1.Evaluating the Validity and Reliability of the Korean Version of the Scales for Outcomes in Parkinson’s Disease–Cognition
Jinse PARK ; Eungseok OH ; Seong-Beom KOH ; In-Uk SONG ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Yoon-Joong KIM ; Jin Whan CHO ; Hyeo-Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Jee-Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung KIM ; Jinyoung YOUN ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Joong-Seok KIM ; Ji-Young KIM
Journal of Movement Disorders 2024;17(3):328-332
Objective:
The Scales for Outcomes in Parkinson’s Disease–Cognition (SCOPA-Cog) was developed to assess cognition in patients with Parkinson’s disease (PD). In this study, we aimed to evaluate the validity and reliability of the Korean version of the SCOPACog (K-SCOPA-Cog).
Methods:
We enrolled 129 PD patients with movement disorders from 31 clinics in South Korea. The original version of the SCOPA-Cog was translated into Korean using the translation-retranslation method. The test–retest method with an intraclass correlation coefficient (ICC) and Cronbach’s alpha coefficient were used to assess reliability. Spearman’s rank correlation analysis with the Montreal Cognitive Assessment-Korean version (MOCA-K) and the Korean Mini-Mental State Examination (K-MMSE) were used to assess concurrent validity.
Results:
The Cronbach’s alpha coefficient was 0.797, and the ICC was 0.887. Spearman’s rank correlation analysis revealed a significant correlation with the K-MMSE and MOCA-K scores (r = 0.546 and r = 0.683, respectively).
Conclusion
Our results demonstrate that the K-SCOPA-Cog has good reliability and validity.
2.Stratification of rate of lymph node metastasis according to risk factors and oncologic outcomes in patients who underwent radical resection for rectal neuroendocrine tumors
Myung Jae JIN ; Sung Sil PARK ; Dong-Eun LEE ; Sung Chan PARK ; Dong Woon LEE ; Kiho YOU ; Hee Jin CHANG ; Chang Won HONG ; Dae Kyung SOHN ; Kyung Su HAN ; Bun KIM ; Byung Chang KIM ; Jae Hwan OH
Annals of Coloproctology 2023;39(6):467-473
Purpose:
Most predictive factors for lymph node metastasis in rectal neuroendocrine tumors (NETs) have been based on local and endoscopic resection. We aimed to evaluate the risk factors for lymph node metastasis in patients who underwent radical resection for rectal NETs and stratify the risk of lymph node metastasis.
Methods:
Sixty-four patients who underwent radical resection for rectal NETs between January 2001 and January 2018 were included. We investigated the risk factors of lymph node metastasis using clinicopathologic data. We also performed a risk stratification for lymph node metastases using the number of previously known risk factors. For oncologic outcomes, the 5-year overall survival and recurrence-free survival were evaluated in both groups.
Results:
Among the patients who underwent radical surgery, 32 (50.0%) had lymph node metastasis and 32 (50.0%) had non–lymph node metastasis. In the multivariable analysis, only the male sex was identified as a risk factor for lymph node metastasis (odds ratio, 3.695; 95% confidence interval, 1.128–12.105; P=0.031). When there were 2 or more known risk factors, the lymph node metastasis rate was significantly higher than when there were one or no risk factors (odds ratio, 3.667; 95% confidence interval, 1.023–13.143; P=0.046). There was also no statistical difference between the 2 groups in 5-year overall survival (P=0.431) and 5-year recurrence-free survival (P=0.144).
Conclusion
We found that the rate of lymph node metastasis increased significantly when the number of known risk factors is 2 or more.
3.Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease
Hye Jeon HWANG ; Hyunjong KIM ; Joon Beom SEO ; Jong Chul YE ; Gyutaek OH ; Sang Min LEE ; Ryoungwoo JANG ; Jihye YUN ; Namkug KIM ; Hee Jun PARK ; Ho Yun LEE ; Soon Ho YOON ; Kyung Eun SHIN ; Jae Wook LEE ; Woocheol KWON ; Joo Sung SUN ; Seulgi YOU ; Myung Hee CHUNG ; Bo Mi GIL ; Jae-Kwang LIM ; Youkyung LEE ; Su Jin HONG ; Yo Won CHOI
Korean Journal of Radiology 2023;24(8):807-820
Objective:
To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software.
Materials and Methods:
This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1–7 according to acquisition conditions. CT images in groups 2–7 were converted into the target CT sty le (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system.
