1.A Study on Family Functioning and Anxiety in Family Caregiver System of Chronically ill patients.
Journal of Korean Academy of Adult Nursing 1998;10(2):289-301
The purpose of this study was to provide basic informations for developing family-focused nursing interventions for families with chronic illness. the results of this study were as follows. In family caregiver systems, spouses of chronically ill patients showed higher anxiety scores9t=4.71, P=.000) and higher scores of the perceived importance of family functioning(t=3.67, P=.000) than those of children of chronically ill patients. But spouses showed lower scores of the satisfaction of family functioning (t=2.92, P=.005) than those of children of chronically ill patients. For spouses of chronically ill patients, the correlation between the satisfaction of family functioning and anxiety turned out to be significant9r=-.518, P=.001). However for children the correlation between them was not statistically significant. Findings of this study suggest that families with chronic illness need family-focused nursing interventions to relieve their anxiety and to improve family functioning. In conclusion, the investigation about family functioning and anxiety provides useful information for family-focused nursing care, especially for spouses of chronically ill patients. This information will contribute to developing the support systems for family caregivers and the education programs that helps chronically ill patients.
Anxiety*
;
Caregivers*
;
Child
;
Chronic Disease*
;
Education
;
Humans
;
Nursing
;
Nursing Care
;
Spouses
2.Investigation of experimental acute ischemic myocardium with a microdialysis apparatus.
sung Dal PARK ; Song Myung KIM
The Korean Journal of Thoracic and Cardiovascular Surgery 1993;26(6):441-451
No abstract available.
Microdialysis*
;
Myocardium*
3.Submandibular Mass.
Myung Whun SUNG ; Dong Young KIM
Journal of the Korean Medical Association 1999;42(5):499-502
No abstract available.
4.The Effects of Aroma Foot Massage on the Anxiety, Pain and Sleep Satisfaction during Colonoscopy under Conscious Sedation.
Journal of Korean Academy of Community Health Nursing 2006;17(1):91-101
PURPOSE: This research is to know whether aroma foot massage has influence on the relief of anxiety and pain during colonoscopy under conscious sedation. METHOD: This research was designed as a quasi-experiment of non-equivalent control group pretest-posttest. Data were collected from April 1 2005 to August 30 2005. The subjects were divided into three groups (control group, foot massage group and aroma foot massage group) with 30 persons each. Anxiety was evaluated with Visual Analogue Scale (VAS), blood pressure and pulse. Pain response was measured with VAS and non-verbal pain behavior score. Sleep satisfaction was measured with a graphic rating scale. Data were analyzed through Chi-square test, t-test and repeated measure ANOVA. RESULTS: Systolic blood pressure, pulse, subjective anxiety and pain scores from the aroma foot massage group decreased significantly. Sleep satisfaction score of the aroma foot massage group increased significantly. Diastolic blood pressure from the aroma foot massage group did not decrease. CONCLUSION: The results show that aroma foot massage with refined oils can increase sleep satisfaction and decrease anxiety and pain during colonoscopy under conscious sedation.
Anxiety*
;
Blood Pressure
;
Colonoscopy*
;
Conscious Sedation*
;
Foot*
;
Humans
;
Massage*
;
Oils
5.Auditory brainstem response evoked by electrical stimulation (II): estimation of surviving spiral ganglion cells.
Myung Whun SUNG ; Chong Sun KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 1991;34(6):1154-1159
No abstract available.
Electric Stimulation*
;
Evoked Potentials, Auditory, Brain Stem*
;
Spiral Ganglion*
6.Clinical Study on Cast-Brace in Femoral Fractures
Young Min KIM ; Myung Ho KIM ; Dae Sung KIM
The Journal of the Korean Orthopaedic Association 1976;11(3):331-338
14 cases of femoral shaft fractures were treated with cast-brace for two years from June, 1974 to June, 1976 at the Department of Orthopedic Surgery, College of Medicine, Seoul National University Hospital. The results were as followings; 1. Of the 14 cases, eleven cases were male and three were female, and they were between 18 to 51 years of ages. 2. The fracture site was accounted that three of 14 cases were at the distal one third of the femur and the other eleven at the mid one third with four cases being comminuted. 3. 7 cases were treated with cast-brace initially, and the other 7 cases were secondarily treated, because of being complicated. 4. The average time of fracture healing was 14 weeks in the cases with cast-brace which is compared with 20 weeks of spica-cast control group in the same period. 5. One of 7 cases treated primarily developed shortening and angulation, which was corrected by open reduction and internal fixation.
