1.Study of repuirements and conditions to be improved for voluntary occupational health program in worksite.
Jae Seok SONG ; Jong Uk WON ; Myong Sei SON ; Bong Suk CHA ; Jae Hoon ROH
Korean Journal of Preventive Medicine 1997;30(4):840-851
To perform voluntary occupational health program in worksites, regulational supports are necessary. The regulational supports include assessment of current occupational health program and appropriate incentives. The purpose of this study is to find out the requirements of voluntary occupational health program and conditions to be improved. Study population was industrial health managers of both industries with less than 300 workers and over 300 workers, and the member of labor union who is responsible for safety and health in worksite. Two different questionnaire were used to find out the requirements and conditions to be improved respectively. The results were; 1. The category which prevalence rate of occupational injuries and occupational disease should be lower than national average was most important in health managers employed in industries over 300 workers and followed by reporting system, education, worksite policy, work environment assessment, protective equipment, consequently. But those employed in industries less than 300 workers showed high importance in prevalence rate of occupational injuries and disease, reporting system, worksite policy, work environment assessment, protective equipment, education, consequently. 2. The members of labor union thought that worksite policy was most important and the next is education, reporting system, work environment assessment, protective equipment, prevalence rate of occupational injuries and disease. 3. There were difference in importance of education and worksite policy according to the size of industries. Reporting system, prevalence rate of occupational injuries and disease, and worksite policy had different importance between members of labor union and health managers. 4. In the results of questionnaire for conditions to be improved, the most important condition was top manager's willingness except personal protective equipments, and followed by financial support, legal support. The limitations of this study were the problems of representativeness of study population. but voluntary health program should be performed in worksites which have relatively good occupational health system. So, this selection bias could not disrupt our results.
Education
;
Financial Support
;
Humans
;
Labor Unions
;
Motivation
;
Occupational Diseases
;
Occupational Health*
;
Occupational Injuries
;
Prevalence
;
Surveys and Questionnaires
;
Selection Bias
;
Workplace*
2.Trend analysis of process quality indicators for the Korean National Cervical Cancer Screening Program from 2005 to 2013
Cam Nhung BUI ; Eunji CHOI ; Mina SUH ; Jae Kwan JUN ; Kyu Won JUNG ; Myong Cheol LIM ; Kui Son CHOI
Journal of Gynecologic Oncology 2021;32(1):e14-
Objective:
This study sought to examine changes in trends for quality indicators of the population-based Korean National Cancer Screening Program (KNCSP) for cervical cancer from years 2005 to 2013.
Methods:
Our study data were derived from the KNCSP database. Cervical cancer diagnosis information was ascertained through linkage with the Korean National Cancer Registry and the KNCSP database. Performance measures for cervical cancer screening were estimated, including participation rate, positive rate, crude detection rate (CDR), interval cancer rate (ICR), positive predictive value (PPV), sensitivity, and specificity. Joinpoint analysis was applied to calculate annual percentage changes (APCs) in all indicators according to sociodemographic factors.
Results:
A significant increasing trend was noted in participation rates (APC=13.4%; 95% confidence interval [CI]=10.5, 16.4). PPV and specificity increased from years 2005 to 2009 and remained stable till 2013. An increasing trend was discovered in CDRs for cervical cancer in situ (APC=3.9%; 95% CI=1.0, 6.9), whereas a decreasing trend was observed in ICRs for invasive cervical cancer (APC=−2.5%; 95% CI=−4.5, −0.5). Medical Aid recipients and women older than 70 years showed the lowest participation rates, but higher CDRs and ICRs, compared to other groups. In general, most of the quality indicators for cervical cancer screening improved from 2005 to 2009 and remained stable to 2013.
Conclusion
The KNCSP for cervical cancer in Korea has improved in terms of participation rate and accuracy of the screening test. These results may be attributed to the National Quality Improvement Program for KNCSP.
3.Effect of Pap smear screening on cervical cancer stage at diagnosis: results from the Korean National Cancer Screening Program
Cam Nhung BUI ; Seri HONG ; Mina SUH ; Jae Kwan JUN ; Kyu Won JUNG ; Myong Cheol LIM ; Kui Son CHOI
Journal of Gynecologic Oncology 2021;32(5):e81-
Objective:
We aimed to determine the differences in stage at diagnosis of cervical cancer among Korean women according to screening history.
Methods:
Using linkage data from the Korean Central Cancer Registry and Korean National Cancer Screening Program (KNCSP), we included 18,388 women older than 30 years who were newly diagnosed with cervical cancer between 2013 and 2014 and examined their screening history. Between individuals, age group and socioeconomic status were matched to control for potential confounders.