Results:
Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2–7 improved after CT conversion (original vs. converted: 0.63vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists’ scores were significantly higher (P < 0.001) and less variable on converted CT.
Conclusion
CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.
4.Validation of the Korean Version of the Questionnaire for Impulsive-Compulsive Disorders in Parkinson's Disease Rating Scale
Ji-Hyun CHOI ; Jee-Young LEE ; Jin Whan CHO ; Seong-Beom KO ; Tae-Beom AHN ; Sang Jin KIM ; Sang-Myung CHEON ; Joong-Seok KIM ; Yoon-Joong KIM ; Hyeo-Il MA ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong-Min KIM ; In-Uk SONG ; Han-Joon KIM ; Young-Hee SUNG ; Do Young KWON ; Jae-Hyeok LEE ; Ji-Young KIM ; Ji Sun KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi-Jung Kim KIM ; Jinyoung YOUN ; Ji Seon Kim KIM ; Eung Seok OH ; Hui-Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum-Yil KWON ; Hyung-Eun PARK ; Su-Yun LEE ; Younsoo KIM ; Hee-Tae KIM ; Mee Young PARK
Journal of Clinical Neurology 2020;16(2):245-253
Background:
and PurposeImpulse-control disorder is an important nonmotor symptom of Parkinson's disease (PD) that can lead to financial and social problems, and be related to a poor quality of life. A nationwide multicenter prospective study was performed with the aim of validating the Korean Version of the Questionnaire for Impulsive-Compulsive Disorders in Parkinson's Disease Rating Scale (K-QUIP-RS).
Methods:
The K-QUIP-RS was constructed using forward and backward translation, and pretesting of the prefinal version. PD patients on stable medical condition were recruited from 27 movement-disorder clinics. Participants were assessed using the K-QUIP-RS and evaluated for parkinsonian motor and nonmotor statuses and for PD-related quality of life using a predefined evaluation battery. The test–retest reliability of the K-QUIP-RS was assessed over an interval of 10–14 days, and correlations between the KQUIP-RS and other clinical scales were analyzed.
Results:
This study enrolled 136 patients. The internal consistency of the K-QUIP-RS was indicated by a Cronbach's α coefficient of 0.846, as was the test–retest reliability by a Guttman split-half coefficient of 0.808. The total K-QUIP-RS score was positively correlated with the scores for depression and motivation items on the Unified PD Rating Scale (UPDRS), Montgomery-Asberg Depression Scale, and Rapid-Eye-Movement Sleep-Behavior-Disorders Questionnaire. The total K-QUIP-RS score was also correlated with the scores on part II of the UPDRS and the PD Quality of Life-39 questionnaire, and the dopaminergic medication dose.
Conclusions
The K-QUIP-RS appears to be a reliable assessment tool for impulse-control and related behavioral disturbances in the Korean PD population.
5.Subtypes of Sleep Disturbance in Parkinson's Disease Based on the Cross-Culturally Validated Korean Version of Parkinson's Disease Sleep Scale-2
Hui Jun YANG ; Han Joon KIM ; Seong Beom KOH ; Joong Seok KIM ; Tae Beom AHN ; Sang Myung CHEON ; Jin Whan CHO ; Yoon Joong KIM ; Hyeo Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong Min KIM ; In Uk SONG ; Ji Young KIM ; Young Hee SUNG ; Do Young KWON ; Jae Hyeok LEE ; Jee Young LEE ; Ji Seon KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Yong HONG ; Mi Jung KIM ; Jinyoung YOUN ; Ji Sun KIM ; Eung Seok OH ; Won Tae YOON ; Sooyeoun YOU ; Kyum Yil KWON ; Hyung Eun PARK ; Su Yun LEE ; Younsoo KIM ; Hee Tae KIM ; Sang Jin KIM
Journal of Clinical Neurology 2020;16(1):66-74
BACKGROUND:
AND PURPOSE: This study aimed to determine the clinimetric properties of the Korean version of Parkinson's Disease Sleep Scale-2 (K-PDSS-2) and whether distinct subtypes of sleep disturbance can be empirically identified in patients with Parkinson's disease (PD) using the cross-culturally validated K-PDSS-2.