Clinical Study
;
Female
;
Femoral Fractures
;
Femur
;
Fracture Healing
;
Humans
;
Male
;
Orthopedics
;
Seoul
7.A study on dose distribution of small irradiation field in the electron therapy.
Sung Kyu KIM ; Sei One SHIN ; Myung Se KIM
Yeungnam University Journal of Medicine 1991;8(2):114-120
In electron therapy, low melting point alloy is used for shaping of the field. Electron field shaping material affect the output factor as well as the collimator system. The output factors of electron beams for shaped fields from NELAC-1018 were measured using ionization chamber of Farmer type in water phantom. The output factors of electron beams depend on the incident energy, inherent collimator system and the size of shaped field. Obtained results were followings. 1. In the smaller applicator, output varied extremely according to extent of collimator opening. 2. The higher energy, the output is less varied according to treatment field at small field.
Alloys
;
Farmers
;
Freezing
;
Water
8.The Dosimetry of Radiosurgery using of Rando Phantom.
Sung Kyu KIM ; Sei One SHIN ; Myung Se KIM
Yeungnam University Journal of Medicine 1990;7(1):113-119
The stereotactic radiosurgery using ionizing radiation of high energy is a technique for exadicating intracranial small tumors, which are inaccessible or unsuitable for open surgical technique. For such a small field radiosurgery, TLD or film dosimetry is essential. The three dimensional dose planning of radiosurgery was performed with dose planning computer system (Therac 2300). The target dose distribution and its error according to patient position were discussed. And were measured of circular cone which specially designed in our Hospital. The position error of Rando Phantom compared with CT were 0.4 mm in the AP-LAT section and in the AP-VERT section, 1.0 mm in the AP-VERT 45°section. The ratio of accuracy of the gantry and couch rotation were 1.5 mm diameter for central axis of 18MeV linear accelerator. Our study suggested that radiosurgery of small field in out department will be appropriate for clinical application.
Computer Systems
;
Film Dosimetry
;
Humans
;
Particle Accelerators
;
Radiation, Ionizing
;
Radiosurgery*
9.How do the schizophrenic patients perceive others expressed emotion?.
Sung Gon KIM ; Chang Hee HONG ; Myung Jung KIM
Journal of Korean Neuropsychiatric Association 1992;31(3):545-555
No abstract available.
Expressed Emotion*
;
Humans
10.A study of dose distribution in postoperative radiotherapy in uterine cervical cancer.
Sei One SHIN ; Sung Kyu KIM ; Myung Se KIM
Yeungnam University Journal of Medicine 1991;8(1):166-177
Uterine cervical cancer is the most common malignancy in Korean women. In spite of recent development of early diagnostic and therapeutic modalities, about 40% of treated patient will develop relapse. So more aggressive local treatment such as more extensive surgery and higher radiation dose and administration of systemic chemotherapy will promote the curability but treatment related complications cannot be avoidable. We used 22 cases of early cervical cancer, treated with surgery and post-operative radiotherapy, clinical data of these patients were analyzed to determine relationship between clinical parameters and final outcome. Three out of 22 cases revealed relapse and one patient showed rectovaginal fistula and another patient showed small bowel obstruction and the other patient showed rectal obstruction. Two out of three recurrence were stage IIa and the other one case was stage Ib adenocarcinoma with lymphovascular involvement. Nineteen out of 22 cases were followed without remarkable side effect or treatment related complication or sequelae. We concluded that out treatment policy was safe and effective to eradicate high risk postoperative cervical cancer with acceptable side effects or complication.
Adenocarcinoma
;
Drug Therapy
;
Female
;
Humans
;
Radiotherapy*
;
Rectovaginal Fistula
;
Recurrence
;
Uterine Cervical Neoplasms*