Results:
Significantly more cases of carcinoma in situ (CIS) were diagnosed in the ever-screened (71.77%) group than in the never-screened group (54.78%), while localized, regional, distant, and unknown stage were more frequent in the never-screened group. Women in the ever-screened group were most likely to be diagnosed with CIS than with invasive cervical cancer (adjusted odds ratio [aOR]=2.40; 95% confidence interval [CI]=2.18–2.65). The aOR for being diagnosed with CIS was highest among women who were screened 3 times or more (aOR=5.10; 95% CI=4.03–6.45). The ORs were highest for women screened within 24 months of diagnosis and tended to decrease with an increasing time since last screening (p-trend <0.01).
Conclusion
The KNCSP for cervical cancer was found to be positively associated with diagnosis of cervical cancers at earlier stages among women aged 30 years or older. The benefit of screening according to time was highest for women screened within 24 months of diagnosis.
4.Appendiceal mucocele masquerading as an epithelial borderline ovarian tumor: a case report and literature review
Young Joo KIM ; Jong Hyuk YUN ; Sung Hoon HONG ; GeumJong SONG ; Jong Eun LEE ; Myong Won SON ; Sun Wook HAN ; Sung Yong KIM ; Moon-Soo LEE
Korean Journal of Clinical Oncology 2022;18(2):83-88
Appendiceal mucocele is a rare mucin-producing neoplasm of appendiceal origin. Due to its location and imaging findings, appendiceal mucocele is easily confused with tumors of the right adnexa. We present a rare case of a patient initially misdiagnosed with an ovarian tumor intraoperatively diagnosed as an appendiceal mucocele and successfully treated. A 66-year-old postmenopausal woman was admitted to the gynecology department for an asymptomatic pelvic mass. Preoperative pelvic imaging showed an 8-cm cystic mass. Exploratory laparoscopy for the suspected epithelial borderline tumor from the right ovary revealed a cystic mass in the right pelvic area and normal uterus, fallopian tubes, and ovaries. Intraoperative consultation with the general surgery department confirmed the appendiceal origin. Laparoscopic appendectomy was performed. Histopathological examination confirmed a low-grade mucinous neoplasm of appendiceal origin. The patient was discharged on a postoperative day 5 without complications. The outpatient follow-up performed 1 month later showed no evidence of disease progression. Despite the use of advanced diagnostic tools, appendiceal mucocele may be confused for ovarian malignancies. Because the clinical features of appendiceal mucocele are nonspecific, clinicians and radiologists know the specific imaging findings. A multidisciplinary approach including general surgery, gynecology, and radiology is required for preoperative diagnosis and treatment.
5.Annual Report on External Quality Assessment in Immunoserology in Korea (2002).
Young Joo CHA ; Dong Gil KUM ; Sung Won KIM ; Think You KIM ; Jae Ryong KIM ; Hyon Suk KIM ; Myong Hee PARK ; Seong Hoon PARK ; Ae Ja PARK ; Han Chul SON ; Joo Suk YANG ; Kye Sook LEE ; Seok Lae CHAE
Journal of Laboratory Medicine and Quality Assurance 2003;25(1):51-71
The followings are the results for external quality assessment (EQA) in immunoserology for 2002: 1. Evaluation of EQA was done in 2 trials in May and November, about 96% of laboratories participating average 8.3 items. 2. In C-reactive protein (CRP), rheumatoid factor (RF) and anti-streptolysin O (ASO) tests, about 40%, 53% and 52% of the participating laboratories respectively have used qualitative assays, mainly latex agglutination. And about 55%, 43% and 40% of the participating laboratories have used quantitative assays, turbidimetric immunoassay (TIA) or nephelometry in CRP, RF and ASO tests respectively. Laboratories using TIA increased and those using nephelometry decreased. The instruments which were the most frequently used in nephelometry were BN series (Dade Behring Inc., Germany). The instruments of Hitachi series (Hitachi Ltd., Japan), Cobas Integra and Mira series (Roche Diagnostics GmbH, Germany), Toshiba series (Toshiba Corporation, Japan) and Olympus AU series (Olympus Optical Co., Ltd., Japan) were frequently used in TIA. The quantitative results were quite variable according to the methods or reagents, especially in RF and ASO. 3. Over 90% of participating laboratoreis have used imunoassay including enzyme immunoassay (EIA), microparticle EIA (MEIA), chemiluminescence immunoassay (CIA), immunochromatography assay (ICA) or radioimmunoassay (RIA). Laboratories using CIA and ICA increased. Sensitivities of ICA were lower than those of other immunoassays in the results of HBsAg and anti-HCV. The sensitivity of SD HCV (Standard Diagnostics, Inc., Korea) was especially lower in anti-HCV results. Sensitivities of CIA and ICA were also lower than those of EIA including MEIA in the results of anti-HIV. 4. The criteria of interpretation were considered to be evaluated in Widal test and laboratories using ICA increased in serological tests for syphilis.