METHODS:
The internal consistency, test–retest reliability, scale precision, and convergent validity of K-PDSS-2 were assessed in a nationwide, multicenter study of 122 patients with PD. Latent class analysis (LCA) was used to derive subgroups of patients who experienced similar patterns of sleep-related problems and nocturnal disabilities.
RESULTS:
The total K-PDSS-2 score was 11.67±9.87 (mean±standard deviation) at baseline and 12.61±11.17 at the retest. Cronbach's α coefficients of the total K-PDSS-2 scores at baseline and follow-up were 0.851 and 0.880, respectively. The intraclass correlation coefficients over the 2-week study period ranged from 0.672 to 0.848. The total K-PDSS-2 score was strongly correlated with health-related quality of life measures and other corresponding nonmotor scales. LCA revealed three distinct subtypes of sleep disturbance in the study patients: “less-troubled sleepers,â€â€œPD-related nocturnal difficulties,†and “disturbed sleepers.â€
CONCLUSIONS
K-PDSS-2 showed good clinimetric attributes in accordance with previous studies that employed the original version of the PDSS-2, therefore confirming the cross-cultural usefulness of the scale. This study has further documented the first application of an LCA approach for identifying subtypes of sleep disturbance in patients with PD.
6.Safety and Efficacy of the Endeavor Resolute® Stent in Patients with Multivessel Disease: The HEART (Honam EndeAvor ResoluTe) Prospective, Multicenter Trial
Doo Sun SIM ; Myung Ho JEONG ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Keun Ho PARK ; Sun Ho HWANG ; Dong Goo KANG ; Seung Uk LEE ; Joon Woo KIM ; Jong Pil PARK ; Jay Young RHEW ; Sang Rok LEE ; Jei Keon CHAE ; Kyeong Ho YUN ; Seok Kyu OH ; Won You KANG ; Su Hyun KIM ; Jang Hyun CHO
Chonnam Medical Journal 2018;54(1):55-62
The Endeavor Resolute® (ER) is a zotarolimus-eluting stent (ZES) with a biocompatible BioLinx polymer. This study prospectively compared the clinical outcomes of 2 versions of ZES, ER and Endeavor Sprint® (ES), in patients with multivessel disease. A total of 488 patients who underwent multivessel percutaneous coronary intervention (PCI) were divided into 2 groups the ER group (n=288) and the ES group (n=200). The primary endpoint was a composite of major adverse cardiac events (MACE) consisting of death, myocardial infarction, and target vessel revascularization after 12 months. In all patients, the prevalence of diabetes was higher in the ER group (42.7% vs. 31.0%, p=0.009). The rate of post-PCI Thrombolysis in Myocardial Infarction flow grade 3 was higher in the ER group (100.0% vs. 98.0%, p=0.028). There were no between-group differences in the in-hospital, 1-month and 12-month clinical outcomes. In the propensity score matched cohort (n=200 in each group), no differences were observed in the baseline and procedural characteristics. There were no statistical differences in the rates of in-hospital, 1-month and 12-month events (12-month MACE in the ER and ES groups: 6.0% vs. 3.5%, p=0.240, respectively). The safety and efficacy of both versions of ZES were comparable in patients with multivessel disease during a 12-month clinical follow-up.
Cohort Studies
;
Coronary Artery Disease
;
Drug-Eluting Stents
;
Follow-Up Studies
;
Heart
;
Humans
;
Multicenter Studies as Topic
;
Myocardial Infarction
;
Percutaneous Coronary Intervention
;
Polymers
;
Prevalence
;
Propensity Score
;
Prospective Studies
;
Stents
7.A Child with Mycoplasma pneumoniae-related Encephalitis Presenting as Hyperactive Behavior Change.
Hyo Bin KIM ; So Myung KONG ; Jin Sung PARK ; Su Jeong YOU
Journal of the Korean Child Neurology Society 2018;26(2):119-122
Mycoplasma pneumoniae is a respiratory pathogen responsible for various upper and lower respiratory tract diseases. This also induces extra-pulmonary manifestations, with encephalitis being the most frequent and critical manifestation in pediatric populations. This report describes an 8-year-old boy who presented with repetitive motions in both hands, agitation, muttering and increased appetite after seizure. He had started treatment with antibiotics for M. pneumoniae infection 14 days prior to this event. Electroencephalography (EEG) showed slow and disorganized background rhythms and polymorphic slowing on both frontal areas, whereas brain magnetic resonance imaging was normal. He was diagnosed with M. pneumoniae-related encephalitis and treated with intravenous immunoglobulin (500 mg/kg/day for 4 days). After 3 days, his impulsive behaviors disappeared and, after 4 days, his EEG became normal. Abrupt hyperactive behavior in children may be a sign of M. pneumoniae-related encephalitis.
