate the biomechanical stability of pectin/polyvinyl alcohol composite (CoPP)hydrogel and to assess the range of motion(ROM) and intradiscal pressure (IDP) changes at the above adjacent segment after the anterior implantation of CoPP hydrogel and cage. Method Six fresh cadaveric lumbar spine specimens(L3~L5)were biomechanically tested on the robotic testing machine. ROM at L3/4 and L4/5 and intradiscal pressure at L3/4 were measured. All measurements were made with initially intact and followed by both CoPP and cage implantations. Results At the implanted level (L4/5), the CoPP spine showed no significant change in the other five motion directions except left lateral bending motion compared with the intact spine (P>0.05), whereas the cage spine decreased significantly in all motion directions when compared with the intact spine or CoPP spine (P<0.05). At the above adjacent level of L3/4, the CoPP revealed a minor change in all motion directions except left lateral bending motion compared with the intact spine (P>0.05), whereas the ROM of cage spine significantly increased in all motion directions compared with the intact spine (P<0.05). The IDP of the CoPP spine did not increase under any condition compared with the intact spine (P>0.05). While the IDP of cage spine significantly increased in flexion/extension and left/right lateral bending compared with the intact spine or CoPP spine (P<0.05). There was no significant increase in axial rotation compared with the intact spine or CoPP spine (P>0.05). Conclusions The implantation of CoPP prosthetic nucleus can preserve the motion function at the operated level and maintain the lumbar stability. Compared with the lumbar fusion, the nucleus replacement has no significant effect on the ROM and IDP at adjacent level, which may decrease or avoid the adjacent segment degeneration.