1.Adrenocortical Carcinoma, Myxoid Variant: A Case Report.
Bomi KIM ; Sun Och YOON ; Dong Il KIM ; Myung Cherl KOOK ; Eun Kyung HONG
Korean Journal of Pathology 2007;41(6):430-435
Myxoid variant of adrenal cortical carcinoma is extremely rare and there have been only 16 such cases reported in the medical literature. Here we report on a case of 43-year-old woman with a left adrenal mass that was detected during the evaluation for Cushing's syndrome. Left adrenalectomy was performed and the tumor weighed 347 g. The cut surface was predominantly myxoid and gelatinous with central hemorrhage and necrosis. Histologically, the tumor cells were rather small, uniform and polygonal with mild pleomorphism. It showed diverse morphologic patterns according to the amount of the myxoid stromal component. Making the diagnosis was not easy because the tumor was without areas of conventional adrenocortical carcinoma. Immunohistochemically, the tumor cells were positive for alpha-inhibin, synaptophysin and vimentin, but the tumor cells were negative for pan-cytokeratin and CAM 5.2. The immunophenotypes were identical to those of conventional adrenal cortical neoplasms. During the evaluation of a cytokeratin-negative and vimentin-positive retroperitoneal neoplasm with a myxoid component, the possibility of adrenal cortical tumor should be considered in spite that this is a very rare entity.
Adrenalectomy
;
Adrenocortical Carcinoma*
;
Adult
;
Cushing Syndrome
;
Diagnosis
;
Female
;
Gelatin
;
Hemorrhage
;
Humans
;
Necrosis
;
Retroperitoneal Neoplasms
;
Synaptophysin
;
Vimentin
2.An Experimental Study on the Influence of New Spiral Stent(Hanaro) on the Vascular Structures.
Myung Kwan LIM ; Jae Hyung PARK ; Jin Wook CHUNG ; Yoong Ki JEONG ; Myeong Cherl KOOK ; Jung Wook SEO
Journal of the Korean Radiological Society 1996;34(6):745-756
PURPOSE: The purpose of this study was to evaluate basic experimental data for the clinical application of a self-expandable stainless steel intravascular Hanaro spiral stent. MATERIALS AND METHODS: For evaluation of thephysical properties of the Hanaro stent, hoop strength, radioopacity, longitudinal flexibility, and foreshortening were measured. Twelve intravascular Hanaro spiral stents were placed in the infrarenal abdominal aorta (n=6) and comon iliac artery (n=6) in six mongrel dogs. Angiography and light microscopic examination were performed after one, two and eight months of placement of the stents. RESULTS: The stent had good radioopacity and was deployed with minimal foreshortening. Hoop strength of a 6mm-interval bend was found to be superior to that of 8mm- and 10mm-bend stent. On angiography the patency rate and thrombosis rate were 100% and 0% in the abdominal aorta and 50% and 50% in the common iliac artery, respectively. Minimal corrosion was seen in all stents, and they appearedto be biocompatible. The stent wires were covered with well-developed neointima which after one month had mostly fibroblast and collagen tissue; the thickness of the neointima increased gradually during a period of eightmonths. At the end of that period, collagen fibres in the neointima were denser and showed a more paralled configuration than at one month. CONCLUSION: The Hanaro stent has good physical properties and also has a high patency rate, and good biocompatibilities. The stent may therefore be reliably and safely deployed in the humanvascular system.
Angiography
;
Animals
;
Aorta, Abdominal
;
Atherosclerosis
;
Collagen
;
Corrosion
;
Dogs
;
Iliac Artery
;
Neointima
;
Pliability
;
Stainless Steel
;
Stents
;
Thrombosis