Anti-Bacterial Agents
;
Appetite
;
Brain
;
Child*
;
Dihydroergotamine
;
Electroencephalography
;
Encephalitis*
;
Hand
;
Humans
;
Immunoglobulins
;
Impulsive Behavior
;
Magnetic Resonance Imaging
;
Male
;
Mycoplasma pneumoniae
;
Mycoplasma*
;
Pneumonia
;
Pneumonia, Mycoplasma
;
Respiratory Tract Diseases
;
Seizures
8.Validation of the Korean Version of the Scales for Outcomes in Parkinson's Disease-Sleep
Young Hee SUNG ; Hee Jin KIM ; Seong Beom KOH ; Joong Seok KIM ; Sang Jin KIM ; Sang Myung CHEON ; Jin Whan CHO ; Yoon Joong KIM ; Hyeo Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong Min KIM ; In Uk SONG ; Han Joon KIM ; Ji Young KIM ; Do Young KWON ; Jae Hyeok LEE ; Jee Young LEE ; Ji Seon KIM ; Ji Young YUN ; Jin Yong HONG ; Mi Jung KIM ; Jinyoung YOUN ; Ji Sun KIM ; Eung Seok OH ; Hui Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum Yil KWON ; Hyung Eun PARK ; Su Yun LEE ; Younsoo KIM ; Hee Tae KIM ; Tae Beom AHN
Journal of Korean Medical Science 2018;33(2):e14-
BACKGROUND: Sleep problems commonly occur in patients with Parkinson's disease (PD), and are associated with a lower quality of life. The aim of the current study was to translate the English version of the Scales for Outcomes in Parkinson's Disease-Sleep (SCOPA-S) into the Korean version of SCOPA-S (K-SCOPA-S), and to evaluate its reliability and validity for use by Korean-speaking patients with PD. METHODS: In total, 136 patients with PD from 27 movement disorder centres of university-affiliated hospitals in Korea were enrolled in this study. They were assessed using SCOPA, Hoehn and Yahr Scale (HYS), Unified Parkinson's Disease Rating Scale (UPDRS), Parkinson's Disease Sleep Scale 2nd version (PDSS-2), Non-motor Symptoms Scale (NMSS), Montgomery Asberg Depression Scale (MADS), 39-item Parkinson's Disease Questionnaire (PDQ39), Neurogenic Orthostatic Hypotension Questionnaire (NOHQ), and Rapid Eye Movement Sleep Behaviour Disorder Questionnaire (RBDQ). The test-retest reliability was assessed over a time interval of 10–14 days. RESULTS: The internal consistency (Cronbach's α-coefficients) of K-SCOPA-S was 0.88 for nighttime sleep (NS) and 0.75 for daytime sleepiness (DS). Test-retest reliability was 0.88 and 0.85 for the NS and DS, respectively. There was a moderate correlation between the NS sub-score and PDSS-2 total score. The NS and DS sub-scores of K-SCOPA-S were correlated with motor scale such as HYS, and non-motor scales such as UPDRS I, UPDRS II, MADS, NMSS, PDQ39, and NOHQ while the DS sub-score was with RBDQ. CONCLUSION: The K-SCOPA-S exhibited good reliability and validity for the assessment of sleep problems in the Korean patients with PD.
Depression
;
Humans
;
Hypotension, Orthostatic
;
Korea
;
Movement Disorders
;
Parkinson Disease
;
Quality of Life
;
Reproducibility of Results
;
Sleep, REM
;
Weights and Measures
9.Acquired Hemophilia A Combined with Systemic Lupus Erythematosus: A Case Report and Literature Review.