Agglutination
;
C-Reactive Protein
;
Hepatitis B Surface Antigens
;
Immunoassay
;
Immunochromatography
;
Immunoenzyme Techniques
;
Indicators and Reagents
;
Korea*
;
Latex
;
Luminescence
;
Nephelometry and Turbidimetry
;
Radioimmunoassay
;
Rheumatoid Factor
;
Serologic Tests
;
Syphilis
6.Annual Report on External Quality Assessment in Immunoserology in Korea (2004).
Young Joo CHA ; So Yong KWON ; Dong Gil KUM ; Sung Won KIM ; Think You KIM ; Jae Ryong KIM ; Hyon Suk KIM ; Myong Hee PARK ; Seong Hoon PARK ; Ae Ja PARK ; Han Chul SON ; Joo Suk YANG ; Kye Sook LEE ; Seok Lae CHAE
Journal of Laboratory Medicine and Quality Assurance 2005;27(1):37-57
The followings are the results for external quality assessment (EQA) in immunoserology for 2004: 1. Evaluation of EQA was done in 2 trials in May and November, about 99% of laboratories participating average 8.4 items. EQA for anti-HBc test was newly started in 2004. 2. Commercial control, MASR Immunology Control from Medical Analysis Systems (Camarillo, CA, USA) was used to assure the quality of quantitative results of C-reactive protein (CRP), rheumatoid factor (RF) and anti-streptolysin O (ASO) tests in 2004. All the specimens for Immunoserology in EQA were delivered refrigerated for the first time, being received within 48 hours after sending. 3. EQA for detection of HBsAg mutants was tried for the first time, using the recombinant HBsAg mutant (Gly/Arg 145) kindly provided by Abbott Laboratories, USA. 4. The laboratories using immunochromatography assay (ICA) were increased, however, many laboratories using ICA reported falsely negative for the positive specimens. The sensitivity of ICA test kits as well as various factors influencing the ICA results should be evaluated. 5. Standardization of methods including calibrators for quantitative results should be required for the harmonization of results.
Allergy and Immunology
;
C-Reactive Protein
;
Hepatitis B Surface Antigens
;
Immunochromatography
;
Korea*
;
Nephelometry and Turbidimetry
;
Rheumatoid Factor
7.Annual Report on External Quality Assessment in Immunoserology in Korea (2003).
Young Joo CHA ; So Yong KWON ; Dong Gil KUM ; Sung Won KIM ; Think You KIM ; Jae Ryong KIM ; Hyon Suk KIM ; Myong Hee PARK ; Seong Hoon PARK ; Ae Ja PARK ; Han Chul SON ; Joo Suk YANG ; Kye Sook LEE ; Seok Lae CHAE
Journal of Laboratory Medicine and Quality Assurance 2004;26(1):47-69
The followings are the results for external quality assessment (EQA) in immunoserology for 2003: 1.Evaluation of EQA was done in 2 trials in May and November, about 99% of laboratories participating average 8.2 items. 2.In C-reactive protein (CRP), rheumatoid factor (RF) and anti-streptolysin O (ASO) tests, about 63%, 49% and 44% of the participating laboratories respectively have used quantitative assays. Because the laboratories using quanitiative assays were on the increase annually, commercial control, Liquicheck(TM) Immunology Contol from Bio-Rad Laboratories (Irvine, CA, USA) was used to assure the quality of quantitiavie results in 2003. A few laboratories reproted the outlier results, comparing with the reference ranges presented by the company. 3.Over 92% of participating laboratoreis have used imunoassays including enzyme immunoassay (EIA), microparticle EIA (MEIA), chemiluminescence immunoassay (CIA), immunochromatography assay (ICA) or radioimmunoassay (RIA) for detedting viral antigens or antibodies. Especially for anti-HCV, over 98% of participating laboratoreis have used various kind of imunoassays. Laboratories using ICA increased and about 24% of participating laboratoreis have used ICA for anti-HCV and anti-HIV. However, many laboratories using ICA for detecting anti-HCV reported false negative results, suggesting lower sensitivity of ICA than those of other immunoassays. 4.The criteria of interpretation were considered to be evaluated in Widal test and laboratories using ICA increased in serological tests for syphilis.
Allergy and Immunology
;
Antibodies
;
Antigens, Viral
;
C-Reactive Protein
;
Hepatitis B Surface Antigens
;
Immunoassay
;
Immunochromatography
;
Immunoenzyme Techniques
;
Korea*
;
Luminescence
;
Nephelometry and Turbidimetry
;
Radioimmunoassay
;
Reference Values
;
Rheumatoid Factor
;
Serologic Tests
;
Syphilis