Juyoung YOU ; Hojae KIM ; Jin Su PARK ; Myung Hee CHANG ; Chan Hee LEE
Journal of Rheumatic Diseases 2017;24(5):309-312
Acquired hemophilia A (AHA) is a rare hemorrhagic disorder caused by autoantibodies against factor VIII (FVIII). An 80-year-old woman presented multiple bruises on her upper and lower extremities, along with gross hematuria. Extensive ecchymosis and swelling were observed on the buttocks. She had anemia and normal platelet count. The initial coagulation results showed prolonged activated partial thromboplastin time (aPTT, 68.5 seconds) and normal prothrombin time. According to the mixing test, we observed a decreased FVIII activity (2%), increased factor VIII inhibitor (FVIII-I) titer (74.4 BU), and negative lupus anticoagulant. AHA was diagnosed based on late onset bleeding and increased FVIII-I titer. Additionally, she met the criteria for systemic lupus erythematosus (oral ulcer, photosensitivity, renal disorder, and positivity for antinuclear and anti-β2-glycoprotein-I antibodies). She was started on oral prednisolone for FVIII-I eradication. Post-treatment, her bleeding tendency, aPTT (47.3 seconds), and FVIII-I titer decreased (1.24 BU), and FVIII activity increased (10%).
Aged, 80 and over
;
Anemia
;
Autoantibodies
;
Buttocks
;
Contusions
;
Ecchymosis
;
Factor VIII
;
Female
;
Hematuria
;
Hemophilia A*
;
Hemorrhage
;
Hemorrhagic Disorders
;
Humans
;
Lower Extremity
;
Lupus Coagulation Inhibitor
;
Lupus Erythematosus, Systemic*
;
Partial Thromboplastin Time
;
Platelet Count
;
Prednisolone
;
Prothrombin Time
;
Ulcer
10.Validation of the Korean Version of the Scale for Outcomes in Parkinson's Disease-Autonomic.
Ji Young KIM ; In Uk SONG ; Seong Beom KOH ; Tae Beom AHN ; Sang Jin KIM ; Sang Myung CHEON ; Jin Whan CHO ; Yun Joong KIM ; Hyeo Il MA ; Mee Young PARK ; Jong Sam BAIK ; Phil Hyu LEE ; Sun Ju CHUNG ; Jong Min KIM ; Han Joon KIM ; Young Hee SUNG ; Do Young KWON ; Jae Hyeok LEE ; Jee Young LEE ; Ji Sun KIM ; Ji Young YUN ; Hee Jin KIM ; Jin Young HONG ; Mi Jung KIM ; Jinyoung YOUN ; Ji Seon KIM ; Eung Seok OH ; Hui Jun YANG ; Won Tae YOON ; Sooyeoun YOU ; Kyum Yil KWON ; Hyung Eun PARK ; Su Yun LEE ; Younsoo KIM ; Hee Tae KIM ; Joong Seok KIM
Journal of Movement Disorders 2017;10(1):29-34
OBJECTIVE: Autonomic symptoms are commonly observed in patients with Parkinson's disease (PD) and often limit the activities of daily living. The Scale for Outcomes in Parkinson's disease-Autonomic (SCOPA-AUT) was developed to evaluate and quantify autonomic symptoms in PD. The goal of this study was to translate the original SCOPA-AUT, which was written in English, into Korean and to evaluate its reliability and validity for Korean PD patients. METHODS: For the translation, the following processes were performed: forward translation, backward translation, expert review, pretest of the pre-final version and development of the final Korean version of SCOPA-AUT (K-SCOPA-AUT). In total, 127 patients with PD from 31 movement disorder clinics of university-affiliated hospitals in Korea were enrolled in this study. All patients were assessed using the K-SCOPA-AUT and other motor, non-motor, and quality of life scores. Test-retest reliability for the K-SCOPA-AUT was assessed over a time interval of 10−14 days. RESULTS: The internal consistency and reliability of the K-SCOPA-AUT was 0.727 as measured by the mean Cronbach's α-coefficient. The test-retest correlation reliability was 0.859 by the Guttman split-half coefficient. The total K-SCOPA-AUT score showed a positive correlation with other non-motor symptoms [the Korean version of non-motor symptom scale (K-NMSS)], activities of daily living (Unified Parkinson's Disease Rating Scale part II) and quality of life [the Korean version of Parkinson's Disease Quality of Life 39 (K-PDQ39)]. CONCLUSION: The K-SCOPA-AUT had good reliability and validity for the assessment of autonomic dysfunction in Korean PD patients. Autonomic symptom severities were associated with many other motor and non-motor impairments and influenced quality of life.
Activities of Daily Living
;
Humans
;
Korea
;
Movement Disorders
;
Parkinson Disease
;
Quality of Life
;
Reproducibility of Results

Result Analysis
Print
Save
E-mail